Hyperion Solar HY-DH108P8-395-T is a 395.0 W STC (366.9 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.26% efficiency, 36.98 V Voc at 25 C, and 40.95 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 366.9 W
- Voc @ 25C
- 36.98 V
- Efficiency
- 20.26%
How Does Hyperion Solar HY-DH108P8-395-T Compare Against Peer CEC Listings?
Solar engineering breakdown for Hyperion Solar HY-DH108P8-395-T: PTC thermal retention, roof footprint, and cold Voc string bounds. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Measured at 395.0 W STC and 366.9 W PTC, Hyperion Solar HY-DH108P8-395-T sits +10.0 W vs all-CEC median (top 47.6%; higher than 52.4% of peers) among 21,677 listed modules. Power density reaches 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). Lower 36.98 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 24 panels in series. Alternative peer AXITEC AC-395MBT/108V rates 395.0 W.
Where Does Hyperion Solar HY-DH108P8-395-T Fall Across Listed CEC Models?
Distribution marker showing Hyperion Solar HY-DH108P8-395-T (395.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Dataset Percentiles Define Hyperion Solar HY-DH108P8-395-T?
Dataset percentiles tracking Hyperion Solar HY-DH108P8-395-T power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for Hyperion Solar HY-DH108P8-395-T?
Benchmark highlights for Hyperion Solar HY-DH108P8-395-T covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.26% Aperture Efficiency
Power density 202.6 W/m2 (0.35 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.95 V at -10 C (573.3 V string) and 42.09 V at -20 C (14 max).
21 Panels = 8,295 W STC
Occupies 40.9 m2 (441 sq ft) producing 7,705 W PTC; NEC 690.8 OCPD floor is 21.37 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.98 * (1 + (-0.307/100) * (-10 - 25)) = 40.95 V | OCPD = 1.56 * 13.7 = 21.37 A
Inputs from CEC Modules.csv for Hyperion Solar HY-DH108P8-395-T: Voc=36.98 V, beta_Voc=-0.307%/C, Isc=13.7 A, STC=395.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (573.3 V); 21 panels for 8 kW (441 sq ft).
What Are the Published CEC Specifications for Hyperion Solar HY-DH108P8-395-T?
Official CEC datasheet figures for Hyperion Solar HY-DH108P8-395-T (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 366.9 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.98 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.7 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.84 V / 12.81 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.307 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.26% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Hyperion Solar HY-DH108P8-395-T Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hyperion Solar HY-DH108P8-395-T modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 336 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 441 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 546 sq ft | $2,570 | $4,347 |
Which Sibling Wattage & Trim Variants Belong to This Hyperion Solar Series?
Consolidated Hyperion Solar wattage variants sharing the Hyperion Solar HY-DH108P8-395-T mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hyperion Solar HY-DH108P8-390-T | 390.0 W | 362.1 W | 36.85 V | 30.64 V | 20.0% |
| Hyperion Solar HY-DH108P8-395-T | 395.0 W | 366.9 W | 36.98 V | 30.84 V | 20.26% |
How Many Hyperion Solar HY-DH108P8-395-T Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hyperion Solar HY-DH108P8-395-T (40.95 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.09 V | 14 panels | 589.3 V | 23 panels |
| -10 C (14 F) | 40.95 V | 14 panels | 573.3 V | 24 panels |
| 0 C (32 F) | 39.82 V | 15 panels | 597.3 V | 25 panels |
| 25 C (77 F STC) | 36.98 V | 16 panels | 591.7 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to Hyperion Solar HY-DH108P8-395-T?
Competing CEC solar panels closest to Hyperion Solar HY-DH108P8-395-T in nameplate wattage and Voc, starting with AXITEC AC-395MBT/108V.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-395MBT/108V AXITEC |
395.0 W | Tie (0 W) | 37.0 V | 20.47% | 93.3% |
| Elin Energy (Sirius PV) ELNSM54M-HC-BF-395 Elin Energy (Sirius PV) |
395.0 W | Tie (0 W) | 37.02 V | 20.36% | 94.3% |
| Belinus Solar BV BE-M7-GG-108-395 Belinus Solar BV |
395.0 W | Tie (0 W) | 37.03 V | 20.26% | 93.8% |
| ASTORIOS Holding Inc ASTR108BDG-395W-US ASTORIOS Holding Inc |
395.0 W | Tie (0 W) | 36.9 V | 20.36% | 92.9% |
What Are the Design Limits and Best-Fit Uses for Hyperion Solar HY-DH108P8-395-T?
Evaluate Hyperion Solar HY-DH108P8-395-T (395.0 W STC, 36.98 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hyperion Solar HY-DH108P8-395-T reaches 42.09 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 441 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (441 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Hyperion Solar HY-DH108P8-395-T carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hyperion Solar HY-DH108P8-395-T 8 kW Residential Fit
Needs 21 modules (441 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AXITEC AC-395MBT/108V.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 366.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hyperion Solar HY-DH108P8-395-T by Hyperion Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hyperion Solar HY-DH108P8-395-T panels fit on a 600 V winter solar string?
At -10 C (14 F), Hyperion Solar HY-DH108P8-395-T cold Voc rises from 36.98 V to 40.95 V (beta_Voc -0.307%/C), capping a 600 V string at 14 panels (573.3 V).
How much roof area does an 8 kW array of Hyperion Solar HY-DH108P8-395-T need?
An 8 kW DC system uses 21 Hyperion Solar HY-DH108P8-395-T modules (8,295 W STC / 7,705 W PTC), covering roughly 441 sq ft and saving ~$2,075/yr at 18.54 c/kWh.
How does Hyperion Solar HY-DH108P8-395-T compare against AXITEC AC-395MBT/108V?
Hyperion Solar HY-DH108P8-395-T outputs 395.0 W STC (36.98 V Voc, rank #9,869 of 21,677), while AXITEC AC-395MBT/108V delivers 395.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)