Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAM72D30-540/MB — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM72D30-540/MB is a 540.0 W STC (506.8 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.43% efficiency, 49.6 V Voc at 25 C, and 54.13 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
540.0 W
PTC Wattage
506.8 W
Voc @ 25C
49.6 V
Efficiency
21.43%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM72D30-540/MB Compare Against Peer CEC Listings?

Engineering position of JA Solar JAM72D30-540/MB (540.0 W STC) vs. Apollo Renewables Inc Apollo-M772BH-540TW across 5,889 CEC Mono-c-Si solar modules.

Ranking #3,265 across 21,677 CEC solar panels (top 16.3%; higher than 83.7% of peers), JA Solar JAM72D30-540/MB operates as a large-format commercial and ground-mount module sitting 130.0 W above the 410.0 W Mono-c-Si median. Higher 49.6 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677), 15 panels occupy 407 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does JA Solar JAM72D30-540/MB Fall Across Listed CEC Models?

Plots JA Solar JAM72D30-540/MB at 540.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM72D30-540/MB (540.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM72D30-: 540.0 W

What Dataset Percentiles Define JA Solar JAM72D30-540/MB?

Benchmarks JA Solar JAM72D30-540/MB on STC wattage, thermal PTC/STC retention, and 21.43 aperture conversion efficiency against CEC peers.

JA Solar JAM72D30-540/MB Engineering BenchmarksPercentile comparison of JA Solar JAM72D30-540/MB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage540.0 WPTC/STC Retention93.9%Module Efficiency21.43%

What Do the Dataset Ranks Show for JA Solar JAM72D30-540/MB?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM72D30-540/MB by JA Solar.

Rank #3,265 / 21,677

Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,675

21.43% Aperture Efficiency

Power density 214.3 W/m2 (1.52 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.13 V at -10 C (595.4 V string) and 55.43 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,100 W STC

Occupies 37.8 m2 (407 sq ft) producing 7,602 W PTC; NEC 690.8 OCPD floor is 21.62 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.6 * (1 + (-0.261/100) * (-10 - 25)) = 54.13 V | OCPD = 1.56 * 13.86 = 21.62 A

Inputs from CEC Modules.csv for JA Solar JAM72D30-540/MB: Voc=49.6 V, beta_Voc=-0.261%/C, Isc=13.86 A, STC=540.0 W, Area=2.52 m2.

Result: 11 panels max on 600 V (595.4 V); 15 panels for 8 kW (407 sq ft).

What Are the Published CEC Specifications for JA Solar JAM72D30-540/MB?

Laboratory test ratings recorded for JA Solar JAM72D30-540/MB (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM72D30-540/MB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 540.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 506.8 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.86 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.64 V / 12.97 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.261 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.43% (2.52 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many JA Solar JAM72D30-540/MB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (407 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM72D30-540/MB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.48 kW 326 sq ft $1,622 $2,742
8 kW Class 15 8.1 kW 407 sq ft $2,027 $3,428
10 kW Class 19 10.26 kW 515 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAM72D30-540/MB under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAM72D30-540/MB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM72D30-530/MB 530.0 W 497.2 W 49.3 V 41.31 V 21.03%
JA Solar JAM72D30-535/MB 535.0 W 502.0 W 49.45 V 41.47 V 21.23%
JA Solar JAM72D30-540/MB 540.0 W 506.8 W 49.6 V 41.64 V 21.43%
JA Solar JAM72D30-545/MB 545.0 W 511.6 W 49.75 V 41.8 V 21.63%

How Many JA Solar JAM72D30-540/MB Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAM72D30-540/MB (beta_Voc -0.261%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.6V and beta_Voc=-0.261%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.43 V 10 panels 554.3 V 18 panels
-10 C (14 F) 54.13 V 11 panels 595.4 V 18 panels
0 C (32 F) 52.84 V 11 panels 581.2 V 18 panels
25 C (77 F STC) 49.6 V 12 panels 595.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72D30-540/MB?

Closest cross-brand CEC competitors to JA Solar JAM72D30-540/MB matched near 540.0 W STC and 49.6 V Voc, led by Apollo Renewables Inc Apollo-M772BH-540TW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Apollo Renewables Inc Apollo-M772BH-540TW
Apollo Renewables Inc
540.0 W Tie (0 W) 49.6 V 21.09% 93.5%
AXITEC AC-540MBT/144V
AXITEC
540.0 W Tie (0 W) 49.6 V 21.09% 93.5%
AXITEC AC-540MBT/144VB
AXITEC
540.0 W Tie (0 W) 49.6 V 21.09% 93.5%
ELITE Solar ET-M772BH540TB
ELITE Solar
540.0 W Tie (0 W) 49.6 V 21.09% 93.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM72D30-540/MB?

Evaluate JA Solar JAM72D30-540/MB (540.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72D30-540/MB reaches 55.43 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 407 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM72D30-540/MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM72D30-540/MB 8 kW Residential Fit

Needs 15 modules (407 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Apollo Renewables Inc Apollo-M772BH-540TW.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 506.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM72D30-540/MB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAM72D30-540/MB panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM72D30-540/MB cold Voc rises from 49.6 V to 54.13 V (beta_Voc -0.261%/C), capping a 600 V string at 11 panels (595.4 V).

How much roof area does an 8 kW array of JA Solar JAM72D30-540/MB need?

An 8 kW DC system uses 15 JA Solar JAM72D30-540/MB modules (8,100 W STC / 7,602 W PTC), covering roughly 407 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does JA Solar JAM72D30-540/MB compare against Apollo Renewables Inc Apollo-M772BH-540TW?

JA Solar JAM72D30-540/MB outputs 540.0 W STC (49.6 V Voc, rank #3,265 of 21,677), while Apollo Renewables Inc Apollo-M772BH-540TW delivers 540.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.