JA Solar JAM60S01-290/PR is a 290.0 W STC (268.1 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 18.32% efficiency, 39.46 V Voc at 25 C, and 43.34 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 290.0 W
- PTC Wattage
- 268.1 W
- Voc @ 25C
- 39.46 V
- Efficiency
- 18.32%
How Does JA Solar JAM60S01-290/PR Compare Against Peer CEC Listings?
Solar engineering breakdown for JA Solar JAM60S01-290/PR: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from JA Solar and peers, JA Solar JAM60S01-290/PR stands 120.0 W below the 410.0 W Mono-c-Si median and strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677). Sizing 6 kW (21 panels) to 10 kW (35 panels) yields $1,524-$2,540/yr in baseline US bill offset. Lower 39.46 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does JA Solar JAM60S01-290/PR Fall Across Listed CEC Models?
Distribution marker showing JA Solar JAM60S01-290/PR (290.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define JA Solar JAM60S01-290/PR?
Dataset percentiles tracking JA Solar JAM60S01-290/PR power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for JA Solar JAM60S01-290/PR?
Benchmark highlights for JA Solar JAM60S01-290/PR covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
290.0 W STC · Higher Than 18.8%
290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.32% Aperture Efficiency
Power density 183.2 W/m2 (1.59 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.34 V at -10 C (563.4 V string) and 44.45 V at -20 C (13 max).
28 Panels = 8,120 W STC
Occupies 44.3 m2 (477 sq ft) producing 7,507 W PTC; NEC 690.8 OCPD floor is 14.93 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.46 * (1 + (-0.281/100) * (-10 - 25)) = 43.34 V | OCPD = 1.56 * 9.57 = 14.93 A
Inputs from CEC Modules.csv for JA Solar JAM60S01-290/PR: Voc=39.46 V, beta_Voc=-0.281%/C, Isc=9.57 A, STC=290.0 W, Area=1.583 m2.
Result: 13 panels max on 600 V (563.4 V); 28 panels for 8 kW (477 sq ft).
What Are the Published CEC Specifications for JA Solar JAM60S01-290/PR?
Official CEC datasheet figures for JA Solar JAM60S01-290/PR (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 268.1 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.46 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.57 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.8 V / 9.12 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.281 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.32% (1.583 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM60S01-290/PR Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many JA Solar JAM60S01-290/PR modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.09 kW | 358 sq ft | $1,524 | $2,577 |
| 8 kW Class | 28 | 8.12 kW | 477 sq ft | $2,032 | $3,437 |
| 10 kW Class | 35 | 10.15 kW | 596 sq ft | $2,540 | $4,296 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Consolidated JA Solar wattage variants sharing the JA Solar JAM60S01-290/PR mechanical and cell layout. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM60S01-280/PR | 280.0 W | 258.7 W | 39.05 V | 31.6 V | 17.69% |
| JA Solar JAM60S01-285/PR | 285.0 W | 263.4 W | 39.25 V | 31.7 V | 18.0% |
| JA Solar JAM60S01-290/PR | 290.0 W | 268.1 W | 39.46 V | 31.8 V | 18.32% |
| JA Solar JAM60S01-295/PR | 295.0 W | 272.9 W | 39.64 V | 32.03 V | 18.64% |
How Many JA Solar JAM60S01-290/PR Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM60S01-290/PR (43.34 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.45 V | 13 panels | 577.9 V | 22 panels |
| -10 C (14 F) | 43.34 V | 13 panels | 563.4 V | 23 panels |
| 0 C (32 F) | 42.23 V | 14 panels | 591.2 V | 23 panels |
| 25 C (77 F STC) | 39.46 V | 15 panels | 591.9 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM60S01-290/PR?
Competing CEC solar panels closest to JA Solar JAM60S01-290/PR in nameplate wattage and Voc, starting with AXITEC AC-290M/60S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-290M/60S AXITEC |
290.0 W | Tie (0 W) | 39.42 V | 17.79% | 91.1% |
| AXITEC AC-290M/60V AXITEC |
290.0 W | Tie (0 W) | 39.42 V | 17.79% | 91.1% |
| DualSun SAS DualSun 290M-60-00 DualSun SAS |
290.0 W | Tie (0 W) | 39.7 V | 17.68% | 90.9% |
| CertainTeed CT290M10-02 CertainTeed |
290.0 W | Tie (0 W) | 39.77 V | 17.83% | 91.8% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM60S01-290/PR?
Evaluate JA Solar JAM60S01-290/PR (290.0 W STC, 39.46 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM60S01-290/PR reaches 44.45 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 477 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (477 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM60S01-290/PR carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM60S01-290/PR 8 kW Residential Fit
Needs 28 modules (477 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-290M/60S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 268.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM60S01-290/PR by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for JA Solar JAM60S01-290/PR?
Multiplying JA Solar JAM60S01-290/PR's 9.57 A short-circuit current by 1.56 equals 14.93 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can JA Solar JAM60S01-290/PR pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.34 V cold Voc at 14 F and handles 9.57 A Isc; string inverters cap JA Solar JAM60S01-290/PR at 13 panels on 600 V.
Is JA Solar JAM60S01-290/PR eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM60S01-290/PR rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)