Hansol Technics Co Ltd HS405UD-HH2 is a 405.0 W STC (376.3 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 20.48% efficiency, 49.3 V Voc at 25 C, and 53.92 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 405.0 W
- PTC Wattage
- 376.3 W
- Voc @ 25C
- 49.3 V
- Efficiency
- 20.48%
How Does Hansol Technics Co Ltd HS405UD-HH2 Compare Against Peer CEC Listings?
Engineering position of Hansol Technics Co Ltd HS405UD-HH2 (405.0 W STC) vs. CSI Solar Co Ltd CS3U-405MS across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, Hansol Technics Co Ltd HS405UD-HH2 pairs strong 92.9% PTC-to-STC heat retention (#10,348 of 21,677) with 49.3 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,526 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS3U-405MS offers a 405.0 W alternative.
Where Does Hansol Technics Co Ltd HS405UD-HH2 Fall Across Listed CEC Models?
Plots Hansol Technics Co Ltd HS405UD-HH2 at 405.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS405UD-HH2?
Benchmarks Hansol Technics Co Ltd HS405UD-HH2 on STC wattage, thermal PTC/STC retention, and 20.48 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS405UD-HH2?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hansol Technics Co Ltd HS405UD-HH2 by Hansol Technics Co Ltd.
Top 43.4% STC Output
405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.48% Aperture Efficiency
Power density 204.8 W/m2 (0.57 percentage points above 19.91% CEC median). PTC/STC ratio: 92.9% (rank #10,348).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.92 V at -10 C (593.1 V string) and 55.25 V at -20 C (10 max).
20 Panels = 8,100 W STC
Occupies 39.6 m2 (426 sq ft) producing 7,526 W PTC; NEC 690.8 OCPD floor is 15.97 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.3 * (1 + (-0.268/100) * (-10 - 25)) = 53.92 V | OCPD = 1.56 * 10.24 = 15.97 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS405UD-HH2: Voc=49.3 V, beta_Voc=-0.268%/C, Isc=10.24 A, STC=405.0 W, Area=1.978 m2.
Result: 11 panels max on 600 V (593.1 V); 20 panels for 8 kW (426 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS405UD-HH2?
Laboratory test ratings recorded for Hansol Technics Co Ltd HS405UD-HH2 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 405.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 376.3 W (92.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.24 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.7 V / 9.72 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.48% (1.978 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS405UD-HH2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (426 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hansol Technics Co Ltd HS405UD-HH2.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.08 kW | 319 sq ft | $1,522 | $2,573 |
| 8 kW Class | 20 | 8.1 kW | 426 sq ft | $2,027 | $3,428 |
| 10 kW Class | 25 | 10.12 kW | 532 sq ft | $2,533 | $4,283 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Sibling wattage bins and frame colors grouped with Hansol Technics Co Ltd HS405UD-HH2 under Hansol Technics Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS400UD-HH2 | 400.0 W | 371.5 W | 49.1 V | 41.5 V | 20.22% |
| Hansol Technics Co Ltd HS405UD-HH2 | 405.0 W | 376.3 W | 49.3 V | 41.7 V | 20.48% |
How Many Hansol Technics Co Ltd HS405UD-HH2 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Hansol Technics Co Ltd HS405UD-HH2 (beta_Voc -0.268%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.25 V | 10 panels | 552.5 V | 18 panels |
| -10 C (14 F) | 53.92 V | 11 panels | 593.1 V | 18 panels |
| 0 C (32 F) | 52.6 V | 11 panels | 578.6 V | 19 panels |
| 25 C (77 F STC) | 49.3 V | 12 panels | 591.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS405UD-HH2?
Closest cross-brand CEC competitors to Hansol Technics Co Ltd HS405UD-HH2 matched near 405.0 W STC and 49.3 V Voc, led by CSI Solar Co Ltd CS3U-405MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3U-405MS CSI Solar Co Ltd |
405.0 W | Tie (0 W) | 49.3 V | 21.09% | 93.0% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-HC-405W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
405.0 W | Tie (0 W) | 49.2 V | 21.2% | 92.6% |
| Boviet Solar Technology Co Ltd BVM6612M-405L-H Boviet Solar Technology Co Ltd |
405.0 W | Tie (0 W) | 49.45 V | 20.35% | 93.3% |
| Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC Boviet Solar Technology Co Ltd |
405.0 W | Tie (0 W) | 49.45 V | 19.95% | 93.6% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS405UD-HH2?
Evaluate Hansol Technics Co Ltd HS405UD-HH2 (405.0 W STC, 49.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS405UD-HH2 reaches 55.25 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 426 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (426 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS405UD-HH2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS405UD-HH2 8 kW Residential Fit
Needs 20 modules (426 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3U-405MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 376.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS405UD-HH2 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS405UD-HH2?
Multiplying Hansol Technics Co Ltd HS405UD-HH2's 10.24 A short-circuit current by 1.56 equals 15.97 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HS405UD-HH2 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.92 V cold Voc at 14 F and handles 10.24 A Isc; string inverters cap Hansol Technics Co Ltd HS405UD-HH2 at 11 panels on 600 V.
Is Hansol Technics Co Ltd HS405UD-HH2 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS405UD-HH2 rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)