Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HS410UE-AN1 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS410UE-AN1 is a 410.0 W STC (378.6 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 19.62% efficiency, 52.1 V Voc at 25 C, and 57.22 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
378.6 W
Voc @ 25C
52.1 V
Efficiency
19.62%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS410UE-AN1 Compare Against Peer CEC Listings?

Solar engineering breakdown for Hansol Technics Co Ltd HS410UE-AN1: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Hansol Technics Co Ltd and peers, Hansol Technics Co Ltd HS410UE-AN1 stands equal to the 410.0 W Mono-c-Si median and strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677). Sizing 6 kW (15 panels) to 10 kW (25 panels) yields $1,539-$2,565/yr in baseline US bill offset. Higher 52.1 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does Hansol Technics Co Ltd HS410UE-AN1 Fall Across Listed CEC Models?

Distribution marker showing Hansol Technics Co Ltd HS410UE-AN1 (410.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS410UE-AN1 (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 410.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS410UE-AN1?

Dataset percentiles tracking Hansol Technics Co Ltd HS410UE-AN1 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Hansol Technics Co Ltd HS410UE-AN1 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS410UE-AN1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention92.3%Module Efficiency19.62%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS410UE-AN1?

Benchmark highlights for Hansol Technics Co Ltd HS410UE-AN1 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,803

19.62% Aperture Efficiency

Power density 196.2 W/m2 (0.29 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.22 V at -10 C (572.2 V string) and 58.69 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 41.8 m2 (450 sq ft) producing 7,572 W PTC; NEC 690.8 OCPD floor is 16.44 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.1 * (1 + (-0.281/100) * (-10 - 25)) = 57.22 V | OCPD = 1.56 * 10.54 = 16.44 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS410UE-AN1: Voc=52.1 V, beta_Voc=-0.281%/C, Isc=10.54 A, STC=410.0 W, Area=2.09 m2.

Result: 10 panels max on 600 V (572.2 V); 20 panels for 8 kW (450 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS410UE-AN1?

Official CEC datasheet figures for Hansol Technics Co Ltd HS410UE-AN1 (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS410UE-AN1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 378.6 W (92.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 52.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.54 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.5 V / 9.64 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.281 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.62% (2.09 m2) Array roof footprint density
Cell Count & Technology 78 cells (Mono-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS410UE-AN1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hansol Technics Co Ltd HS410UE-AN1 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 337 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 450 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 562 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Consolidated Hansol Technics Co Ltd wattage variants sharing the Hansol Technics Co Ltd HS410UE-AN1 mechanical and cell layout.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS410UE-AN1 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS400UE-AN1 400.0 W 369.1 W 51.3 V 41.7 V 19.14%
Hansol Technics Co Ltd HS405UE-AN1 405.0 W 373.8 W 51.7 V 42.1 V 19.38%
Hansol Technics Co Ltd HS410UE-AN1 410.0 W 378.6 W 52.1 V 42.5 V 19.62%
Hansol Technics Co Ltd HS420UE-AN1 420.0 W 388.1 W 52.9 V 43.3 V 20.1%

How Many Hansol Technics Co Ltd HS410UE-AN1 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS410UE-AN1 (57.22 V at 14 F).

Computed from Voc=52.1V and beta_Voc=-0.281%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 58.69 V 10 panels 586.9 V 17 panels
-10 C (14 F) 57.22 V 10 panels 572.2 V 17 panels
0 C (32 F) 55.76 V 10 panels 557.6 V 17 panels
25 C (77 F STC) 52.1 V 11 panels 573.1 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS410UE-AN1?

Competing CEC solar panels closest to Hansol Technics Co Ltd HS410UE-AN1 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS1Y-410MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-410MS
CSI Solar Co Ltd
410.0 W Tie (0 W) 52.7 V 21.03% 94.1%
Auxin Solar AXNG1M410B
Auxin Solar
410.0 W Tie (0 W) 49.47 V 20.92% 93.4%
Auxin Solar AXNG1M410W
Auxin Solar
410.0 W Tie (0 W) 49.47 V 20.92% 93.3%
Dehui Solar Power (Vietnam) CoLtd DH-M872W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W Tie (0 W) 49.4 V 21.47% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS410UE-AN1?

Evaluate Hansol Technics Co Ltd HS410UE-AN1 (410.0 W STC, 52.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS410UE-AN1 reaches 58.69 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 450 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (450 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS410UE-AN1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS410UE-AN1 8 kW Residential Fit

Needs 20 modules (450 sq ft) with a 20 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 378.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS410UE-AN1 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS410UE-AN1?

Multiplying Hansol Technics Co Ltd HS410UE-AN1's 10.54 A short-circuit current by 1.56 equals 16.44 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Hansol Technics Co Ltd HS410UE-AN1 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 57.22 V cold Voc at 14 F and handles 10.54 A Isc; string inverters cap Hansol Technics Co Ltd HS410UE-AN1 at 10 panels on 600 V.

Is Hansol Technics Co Ltd HS410UE-AN1 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS410UE-AN1 rely on utility bill offset (~$2,052/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.