Hansol Technics Co Ltd HS430UE-JH2 is a 430.0 W STC (404.7 W PTC) Mono-c-Si solar module ranking #7,266 of 21,677 CEC listings (top 35.2%; higher than 64.8% of peers). It delivers 20.57% efficiency, 53.4 V Voc at 25 C, and 58.6 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 430.0 W
- PTC Wattage
- 404.7 W
- Voc @ 25C
- 53.4 V
- Efficiency
- 20.57%
How Does Hansol Technics Co Ltd HS430UE-JH2 Compare Against Peer CEC Listings?
How Hansol Technics Co Ltd Hansol Technics Co Ltd HS430UE-JH2 handles rooftop heat (404.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Hansol Technics Co Ltd HS430UE-JH2 exhibits 9.97 A short-circuit current, requiring a 15.55 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #7,266 of 21,677 (20.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.7 m2 for an 8 kW system (24 panels for 10 kW). Higher 53.4 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does Hansol Technics Co Ltd HS430UE-JH2 Fall Across Listed CEC Models?
Where Hansol Technics Co Ltd HS430UE-JH2 (430.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS430UE-JH2?
Percentile placement of Hansol Technics Co Ltd HS430UE-JH2 across power density (205.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS430UE-JH2?
Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HS430UE-JH2 specifications.
Top 35.2% STC Output
430.0 W STC (+45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.57% Aperture Efficiency
Power density 205.7 W/m2 (0.66 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 58.6 V at -10 C (586.0 V string) and 60.08 V at -20 C (9 max).
19 Panels = 8,170 W STC
Occupies 39.7 m2 (427 sq ft) producing 7,689 W PTC; NEC 690.8 OCPD floor is 15.55 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 53.4 * (1 + (-0.278/100) * (-10 - 25)) = 58.6 V | OCPD = 1.56 * 9.97 = 15.55 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS430UE-JH2: Voc=53.4 V, beta_Voc=-0.278%/C, Isc=9.97 A, STC=430.0 W, Area=2.09 m2.
Result: 10 panels max on 600 V (586.0 V); 19 panels for 8 kW (427 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS430UE-JH2?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HS430UE-JH2.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 430.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 404.7 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 53.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.97 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 46.3 V / 9.29 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.278 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.57% (2.09 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS430UE-JH2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HS430UE-JH2 (430.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.02 kW | 315 sq ft | $1,507 | $2,548 |
| 8 kW Class | 19 | 8.17 kW | 427 sq ft | $2,045 | $3,458 |
| 10 kW Class | 24 | 10.32 kW | 540 sq ft | $2,583 | $4,368 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
All closely matched Hansol Technics Co Ltd wattages and cosmetic trims sharing the Hansol Technics Co Ltd HS430UE-JH2 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS425UE-JH2 | 425.0 W | 399.9 W | 53.2 V | 46.1 V | 20.33% |
| Hansol Technics Co Ltd HS430UE-JH2 | 430.0 W | 404.7 W | 53.4 V | 46.3 V | 20.57% |
| Hansol Technics Co Ltd HS435UE-JH2 | 435.0 W | 409.5 W | 53.6 V | 46.5 V | 20.81% |
How Many Hansol Technics Co Ltd HS430UE-JH2 Modules Fit in a Cold-Weather String?
Maximum series module counts for Hansol Technics Co Ltd HS430UE-JH2 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 60.08 V | 9 panels | 540.7 V | 16 panels |
| -10 C (14 F) | 58.6 V | 10 panels | 586.0 V | 17 panels |
| 0 C (32 F) | 57.11 V | 10 panels | 571.1 V | 17 panels |
| 25 C (77 F STC) | 53.4 V | 11 panels | 587.4 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS430UE-JH2?
Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HS430UE-JH2 (430.0 W), including Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-144-MF26-435W {Blk} Aptos Solar Technology LLC |
435.0 W | +5.0 W | 49.7 V | 20.71% | 91.8% |
| Aptos Solar Technology LLC DNA-144-MF26-435W {Wht} Aptos Solar Technology LLC |
435.0 W | +5.0 W | 49.7 V | 20.71% | 92.8% |
| CertainTeed CT435HC11-06 CertainTeed |
435.0 W | +5.0 W | 49.7 V | 20.71% | 91.8% |
| AXITEC AC-435MH/144V AXITEC |
435.0 W | +5.0 W | 49.4 V | 20.52% | 92.4% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS430UE-JH2?
Evaluate Hansol Technics Co Ltd HS430UE-JH2 (430.0 W STC, 53.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS430UE-JH2 reaches 60.08 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 427 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (427 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS430UE-JH2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS430UE-JH2 8 kW Residential Fit
Needs 19 modules (427 sq ft) with a 20 A string OCPD, offsetting ~$2,045/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 9 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 404.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS430UE-JH2 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Hansol Technics Co Ltd HS430UE-JH2 PTC wattage (404.7 W) lower than STC (430.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 404.7 W PTC (94.1% retention) across Hansol Technics Co Ltd HS430UE-JH2's 2.09 m2 aperture.
Who should skip Hansol Technics Co Ltd HS430UE-JH2 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 Hansol Technics Co Ltd HS430UE-JH2 panels (427 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.
What is the 1,000 V commercial string limit for Hansol Technics Co Ltd HS430UE-JH2?
On 1,000 V commercial inverters at -10 C (58.6 V cold Voc), Hansol Technics Co Ltd HS430UE-JH2 fits up to 17 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)