Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM60S10-340/MR is a 340.0 W STC (315.4 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 20.86% efficiency, 41.55 V Voc at 25 C, and 45.32 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
340.0 W
PTC Wattage
315.4 W
Voc @ 25C
41.55 V
Efficiency
20.86%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM60S10-340/MR Compare Against Peer CEC Listings?

Engineering position of JA Solar JAM60S10-340/MR (340.0 W STC) vs. DualSun SAS DualSun 340M-120-00 across 5,889 CEC Mono-c-Si solar modules.

Ranking #13,575 across 21,677 CEC solar panels (below all-CEC median; higher than 36.1% of peers), JA Solar JAM60S10-340/MR operates as a compact residential or specialty off-grid module sitting 70.0 W below the 410.0 W Mono-c-Si median. Mid-range 41.55 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 92.8% PTC-to-STC heat retention (#10,898 of 21,677), 24 panels occupy 421 sq ft and offset roughly $2,042/yr at average US rates (or $3,454/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does JA Solar JAM60S10-340/MR Fall Across Listed CEC Models?

Plots JA Solar JAM60S10-340/MR at 340.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM60S10-340/MR (340.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM60S10-: 340.0 W

What Dataset Percentiles Define JA Solar JAM60S10-340/MR?

Benchmarks JA Solar JAM60S10-340/MR on STC wattage, thermal PTC/STC retention, and 20.86 aperture conversion efficiency against CEC peers.

JA Solar JAM60S10-340/MR Engineering BenchmarksPercentile comparison of JA Solar JAM60S10-340/MR wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage340.0 WPTC/STC Retention92.8%Module Efficiency20.86%

What Do the Dataset Ranks Show for JA Solar JAM60S10-340/MR?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM60S10-340/MR by JA Solar.

Rank #13,575 / 21,677

340.0 W STC · Higher Than 36.1%

340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,024

20.86% Aperture Efficiency

Power density 208.6 W/m2 (0.95 percentage points above 19.91% CEC median). PTC/STC ratio: 92.8% (rank #10,898).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.32 V at -10 C (589.2 V string) and 46.39 V at -20 C (12 max).

8 kW Reference Array

24 Panels = 8,160 W STC

Occupies 39.1 m2 (421 sq ft) producing 7,570 W PTC; NEC 690.8 OCPD floor is 16.32 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.55 * (1 + (-0.259/100) * (-10 - 25)) = 45.32 V | OCPD = 1.56 * 10.46 = 16.32 A

Inputs from CEC Modules.csv for JA Solar JAM60S10-340/MR: Voc=41.55 V, beta_Voc=-0.259%/C, Isc=10.46 A, STC=340.0 W, Area=1.63 m2.

Result: 13 panels max on 600 V (589.2 V); 24 panels for 8 kW (421 sq ft).

What Are the Published CEC Specifications for JA Solar JAM60S10-340/MR?

Laboratory test ratings recorded for JA Solar JAM60S10-340/MR (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM60S10-340/MR.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 340.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 315.4 W (92.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.55 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.46 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.73 V / 9.79 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.259 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.86% (1.63 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many JA Solar JAM60S10-340/MR Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (421 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM60S10-340/MR.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.12 kW 316 sq ft $1,532 $2,590
8 kW Class 24 8.16 kW 421 sq ft $2,042 $3,454
10 kW Class 30 10.2 kW 526 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAM60S10-340/MR under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAM60S10-340/MR wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM60S10-330/MR 330.0 W 305.9 W 41.08 V 34.24 V 20.25%
JA Solar JAM60S10-335/MR 335.0 W 310.7 W 41.32 V 34.48 V 20.55%
JA Solar JAM60S10-340/MR 340.0 W 315.4 W 41.55 V 34.73 V 20.86%
JA Solar JAM60S10-345/MR 345.0 W 320.2 W 41.76 V 34.99 V 21.17%

How Many JA Solar JAM60S10-340/MR Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAM60S10-340/MR (beta_Voc -0.259%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=41.55V and beta_Voc=-0.259%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.39 V 12 panels 556.7 V 21 panels
-10 C (14 F) 45.32 V 13 panels 589.2 V 22 panels
0 C (32 F) 44.24 V 13 panels 575.1 V 22 panels
25 C (77 F STC) 41.55 V 14 panels 581.7 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM60S10-340/MR?

Closest cross-brand CEC competitors to JA Solar JAM60S10-340/MR matched near 340.0 W STC and 41.55 V Voc, led by DualSun SAS DualSun 340M-120-00.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DualSun SAS DualSun 340M-120-00
DualSun SAS
340.0 W Tie (0 W) 40.1 V 18.78% 93.2%
Dehui Solar Power (Vietnam) CoLtd DH-M860F 335W
Dehui Solar Power (Vietnam) CoLtd
335.0 W -5.0 W 40.8 V 20.81% 93.0%
Auxin Solar AXNG1M335B
Auxin Solar
335.0 W -5.0 W 40.75 V 20.43% 93.2%
Dehui Solar Power (Vietnam) CoLtd DH-M860W 335W
Dehui Solar Power (Vietnam) CoLtd
335.0 W -5.0 W 40.7 V 21.07% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM60S10-340/MR?

Evaluate JA Solar JAM60S10-340/MR (340.0 W STC, 41.55 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM60S10-340/MR reaches 46.39 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 421 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (421 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM60S10-340/MR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM60S10-340/MR 8 kW Residential Fit

Needs 24 modules (421 sq ft) with a 20 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare DualSun SAS DualSun 340M-120-00.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 315.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM60S10-340/MR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many JA Solar JAM60S10-340/MR panels fit on a 600 V winter solar string?

At -10 C (14 F), JA Solar JAM60S10-340/MR cold Voc rises from 41.55 V to 45.32 V (beta_Voc -0.259%/C), capping a 600 V string at 13 panels (589.2 V).

How much roof area does an 8 kW array of JA Solar JAM60S10-340/MR need?

An 8 kW DC system uses 24 JA Solar JAM60S10-340/MR modules (8,160 W STC / 7,570 W PTC), covering roughly 421 sq ft and saving ~$2,042/yr at 18.54 c/kWh.

How does JA Solar JAM60S10-340/MR compare against DualSun SAS DualSun 340M-120-00?

JA Solar JAM60S10-340/MR outputs 340.0 W STC (41.55 V Voc, rank #13,575 of 21,677), while DualSun SAS DualSun 340M-120-00 delivers 340.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.