Skip to main content
WireAndSun
Calculators
CEC PV Module

JA Solar JAM5(L)(BK)-72-190/SI — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM5(L)(BK)-72-190/SI is a 190.0 W STC (169.4 W PTC) Mono-c-Si solar module ranking #21,132 of 21,677 CEC listings (below all-CEC median; higher than 2.3% of peers). It delivers 14.88% efficiency, 45.38 V Voc at 25 C, and 50.99 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
190.0 W
PTC Wattage
169.4 W
Voc @ 25C
45.38 V
Efficiency
14.88%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM5(L)(BK)-72-190/SI Compare Against Peer CEC Listings?

Engineering position of JA Solar JAM5(L)(BK)-72-190/SI (190.0 W STC) vs. AXITEC AC-190M/125-72S across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, JA Solar JAM5(L)(BK)-72-190/SI pairs typical 89.2% PTC-to-STC thermal output (169.4 W real-world rating) with 45.38 V nominal Voc. An 8 kW residential build (8,170 W DC, 7,284 W PTC) saves ~$2,045/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer AXITEC AC-190M/125-72S offers a 190.0 W alternative.

Where Does JA Solar JAM5(L)(BK)-72-190/SI Fall Across Listed CEC Models?

Plots JA Solar JAM5(L)(BK)-72-190/SI at 190.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM5(L)(BK)-72-190/SI (190.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM5(L)(B: 190.0 W

What Dataset Percentiles Define JA Solar JAM5(L)(BK)-72-190/SI?

Benchmarks JA Solar JAM5(L)(BK)-72-190/SI on STC wattage, thermal PTC/STC retention, and 14.88 aperture conversion efficiency against CEC peers.

JA Solar JAM5(L)(BK)-72-190/SI Engineering BenchmarksPercentile comparison of JA Solar JAM5(L)(BK)-72-190/SI wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage190.0 WPTC/STC Retention89.2%Module Efficiency14.88%

What Do the Dataset Ranks Show for JA Solar JAM5(L)(BK)-72-190/SI?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for JA Solar JAM5(L)(BK)-72-190/SI by JA Solar.

Rank #21,132 / 21,677

190.0 W STC · Higher Than 2.3%

190.0 W STC (-195.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #19,900

14.88% Aperture Efficiency

Power density 148.8 W/m2 (5.03 percentage points below 19.91% CEC median). PTC/STC ratio: 89.2% (rank #20,311).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.99 V at -10 C (560.9 V string) and 52.59 V at -20 C (11 max).

8 kW Reference Array

43 Panels = 8,170 W STC

Occupies 54.9 m2 (591 sq ft) producing 7,284 W PTC; NEC 690.8 OCPD floor is 8.7 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.38 * (1 + (-0.353/100) * (-10 - 25)) = 50.99 V | OCPD = 1.56 * 5.58 = 8.7 A

Inputs from CEC Modules.csv for JA Solar JAM5(L)(BK)-72-190/SI: Voc=45.38 V, beta_Voc=-0.353%/C, Isc=5.58 A, STC=190.0 W, Area=1.277 m2.

Result: 11 panels max on 600 V (560.9 V); 43 panels for 8 kW (591 sq ft).

What Are the Published CEC Specifications for JA Solar JAM5(L)(BK)-72-190/SI?

Laboratory test ratings recorded for JA Solar JAM5(L)(BK)-72-190/SI (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM5(L)(BK)-72-190/SI.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 190.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 169.4 W (89.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.38 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.58 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.66 V / 5.18 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.353 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.88% (1.277 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many JA Solar JAM5(L)(BK)-72-190/SI Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (591 sq ft at 8 kW), and estimated Year-1 electric bill offset for JA Solar JAM5(L)(BK)-72-190/SI.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 32 6.08 kW 440 sq ft $1,522 $2,573
8 kW Class 43 8.17 kW 591 sq ft $2,045 $3,458
10 kW Class 53 10.07 kW 729 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Sibling wattage bins and frame colors grouped with JA Solar JAM5(L)(BK)-72-190/SI under JA Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the JA Solar JAM5(L)(BK)-72-190/SI wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM5(L)(BK)-72-180/SI 180.0 W 160.2 W 44.88 V 36.42 V 14.1%
JA Solar JAM5(L)(BK)-72-185/SI 185.0 W 164.8 W 45.18 V 36.54 V 14.49%
JA Solar JAM5(L)(BK)-72-190/SI 190.0 W 169.4 W 45.38 V 36.66 V 14.88%
JA Solar JAM5(L)(BK)-72-195/SI 195.0 W 173.9 W 45.5 V 36.96 V 15.27%

How Many JA Solar JAM5(L)(BK)-72-190/SI Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for JA Solar JAM5(L)(BK)-72-190/SI (beta_Voc -0.353%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=45.38V and beta_Voc=-0.353%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.59 V 11 panels 578.5 V 19 panels
-10 C (14 F) 50.99 V 11 panels 560.9 V 19 panels
0 C (32 F) 49.38 V 12 panels 592.6 V 20 panels
25 C (77 F STC) 45.38 V 13 panels 589.9 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM5(L)(BK)-72-190/SI?

Closest cross-brand CEC competitors to JA Solar JAM5(L)(BK)-72-190/SI matched near 190.0 W STC and 45.38 V Voc, led by AXITEC AC-190M/125-72S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-190M/125-72S
AXITEC
190.0 W Tie (0 W) 45.23 V 14.88% 89.8%
Suntech Power STP190S-24/Ad
Suntech Power
190.0 W Tie (0 W) 45.2 V 14.88% 90.3%
Suntech Power STP190S-24/Adb
Suntech Power
190.0 W Tie (0 W) 45.2 V 14.88% 90.4%
Seraphim Solar System CoLtd SRP-190-5MB
Seraphim Solar System CoLtd
190.0 W Tie (0 W) 45.1 V 14.88% 90.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM5(L)(BK)-72-190/SI?

Evaluate JA Solar JAM5(L)(BK)-72-190/SI (190.0 W STC, 45.38 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM5(L)(BK)-72-190/SI reaches 52.59 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 43 panels for an 8 kW build require 591 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 43 panels (591 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM5(L)(BK)-72-190/SI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM5(L)(BK)-72-190/SI 8 kW Residential Fit

Needs 43 modules (591 sq ft) with a 15 A string OCPD, offsetting ~$2,045/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-190M/125-72S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 169.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM5(L)(BK)-72-190/SI by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for JA Solar JAM5(L)(BK)-72-190/SI?

Multiplying JA Solar JAM5(L)(BK)-72-190/SI's 5.58 A short-circuit current by 1.56 equals 8.7 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can JA Solar JAM5(L)(BK)-72-190/SI pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.99 V cold Voc at 14 F and handles 5.58 A Isc; string inverters cap JA Solar JAM5(L)(BK)-72-190/SI at 11 panels on 600 V.

Is JA Solar JAM5(L)(BK)-72-190/SI eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM5(L)(BK)-72-190/SI rely on utility bill offset (~$2,045/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.