JA Solar JAM6-60-280/SI is a 280.0 W STC (253.1 W PTC) Mono-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 17.12% efficiency, 38.86 V Voc at 25 C, and 43.08 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 280.0 W
- PTC Wattage
- 253.1 W
- Voc @ 25C
- 38.86 V
- Efficiency
- 17.12%
How Does JA Solar JAM6-60-280/SI Compare Against Peer CEC Listings?
Solar engineering breakdown for JA Solar JAM6-60-280/SI: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from JA Solar and peers, JA Solar JAM6-60-280/SI stands 130.0 W below the 410.0 W Mono-c-Si median and typical 90.4% PTC-to-STC thermal output (253.1 W real-world rating). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,542-$2,523/yr in baseline US bill offset. Lower 38.86 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does JA Solar JAM6-60-280/SI Fall Across Listed CEC Models?
Distribution marker showing JA Solar JAM6-60-280/SI (280.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define JA Solar JAM6-60-280/SI?
Dataset percentiles tracking JA Solar JAM6-60-280/SI power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for JA Solar JAM6-60-280/SI?
Benchmark highlights for JA Solar JAM6-60-280/SI covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
280.0 W STC · Higher Than 15.8%
280.0 W STC (-105.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.12% Aperture Efficiency
Power density 171.3 W/m2 (2.79 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.08 V at -10 C (560.0 V string) and 44.28 V at -20 C (13 max).
29 Panels = 8,120 W STC
Occupies 47.4 m2 (510 sq ft) producing 7,340 W PTC; NEC 690.8 OCPD floor is 14.46 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.86 * (1 + (-0.31/100) * (-10 - 25)) = 43.08 V | OCPD = 1.56 * 9.27 = 14.46 A
Inputs from CEC Modules.csv for JA Solar JAM6-60-280/SI: Voc=38.86 V, beta_Voc=-0.31%/C, Isc=9.27 A, STC=280.0 W, Area=1.635 m2.
Result: 13 panels max on 600 V (560.0 V); 29 panels for 8 kW (510 sq ft).
What Are the Published CEC Specifications for JA Solar JAM6-60-280/SI?
Official CEC datasheet figures for JA Solar JAM6-60-280/SI (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 280.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 253.1 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.86 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.27 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.82 V / 8.8 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.31 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.12% (1.635 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many JA Solar JAM6-60-280/SI Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many JA Solar JAM6-60-280/SI modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.16 kW | 387 sq ft | $1,542 | $2,607 |
| 8 kW Class | 29 | 8.12 kW | 510 sq ft | $2,032 | $3,437 |
| 10 kW Class | 36 | 10.08 kW | 634 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?
Consolidated JA Solar wattage variants sharing the JA Solar JAM6-60-280/SI mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| JA Solar JAM6-60-275/SI | 275.0 W | 248.5 W | 38.66 V | 31.58 V | 16.82% |
| JA Solar JAM6-60-280/SI | 280.0 W | 253.1 W | 38.86 V | 31.82 V | 17.12% |
How Many JA Solar JAM6-60-280/SI Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM6-60-280/SI (43.08 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.28 V | 13 panels | 575.6 V | 22 panels |
| -10 C (14 F) | 43.08 V | 13 panels | 560.0 V | 23 panels |
| 0 C (32 F) | 41.87 V | 14 panels | 586.2 V | 23 panels |
| 25 C (77 F STC) | 38.86 V | 15 panels | 582.9 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM6-60-280/SI?
Competing CEC solar panels closest to JA Solar JAM6-60-280/SI in nameplate wattage and Voc, starting with Centrosolar America TM6 280xx.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America TM6 280xx Centrosolar America |
280.0 W | Tie (0 W) | 38.7 V | 17.14% | 90.6% |
| Centrosolar America TM6S 280xx Centrosolar America |
280.0 W | Tie (0 W) | 38.7 V | 17.14% | 90.6% |
| GCL System Integration Technology Co Ltd GCL-M6/60280 GCL System Integration Technology Co Ltd |
280.0 W | Tie (0 W) | 38.7 V | 17.18% | 90.1% |
| GCL System Integration Technology Co Ltd GCL-P6/60280 GCL System Integration Technology Co Ltd |
280.0 W | Tie (0 W) | 38.7 V | 17.18% | 90.6% |
What Are the Design Limits and Best-Fit Uses for JA Solar JAM6-60-280/SI?
Evaluate JA Solar JAM6-60-280/SI (280.0 W STC, 38.86 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM6-60-280/SI reaches 44.28 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 29 panels for an 8 kW build require 510 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (510 sq ft).
- 2026 tax credit baseline: cash residential installs of JA Solar JAM6-60-280/SI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
JA Solar JAM6-60-280/SI 8 kW Residential Fit
Needs 29 modules (510 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TM6 280xx.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 253.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for JA Solar JAM6-60-280/SI by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for JA Solar JAM6-60-280/SI?
Multiplying JA Solar JAM6-60-280/SI's 9.27 A short-circuit current by 1.56 equals 14.46 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can JA Solar JAM6-60-280/SI pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.08 V cold Voc at 14 F and handles 9.27 A Isc; string inverters cap JA Solar JAM6-60-280/SI at 13 panels on 600 V.
Is JA Solar JAM6-60-280/SI eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM6-60-280/SI rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)