Skip to main content
WireAndSun
Calculators
CEC PV Module

Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW — CEC Solar Module Specifications

Manufacturer: Hanwha Qcells (Qidong) Co Ltd Registry: CEC Verified Engineering Specification

Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW is a 240.0 W STC (213.7 W PTC) Multi-c-Si solar module ranking #20,160 of 21,677 CEC listings (below all-CEC median; higher than 6.1% of peers). It delivers 14.85% efficiency, 37.3 V Voc at 25 C, and 41.46 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
240.0 W
PTC Wattage
213.7 W
Voc @ 25C
37.3 V
Efficiency
14.85%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW (Multi-c-Si) residential solar systems.

Homeowners evaluating Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW need 25 panels for 6 kW or 34 panels (591 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (591 sq ft). Under NEC 690.7(A), beta_Voc (-0.319%/C) pushes open-circuit voltage to 41.46 V at 14 F and 42.65 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW Fall Across Listed CEC Models?

Comparison of Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW (240.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW (240.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanwha Qcells (Qid: 240.0 W

What Dataset Percentiles Define Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW?

Relative ranking of Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW across nameplate watts, 89.0% PTC thermal ratio, and module aperture efficiency.

Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW Engineering BenchmarksPercentile comparison of Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage240.0 WPTC/STC Retention89.0%Module Efficiency14.85%

What Do the Dataset Ranks Show for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW?

Summary of Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW output rank, 8 kW array size (34 panels), efficiency rating, and 600 V string limit.

Rank #20,160 / 21,677

240.0 W STC · Higher Than 6.1%

240.0 W STC (-145.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #19,941

14.85% Aperture Efficiency

Power density 148.5 W/m2 (5.06 percentage points below 19.91% CEC median). PTC/STC ratio: 89.0% (rank #20,637).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.46 V at -10 C (580.4 V string) and 42.65 V at -20 C (14 max).

8 kW Reference Array

34 Panels = 8,160 W STC

Occupies 54.9 m2 (591 sq ft) producing 7,266 W PTC; NEC 690.8 OCPD floor is 13.48 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.3 * (1 + (-0.319/100) * (-10 - 25)) = 41.46 V | OCPD = 1.56 * 8.64 = 13.48 A

Inputs from CEC Modules.csv for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW: Voc=37.3 V, beta_Voc=-0.319%/C, Isc=8.64 A, STC=240.0 W, Area=1.616 m2.

Result: 14 panels max on 600 V (580.4 V); 34 panels for 8 kW (591 sq ft).

What Are the Published CEC Specifications for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW?

Complete CEC test sheet for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW including Isc (8.64 A), Voc (37.3 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 240.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 213.7 W (89.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.64 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 29.4 V / 8.17 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.319 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.85% (1.616 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 25 6.0 kW 435 sq ft $1,502 $2,539
8 kW Class 34 8.16 kW 591 sq ft $2,042 $3,454
10 kW Class 42 10.08 kW 731 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Hanwha Qcells (Qidong) Co Ltd Series?

Related Hanwha Qcells (Qidong) Co Ltd power steps and black/silver trims consolidated into this Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW series guide.

Sibling CEC listings grouped into the Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-235QW 235.0 W 209.1 W 37.0 V 29.2 V 14.54%
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW 240.0 W 213.7 W 37.3 V 29.4 V 14.85%
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-245QW 245.0 W 218.3 W 37.5 V 29.6 V 15.16%

How Many Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW (37.3 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.3V and beta_Voc=-0.319%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.65 V 14 panels 597.1 V 23 panels
-10 C (14 F) 41.46 V 14 panels 580.4 V 24 panels
0 C (32 F) 40.27 V 14 panels 563.8 V 24 panels
25 C (77 F STC) 37.3 V 16 panels 596.8 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW?

Four comparable CEC modules such as CSI Solar Co Ltd CS6P-240M (240.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6P-240M
CSI Solar Co Ltd
240.0 W Tie (0 W) 37.3 V 15.5% 90.5%
CSI Solar Co Ltd CS6P-240MX
CSI Solar Co Ltd
240.0 W Tie (0 W) 37.3 V 15.5% 88.3%
AXITEC AC-240P/156-60B
AXITEC
240.0 W Tie (0 W) 37.4 V 14.79% 89.5%
AXITEC AC-240M/156-60S
AXITEC
240.0 W Tie (0 W) 37.47 V 14.79% 90.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW?

Evaluate Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW (240.0 W STC, 37.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW reaches 42.65 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 34 panels for an 8 kW build require 591 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 34 panels (591 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW 8 kW Residential Fit

Needs 34 modules (591 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare CSI Solar Co Ltd CS6P-240M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 213.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW by Hanwha Qcells (Qidong) Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW PTC wattage (213.7 W) lower than STC (240.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 213.7 W PTC (89.0% retention) across Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW's 1.616 m2 aperture.

Who should skip Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 34 Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW panels (591 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS6P-240M.

What is the 1,000 V commercial string limit for Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW?

On 1,000 V commercial inverters at -10 C (41.46 V cold Voc), Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-4-240QW fits up to 24 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.