Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAM72D20-455/MB — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM72D20-455/MB is a 455.0 W STC (427.3 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 20.5% efficiency, 49.75 V Voc at 25 C, and 54.33 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
427.3 W
Voc @ 25C
49.75 V
Efficiency
20.5%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM72D20-455/MB Compare Against Peer CEC Listings?

Engineering position of JA Solar JAM72D20-455/MB (455.0 W STC) vs. Caterpillar Inc PVC455MB03H across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, JA Solar JAM72D20-455/MB pairs strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677) with 49.75 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,691 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Peer Caterpillar Inc PVC455MB03H offers a 455.0 W alternative.

Where Does JA Solar JAM72D20-455/MB Fall Across Listed CEC Models?

Plots JA Solar JAM72D20-455/MB at 455.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM72D20-455/MB (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM72D20-: 455.0 W

What Dataset Percentiles Define JA Solar JAM72D20-455/MB?

Benchmarks JA Solar JAM72D20-455/MB on STC wattage, thermal PTC/STC retention, and 20.5 aperture conversion efficiency against CEC peers.

JA Solar JAM72D20-455/MB Engineering BenchmarksPercentile comparison of JA Solar JAM72D20-455/MB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention93.9%Module Efficiency20.5%

What Do the Dataset Ranks Show for JA Solar JAM72D20-455/MB?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM72D20-455/MB by JA Solar.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,637

20.5% Aperture Efficiency

Power density 205.0 W/m2 (0.59 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.33 V at -10 C (597.6 V string) and 55.64 V at -20 C (10 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 40.0 m2 (430 sq ft) producing 7,691 W PTC; NEC 690.8 OCPD floor is 17.88 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.75 * (1 + (-0.263/100) * (-10 - 25)) = 54.33 V | OCPD = 1.56 * 11.46 = 17.88 A

Inputs from CEC Modules.csv for JA Solar JAM72D20-455/MB: Voc=49.75 V, beta_Voc=-0.263%/C, Isc=11.46 A, STC=455.0 W, Area=2.22 m2.

Result: 11 panels max on 600 V (597.6 V); 18 panels for 8 kW (430 sq ft).

What Are the Published CEC Specifications for JA Solar JAM72D20-455/MB?

Laboratory test ratings recorded for JA Solar JAM72D20-455/MB (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM72D20-455/MB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 427.3 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.75 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.46 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.52 V / 10.96 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.263 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.5% (2.22 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many JA Solar JAM72D20-455/MB Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (430 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM72D20-455/MB.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 335 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 430 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 526 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAM72D20-455/MB under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAM72D20-455/MB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM72D20-450/MB 450.0 W 422.5 W 49.61 V 41.21 V 20.27%
JA Solar JAM72D20-455/MB 455.0 W 427.3 W 49.75 V 41.52 V 20.5%
JA Solar JAM72D20-460/MB 460.0 W 432.1 W 49.91 V 41.79 V 20.72%

How Many JA Solar JAM72D20-455/MB Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAM72D20-455/MB (beta_Voc -0.263%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.75V and beta_Voc=-0.263%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.64 V 10 panels 556.4 V 17 panels
-10 C (14 F) 54.33 V 11 panels 597.6 V 18 panels
0 C (32 F) 53.02 V 11 panels 583.2 V 18 panels
25 C (77 F STC) 49.75 V 12 panels 597.0 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM72D20-455/MB?

Closest cross-brand CEC competitors to JA Solar JAM72D20-455/MB matched near 455.0 W STC and 49.75 V Voc, led by Caterpillar Inc PVC455MB03H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Caterpillar Inc PVC455MB03H
Caterpillar Inc
455.0 W Tie (0 W) 49.8 V 21.56% 93.8%
CSI Solar Co Ltd CS3W-455MB-AG
CSI Solar Co Ltd
455.0 W Tie (0 W) 49.3 V 21.06% 92.9%
Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF
Boviet Solar Technology Co Ltd
455.0 W Tie (0 W) 49.25 V 20.4% 93.8%
Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF-DG
Boviet Solar Technology Co Ltd
455.0 W Tie (0 W) 49.25 V 20.4% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM72D20-455/MB?

Evaluate JA Solar JAM72D20-455/MB (455.0 W STC, 49.75 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM72D20-455/MB reaches 55.64 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 430 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (430 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM72D20-455/MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM72D20-455/MB 8 kW Residential Fit

Needs 18 modules (430 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Caterpillar Inc PVC455MB03H.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 427.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM72D20-455/MB by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for JA Solar JAM72D20-455/MB?

Multiplying JA Solar JAM72D20-455/MB's 11.46 A short-circuit current by 1.56 equals 17.88 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can JA Solar JAM72D20-455/MB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 54.33 V cold Voc at 14 F and handles 11.46 A Isc; string inverters cap JA Solar JAM72D20-455/MB at 11 panels on 600 V.

Is JA Solar JAM72D20-455/MB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM72D20-455/MB rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.