JA Solar JAM5(L)(BK)-72-205/SI — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM5(L)(BK)-72-205/SI is a 205.0 W STC (183.1 W PTC) Mono-c-Si solar module ranking #20,980 of 21,677 CEC listings (below all-CEC median; higher than 3.0% of peers). It delivers 16.06% efficiency, 45.74 V Voc at 25 C, and 51.39 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
205.0 W
PTC Wattage
183.1 W
Voc @ 25C
45.74 V
Efficiency
16.06%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM5(L)(BK)-72-205/SI Compare Against Peer CEC Listings?

How JA Solar JA Solar JAM5(L)(BK)-72-205/SI handles rooftop heat (183.1 W PTC), 8 kW sizing, and cold winter string voltage.

JA Solar builds the JA Solar JAM5(L)(BK)-72-205/SI (Mono-c-Si) as a compact residential or specialty off-grid module delivering 160.5 W/m2 (3.85 percentage points below 19.91% CEC median). Compared against Eoplly New Energy Technology EP125M/72-205W (205.0 W), this model holds typical 89.3% PTC-to-STC thermal output (183.1 W real-world rating). Mid-range 45.74 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 8.88 A overcurrent floor served by a 15 A breaker.

Where Does JA Solar JAM5(L)(BK)-72-205/SI Fall Across Listed CEC Models?

Where JA Solar JAM5(L)(BK)-72-205/SI (205.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM5(L)(BK)-72-205/SI (205.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM5(L)(B: 205.0 W

What Dataset Percentiles Define JA Solar JAM5(L)(BK)-72-205/SI?

Percentile placement of JA Solar JAM5(L)(BK)-72-205/SI across power density (160.5 W/m2), thermal retention, and nameplate STC wattage.

JA Solar JAM5(L)(BK)-72-205/SI Engineering BenchmarksPercentile comparison of JA Solar JAM5(L)(BK)-72-205/SI wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage205.0 WPTC/STC Retention89.3%Module Efficiency16.06%

What Do the Dataset Ranks Show for JA Solar JAM5(L)(BK)-72-205/SI?

Four critical engineering numbers homeowners and solar installers check first when reviewing JA Solar JAM5(L)(BK)-72-205/SI specifications.

Rank #20,980 / 21,677

205.0 W STC · Higher Than 3.0%

205.0 W STC (-180.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,057

16.06% Aperture Efficiency

Power density 160.5 W/m2 (3.85 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.39 V at -10 C (565.3 V string) and 53.01 V at -20 C (11 max).

8 kW Reference Array

40 Panels = 8,200 W STC

Occupies 51.1 m2 (550 sq ft) producing 7,324 W PTC; NEC 690.8 OCPD floor is 8.88 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.74 * (1 + (-0.353/100) * (-10 - 25)) = 51.39 V | OCPD = 1.56 * 5.69 = 8.88 A

Inputs from CEC Modules.csv for JA Solar JAM5(L)(BK)-72-205/SI: Voc=45.74 V, beta_Voc=-0.353%/C, Isc=5.69 A, STC=205.0 W, Area=1.277 m2.

Result: 11 panels max on 600 V (565.3 V); 40 panels for 8 kW (550 sq ft).

What Are the Published CEC Specifications for JA Solar JAM5(L)(BK)-72-205/SI?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for JA Solar JAM5(L)(BK)-72-205/SI.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM5(L)(BK)-72-205/SI.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 205.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 183.1 W (89.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.74 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.69 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.56 V / 5.46 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.353 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.06% (1.277 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many JA Solar JAM5(L)(BK)-72-205/SI Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using JA Solar JAM5(L)(BK)-72-205/SI (205.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 30 6.15 kW 412 sq ft $1,539 $2,603
8 kW Class 40 8.2 kW 550 sq ft $2,052 $3,470
10 kW Class 49 10.04 kW 674 sq ft $2,513 $4,249

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

All closely matched JA Solar wattages and cosmetic trims sharing the JA Solar JAM5(L)(BK)-72-205/SI architecture.

Sibling CEC listings grouped into the JA Solar JAM5(L)(BK)-72-205/SI wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM5(L)(BK)-72-200/SI 200.0 W 178.5 W 45.62 V 37.26 V 15.67%
JA Solar JAM5(L)(BK)-72-205/SI 205.0 W 183.1 W 45.74 V 37.56 V 16.06%
JA Solar JAM5(L)(BK)-72-210/SI 210.0 W 187.8 W 45.9 V 37.86 V 16.45%

How Many JA Solar JAM5(L)(BK)-72-205/SI Modules Fit in a Cold-Weather String?

Maximum series module counts for JA Solar JAM5(L)(BK)-72-205/SI from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.74V and beta_Voc=-0.353%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.01 V 11 panels 583.1 V 18 panels
-10 C (14 F) 51.39 V 11 panels 565.3 V 19 panels
0 C (32 F) 49.78 V 12 panels 597.4 V 20 panels
25 C (77 F STC) 45.74 V 13 panels 594.6 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM5(L)(BK)-72-205/SI?

Alternative CEC solar modules from competing brands near JA Solar JAM5(L)(BK)-72-205/SI (205.0 W), including Eoplly New Energy Technology EP125M/72-205W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Eoplly New Energy Technology EP125M/72-205W
Eoplly New Energy Technology
205.0 W Tie (0 W) 46.21 V 16.06% 89.0%
Anhui Rinengzhongtian Semiconductor Development QJM200-72
Anhui Rinengzhongtian Semiconductor Development
200.0 W -5.0 W 45.7 V 15.67% 89.0%
AXITEC AC-200M/125-72S
AXITEC
200.0 W -5.0 W 45.87 V 15.67% 89.9%
CSI Solar Co Ltd CS6P-210PX
CSI Solar Co Ltd
210.0 W +5.0 W 36.4 V 13.06% 91.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM5(L)(BK)-72-205/SI?

Evaluate JA Solar JAM5(L)(BK)-72-205/SI (205.0 W STC, 45.74 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM5(L)(BK)-72-205/SI reaches 53.01 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 40 panels for an 8 kW build require 550 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (550 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM5(L)(BK)-72-205/SI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM5(L)(BK)-72-205/SI 8 kW Residential Fit

Needs 40 modules (550 sq ft) with a 15 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Eoplly New Energy Technology EP125M/72-205W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 183.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM5(L)(BK)-72-205/SI by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for JA Solar JAM5(L)(BK)-72-205/SI?

Multiplying JA Solar JAM5(L)(BK)-72-205/SI's 5.69 A short-circuit current by 1.56 equals 8.88 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can JA Solar JAM5(L)(BK)-72-205/SI pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.39 V cold Voc at 14 F and handles 5.69 A Isc; string inverters cap JA Solar JAM5(L)(BK)-72-205/SI at 11 panels on 600 V.

Is JA Solar JAM5(L)(BK)-72-205/SI eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM5(L)(BK)-72-205/SI rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.