Skip to main content
WireAndSun
Calculators
CEC PV Module

AXITEC AC-540MBT/144VB — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-540MBT/144VB is a 540.0 W STC (505.0 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.09% efficiency, 49.6 V Voc at 25 C, and 54.58 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
540.0 W
PTC Wattage
505.0 W
Voc @ 25C
49.6 V
Efficiency
21.09%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-540MBT/144VB Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-540MBT/144VB (Mono-c-Si) residential solar systems.

AXITEC AC-540MBT/144VB delivers 210.9 W/m2 (1.18 percentage points above 19.91% CEC median) and strong 93.5% PTC-to-STC heat retention (#7,159 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 56.01 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with Apollo Renewables Inc Apollo-M772BH-540TW (540.0 W).

Where Does AXITEC AC-540MBT/144VB Fall Across Listed CEC Models?

Comparison of AXITEC AC-540MBT/144VB (540.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-540MBT/144VB (540.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-540MBT/1: 540.0 W

What Dataset Percentiles Define AXITEC AC-540MBT/144VB?

Relative ranking of AXITEC AC-540MBT/144VB across nameplate watts, 93.5% PTC thermal ratio, and module aperture efficiency. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

AXITEC AC-540MBT/144VB Engineering BenchmarksPercentile comparison of AXITEC AC-540MBT/144VB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage540.0 WPTC/STC Retention93.5%Module Efficiency21.09%

What Do the Dataset Ranks Show for AXITEC AC-540MBT/144VB?

Summary of AXITEC AC-540MBT/144VB output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #3,265 / 21,677

Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,965

21.09% Aperture Efficiency

Power density 210.9 W/m2 (1.18 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.58 V at -10 C (545.8 V string) and 56.01 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,100 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,575 W PTC; NEC 690.8 OCPD floor is 21.62 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.6 * (1 + (-0.287/100) * (-10 - 25)) = 54.58 V | OCPD = 1.56 * 13.86 = 21.62 A

Inputs from CEC Modules.csv for AXITEC AC-540MBT/144VB: Voc=49.6 V, beta_Voc=-0.287%/C, Isc=13.86 A, STC=540.0 W, Area=2.56 m2.

Result: 10 panels max on 600 V (545.8 V); 15 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for AXITEC AC-540MBT/144VB?

Complete CEC test sheet for AXITEC AC-540MBT/144VB including Isc (13.86 A), Voc (49.6 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-540MBT/144VB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 540.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 505.0 W (93.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.86 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.64 V / 12.97 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.287 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.09% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many AXITEC AC-540MBT/144VB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-540MBT/144VB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.48 kW 331 sq ft $1,622 $2,742
8 kW Class 15 8.1 kW 413 sq ft $2,027 $3,428
10 kW Class 19 10.26 kW 524 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Related AXITEC power steps and black/silver trims consolidated into this AXITEC AC-540MBT/144VB series guide. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the AXITEC AC-540MBT/144VB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-530MBT/144VB 530.0 W 495.4 W 49.3 V 41.31 V 20.7%
AXITEC AC-535MBT/144VB 535.0 W 500.2 W 49.45 V 41.47 V 20.9%
AXITEC AC-540MBT/144VB 540.0 W 505.0 W 49.6 V 41.64 V 21.09%
AXITEC AC-545MBT/144VB 545.0 W 509.8 W 49.75 V 41.8 V 21.29%

How Many AXITEC AC-540MBT/144VB Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for AXITEC AC-540MBT/144VB (49.6 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=49.6V and beta_Voc=-0.287%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.01 V 10 panels 560.1 V 17 panels
-10 C (14 F) 54.58 V 10 panels 545.8 V 18 panels
0 C (32 F) 53.16 V 11 panels 584.8 V 18 panels
25 C (77 F STC) 49.6 V 12 panels 595.2 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-540MBT/144VB?

Four comparable CEC modules such as Apollo Renewables Inc Apollo-M772BH-540TW (540.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Apollo Renewables Inc Apollo-M772BH-540TW
Apollo Renewables Inc
540.0 W Tie (0 W) 49.6 V 21.09% 93.5%
ELITE Solar ET-M772BH540TB
ELITE Solar
540.0 W Tie (0 W) 49.6 V 21.09% 93.5%
ELITE Solar ET-M772BH540TW
ELITE Solar
540.0 W Tie (0 W) 49.6 V 21.09% 93.5%
JA Solar JAM72D30-540/MB
JA Solar
540.0 W Tie (0 W) 49.6 V 21.43% 93.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-540MBT/144VB?

Evaluate AXITEC AC-540MBT/144VB (540.0 W STC, 49.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-540MBT/144VB reaches 56.01 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-540MBT/144VB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-540MBT/144VB 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Apollo Renewables Inc Apollo-M772BH-540TW.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 505.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-540MBT/144VB by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

How many AXITEC AC-540MBT/144VB panels fit on a 600 V winter solar string?

At -10 C (14 F), AXITEC AC-540MBT/144VB cold Voc rises from 49.6 V to 54.58 V (beta_Voc -0.287%/C), capping a 600 V string at 10 panels (545.8 V).

How much roof area does an 8 kW array of AXITEC AC-540MBT/144VB need?

An 8 kW DC system uses 15 AXITEC AC-540MBT/144VB modules (8,100 W STC / 7,575 W PTC), covering roughly 413 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does AXITEC AC-540MBT/144VB compare against Apollo Renewables Inc Apollo-M772BH-540TW?

AXITEC AC-540MBT/144VB outputs 540.0 W STC (49.6 V Voc, rank #3,265 of 21,677), while Apollo Renewables Inc Apollo-M772BH-540TW delivers 540.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.