JA Solar JAM5(L)-72-205/SI — CEC Solar Module Specifications

Manufacturer: JA Solar Registry: CEC Verified Engineering Specification

JA Solar JAM5(L)-72-205/SI is a 205.0 W STC (183.1 W PTC) Mono-c-Si solar module ranking #20,980 of 21,677 CEC listings (below all-CEC median; higher than 3.0% of peers). It delivers 16.06% efficiency, 45.74 V Voc at 25 C, and 51.39 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
205.0 W
PTC Wattage
183.1 W
Voc @ 25C
45.74 V
Efficiency
16.06%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does JA Solar JAM5(L)-72-205/SI Compare Against Peer CEC Listings?

Solar engineering breakdown for JA Solar JAM5(L)-72-205/SI: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from JA Solar and peers, JA Solar JAM5(L)-72-205/SI stands 205.0 W below the 410.0 W Mono-c-Si median and typical 89.3% PTC-to-STC thermal output (183.1 W real-world rating). Sizing 6 kW (30 panels) to 10 kW (49 panels) yields $1,539-$2,513/yr in baseline US bill offset. Mid-range 45.74 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does JA Solar JAM5(L)-72-205/SI Fall Across Listed CEC Models?

Distribution marker showing JA Solar JAM5(L)-72-205/SI (205.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where JA Solar JAM5(L)-72-205/SI (205.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCJA Solar JAM5(L)-7: 205.0 W

What Dataset Percentiles Define JA Solar JAM5(L)-72-205/SI?

Dataset percentiles tracking JA Solar JAM5(L)-72-205/SI power output, thermal retention ratio, and aperture efficiency against 21,677 models.

JA Solar JAM5(L)-72-205/SI Engineering BenchmarksPercentile comparison of JA Solar JAM5(L)-72-205/SI wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage205.0 WPTC/STC Retention89.3%Module Efficiency16.06%

What Do the Dataset Ranks Show for JA Solar JAM5(L)-72-205/SI?

Benchmark highlights for JA Solar JAM5(L)-72-205/SI covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #20,980 / 21,677

205.0 W STC · Higher Than 3.0%

205.0 W STC (-180.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,057

16.06% Aperture Efficiency

Power density 160.5 W/m2 (3.85 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.39 V at -10 C (565.3 V string) and 53.01 V at -20 C (11 max).

8 kW Reference Array

40 Panels = 8,200 W STC

Occupies 51.1 m2 (550 sq ft) producing 7,324 W PTC; NEC 690.8 OCPD floor is 8.88 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.74 * (1 + (-0.353/100) * (-10 - 25)) = 51.39 V | OCPD = 1.56 * 5.69 = 8.88 A

Inputs from CEC Modules.csv for JA Solar JAM5(L)-72-205/SI: Voc=45.74 V, beta_Voc=-0.353%/C, Isc=5.69 A, STC=205.0 W, Area=1.277 m2.

Result: 11 panels max on 600 V (565.3 V); 40 panels for 8 kW (550 sq ft).

What Are the Published CEC Specifications for JA Solar JAM5(L)-72-205/SI?

Official CEC datasheet figures for JA Solar JAM5(L)-72-205/SI (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for JA Solar JAM5(L)-72-205/SI.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 205.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 183.1 W (89.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.74 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 5.69 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.56 V / 5.46 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.353 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.06% (1.277 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many JA Solar JAM5(L)-72-205/SI Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many JA Solar JAM5(L)-72-205/SI modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 30 6.15 kW 412 sq ft $1,539 $2,603
8 kW Class 40 8.2 kW 550 sq ft $2,052 $3,470
10 kW Class 49 10.04 kW 674 sq ft $2,513 $4,249

Which Sibling Wattage & Trim Variants Belong to This JA Solar Series?

Consolidated JA Solar wattage variants sharing the JA Solar JAM5(L)-72-205/SI mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the JA Solar JAM5(L)-72-205/SI wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
JA Solar JAM5(L)-72-200/SI 200.0 W 178.5 W 45.62 V 37.26 V 15.67%
JA Solar JAM5(L)-72-205/SI 205.0 W 183.1 W 45.74 V 37.56 V 16.06%
JA Solar JAM5(L)-72-210/SI 210.0 W 187.8 W 45.9 V 37.86 V 16.45%

How Many JA Solar JAM5(L)-72-205/SI Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on JA Solar JAM5(L)-72-205/SI (51.39 V at 14 F).

Computed from Voc=45.74V and beta_Voc=-0.353%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.01 V 11 panels 583.1 V 18 panels
-10 C (14 F) 51.39 V 11 panels 565.3 V 19 panels
0 C (32 F) 49.78 V 12 panels 597.4 V 20 panels
25 C (77 F STC) 45.74 V 13 panels 594.6 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to JA Solar JAM5(L)-72-205/SI?

Competing CEC solar panels closest to JA Solar JAM5(L)-72-205/SI in nameplate wattage and Voc, starting with Eoplly New Energy Technology EP125M/72-205W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Eoplly New Energy Technology EP125M/72-205W
Eoplly New Energy Technology
205.0 W Tie (0 W) 46.21 V 16.06% 89.0%
Anhui Rinengzhongtian Semiconductor Development QJM200-72
Anhui Rinengzhongtian Semiconductor Development
200.0 W -5.0 W 45.7 V 15.67% 89.0%
AXITEC AC-200M/125-72S
AXITEC
200.0 W -5.0 W 45.87 V 15.67% 89.9%
CSI Solar Co Ltd CS6P-210PX
CSI Solar Co Ltd
210.0 W +5.0 W 36.4 V 13.06% 91.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for JA Solar JAM5(L)-72-205/SI?

Evaluate JA Solar JAM5(L)-72-205/SI (205.0 W STC, 45.74 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), JA Solar JAM5(L)-72-205/SI reaches 53.01 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 40 panels for an 8 kW build require 550 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 40 panels (550 sq ft).
  • 2026 tax credit baseline: cash residential installs of JA Solar JAM5(L)-72-205/SI carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

JA Solar JAM5(L)-72-205/SI 8 kW Residential Fit

Needs 40 modules (550 sq ft) with a 15 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Eoplly New Energy Technology EP125M/72-205W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 183.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for JA Solar JAM5(L)-72-205/SI by JA Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for JA Solar JAM5(L)-72-205/SI?

Multiplying JA Solar JAM5(L)-72-205/SI's 5.69 A short-circuit current by 1.56 equals 8.88 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can JA Solar JAM5(L)-72-205/SI pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.39 V cold Voc at 14 F and handles 5.69 A Isc; string inverters cap JA Solar JAM5(L)-72-205/SI at 11 panels on 600 V.

Is JA Solar JAM5(L)-72-205/SI eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of JA Solar JAM5(L)-72-205/SI rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.