Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 is a 275.0 W STC (250.1 W PTC) Multi-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 16.47% efficiency, 38.7 V Voc at 25 C, and 43.08 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 275.0 W
- PTC Wattage
- 250.1 W
- Voc @ 25C
- 38.7 V
- Efficiency
- 16.47%
How Does Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 (Multi-c-Si) residential solar systems.
Homeowners evaluating Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 need 22 panels for 6 kW or 30 panels (539 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (539 sq ft). Under NEC 690.7(A), beta_Voc (-0.323%/C) pushes open-circuit voltage to 43.08 V at 14 F and 44.33 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 Fall Across Listed CEC Models?
Comparison of Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 (275.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275?
Relative ranking of Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 across nameplate watts, 90.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275?
Summary of Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 output rank, 8 kW array size (30 panels), efficiency rating, and 600 V string limit.
275.0 W STC · Higher Than 14.3%
275.0 W STC (-110.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.47% Aperture Efficiency
Power density 164.7 W/m2 (3.44 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.08 V at -10 C (560.0 V string) and 44.33 V at -20 C (13 max).
30 Panels = 8,250 W STC
Occupies 50.1 m2 (539 sq ft) producing 7,503 W PTC; NEC 690.8 OCPD floor is 14.52 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.7 * (1 + (-0.323/100) * (-10 - 25)) = 43.08 V | OCPD = 1.56 * 9.31 = 14.52 A
Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275: Voc=38.7 V, beta_Voc=-0.323%/C, Isc=9.31 A, STC=275.0 W, Area=1.67 m2.
Result: 13 panels max on 600 V (560.0 V); 30 panels for 8 kW (539 sq ft).
What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275?
Complete CEC test sheet for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 including Isc (9.31 A), Voc (38.7 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 275.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 250.1 W (90.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.31 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.3 V / 8.79 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.323 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.47% (1.67 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 22 | 6.05 kW | 395 sq ft | $1,514 | $2,561 |
| 8 kW Class | 30 | 8.25 kW | 539 sq ft | $2,065 | $3,492 |
| 10 kW Class | 37 | 10.18 kW | 665 sq ft | $2,548 | $4,308 |
How Many Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 (38.7 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.33 V | 13 panels | 576.3 V | 22 panels |
| -10 C (14 F) | 43.08 V | 13 panels | 560.0 V | 23 panels |
| 0 C (32 F) | 41.83 V | 14 panels | 585.6 V | 23 panels |
| 25 C (77 F STC) | 38.7 V | 15 panels | 580.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275?
Four comparable CEC modules such as Flextronics FXS-275BB-SAC1B (275.0 W) for side-by-side solar quote checks. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Flextronics FXS-275BB-SAC1B Flextronics |
275.0 W | Tie (0 W) | 38.6 V | 16.75% | 91.4% |
| AXITEC AC-275P/60S AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| AXITEC AC-275P/60V AXITEC |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 92.2% |
| GCL System Integration Technology Co Ltd GCL-M6/60275 GCL System Integration Technology Co Ltd |
275.0 W | Tie (0 W) | 38.5 V | 16.87% | 90.0% |
What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275?
Evaluate Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 (275.0 W STC, 38.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 reaches 44.33 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 30 panels for an 8 kW build require 539 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (539 sq ft).
- 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 8 kW Residential Fit
Needs 30 modules (539 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Flextronics FXS-275BB-SAC1B.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 250.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 PTC wattage (250.1 W) lower than STC (275.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 250.1 W PTC (90.9% retention) across Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275's 1.67 m2 aperture.
Who should skip Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 30 Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 panels (539 sq ft) leave unusable roof gaps vs. Flextronics FXS-275BB-SAC1B.
What is the 1,000 V commercial string limit for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275?
On 1,000 V commercial inverters at -10 C (43.08 V cold Voc), Hanwha Qcells (Qidong) Co Ltd HSL60P6-PC-3-275 fits up to 23 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)