AXITEC AC-540MBT/144VB is a 540.0 W STC (505.0 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.09% efficiency, 49.6 V Voc at 25 C, and 54.58 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 540.0 W
- PTC Wattage
- 505.0 W
- Voc @ 25C
- 49.6 V
- Efficiency
- 21.09%
How Does AXITEC AC-540MBT/144VB Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-540MBT/144VB (Mono-c-Si) residential solar systems.
AXITEC AC-540MBT/144VB delivers 210.9 W/m2 (1.18 percentage points above 19.91% CEC median) and strong 93.5% PTC-to-STC heat retention (#7,159 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 56.01 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Apollo Renewables Inc Apollo-M772BH-540TW (540.0 W).
Where Does AXITEC AC-540MBT/144VB Fall Across Listed CEC Models?
Comparison of AXITEC AC-540MBT/144VB (540.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Dataset Percentiles Define AXITEC AC-540MBT/144VB?
Relative ranking of AXITEC AC-540MBT/144VB across nameplate watts, 93.5% PTC thermal ratio, and module aperture efficiency. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for AXITEC AC-540MBT/144VB?
Summary of AXITEC AC-540MBT/144VB output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.
Top 16.3% STC Output
540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.09% Aperture Efficiency
Power density 210.9 W/m2 (1.18 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.58 V at -10 C (545.8 V string) and 56.01 V at -20 C (10 max).
15 Panels = 8,100 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,575 W PTC; NEC 690.8 OCPD floor is 21.62 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.6 * (1 + (-0.287/100) * (-10 - 25)) = 54.58 V | OCPD = 1.56 * 13.86 = 21.62 A
Inputs from CEC Modules.csv for AXITEC AC-540MBT/144VB: Voc=49.6 V, beta_Voc=-0.287%/C, Isc=13.86 A, STC=540.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (545.8 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for AXITEC AC-540MBT/144VB?
Complete CEC test sheet for AXITEC AC-540MBT/144VB including Isc (13.86 A), Voc (49.6 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 540.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 505.0 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.86 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.64 V / 12.97 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.287 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.09% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many AXITEC AC-540MBT/144VB Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-540MBT/144VB.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.48 kW | 331 sq ft | $1,622 | $2,742 |
| 8 kW Class | 15 | 8.1 kW | 413 sq ft | $2,027 | $3,428 |
| 10 kW Class | 19 | 10.26 kW | 524 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Related AXITEC power steps and black/silver trims consolidated into this AXITEC AC-540MBT/144VB series guide. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-530MBT/144VB | 530.0 W | 495.4 W | 49.3 V | 41.31 V | 20.7% |
| AXITEC AC-535MBT/144VB | 535.0 W | 500.2 W | 49.45 V | 41.47 V | 20.9% |
| AXITEC AC-540MBT/144VB | 540.0 W | 505.0 W | 49.6 V | 41.64 V | 21.09% |
| AXITEC AC-545MBT/144VB | 545.0 W | 509.8 W | 49.75 V | 41.8 V | 21.29% |
How Many AXITEC AC-540MBT/144VB Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for AXITEC AC-540MBT/144VB (49.6 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.01 V | 10 panels | 560.1 V | 17 panels |
| -10 C (14 F) | 54.58 V | 10 panels | 545.8 V | 18 panels |
| 0 C (32 F) | 53.16 V | 11 panels | 584.8 V | 18 panels |
| 25 C (77 F STC) | 49.6 V | 12 panels | 595.2 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-540MBT/144VB?
Four comparable CEC modules such as Apollo Renewables Inc Apollo-M772BH-540TW (540.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Apollo Renewables Inc Apollo-M772BH-540TW Apollo Renewables Inc |
540.0 W | Tie (0 W) | 49.6 V | 21.09% | 93.5% |
| ELITE Solar ET-M772BH540TB ELITE Solar |
540.0 W | Tie (0 W) | 49.6 V | 21.09% | 93.5% |
| ELITE Solar ET-M772BH540TW ELITE Solar |
540.0 W | Tie (0 W) | 49.6 V | 21.09% | 93.5% |
| JA Solar JAM72D30-540/MB JA Solar |
540.0 W | Tie (0 W) | 49.6 V | 21.43% | 93.9% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-540MBT/144VB?
Evaluate AXITEC AC-540MBT/144VB (540.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-540MBT/144VB reaches 56.01 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of AXITEC AC-540MBT/144VB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-540MBT/144VB 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Apollo Renewables Inc Apollo-M772BH-540TW.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 505.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-540MBT/144VB by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many AXITEC AC-540MBT/144VB panels fit on a 600 V winter solar string?
At -10 C (14 F), AXITEC AC-540MBT/144VB cold Voc rises from 49.6 V to 54.58 V (beta_Voc -0.287%/C), capping a 600 V string at 10 panels (545.8 V).
How much roof area does an 8 kW array of AXITEC AC-540MBT/144VB need?
An 8 kW DC system uses 15 AXITEC AC-540MBT/144VB modules (8,100 W STC / 7,575 W PTC), covering roughly 413 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does AXITEC AC-540MBT/144VB compare against Apollo Renewables Inc Apollo-M772BH-540TW?
AXITEC AC-540MBT/144VB outputs 540.0 W STC (49.6 V Voc, rank #3,265 of 21,677), while Apollo Renewables Inc Apollo-M772BH-540TW delivers 540.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)