Hansol Technics Co Ltd HS370UD-JH2 is a 370.0 W STC (346.5 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 19.18% efficiency, 47.5 V Voc at 25 C, and 52.12 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 370.0 W
- PTC Wattage
- 346.5 W
- Voc @ 25C
- 47.5 V
- Efficiency
- 19.18%
How Does Hansol Technics Co Ltd HS370UD-JH2 Compare Against Peer CEC Listings?
Solar engineering breakdown for Hansol Technics Co Ltd HS370UD-JH2: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Hansol Technics Co Ltd and peers, Hansol Technics Co Ltd HS370UD-JH2 stands 40.0 W below the 410.0 W Mono-c-Si median and strong 93.6% PTC-to-STC heat retention (#6,726 of 21,677). Sizing 6 kW (17 panels) to 10 kW (28 panels) yields $1,574-$2,593/yr in baseline US bill offset. Mid-range 47.5 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Hansol Technics Co Ltd HS370UD-JH2 Fall Across Listed CEC Models?
Distribution marker showing Hansol Technics Co Ltd HS370UD-JH2 (370.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS370UD-JH2?
Dataset percentiles tracking Hansol Technics Co Ltd HS370UD-JH2 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS370UD-JH2?
Benchmark highlights for Hansol Technics Co Ltd HS370UD-JH2 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
370.0 W STC · Higher Than 44.4%
370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.18% Aperture Efficiency
Power density 191.8 W/m2 (0.73 percentage points below 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.12 V at -10 C (573.3 V string) and 53.44 V at -20 C (11 max).
22 Panels = 8,140 W STC
Occupies 42.4 m2 (457 sq ft) producing 7,623 W PTC; NEC 690.8 OCPD floor is 15.33 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.5 * (1 + (-0.278/100) * (-10 - 25)) = 52.12 V | OCPD = 1.56 * 9.83 = 15.33 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS370UD-JH2: Voc=47.5 V, beta_Voc=-0.278%/C, Isc=9.83 A, STC=370.0 W, Area=1.929 m2.
Result: 11 panels max on 600 V (573.3 V); 22 panels for 8 kW (457 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS370UD-JH2?
Official CEC datasheet figures for Hansol Technics Co Ltd HS370UD-JH2 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 370.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 346.5 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.9 V / 9.28 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.278 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.18% (1.929 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS370UD-JH2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hansol Technics Co Ltd HS370UD-JH2 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.29 kW | 353 sq ft | $1,574 | $2,662 |
| 8 kW Class | 22 | 8.14 kW | 457 sq ft | $2,037 | $3,445 |
| 10 kW Class | 28 | 10.36 kW | 581 sq ft | $2,593 | $4,385 |
How Many Hansol Technics Co Ltd HS370UD-JH2 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS370UD-JH2 (52.12 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.44 V | 11 panels | 587.8 V | 18 panels |
| -10 C (14 F) | 52.12 V | 11 panels | 573.3 V | 19 panels |
| 0 C (32 F) | 50.8 V | 11 panels | 558.8 V | 19 panels |
| 25 C (77 F STC) | 47.5 V | 12 panels | 570.0 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS370UD-JH2?
Competing CEC solar panels closest to Hansol Technics Co Ltd HS370UD-JH2 in nameplate wattage and Voc, starting with CertainTeed CT370M00-04.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CT370M00-04 CertainTeed |
370.0 W | Tie (0 W) | 47.9 V | 19.66% | 93.2% |
| Bluesun Solar Energy Tech CoLtd BSM370M-72 Bluesun Solar Energy Tech CoLtd |
370.0 W | Tie (0 W) | 48.23 V | 19.07% | 91.9% |
| Caterpillar Inc PVC370MP03H Caterpillar Inc |
370.0 W | Tie (0 W) | 48.6 V | 19.11% | 94.1% |
| Boviet Solar Technology Co Ltd BVM6612M-365-H Boviet Solar Technology Co Ltd |
365.0 W | -5.0 W | 47.6 V | 18.81% | 93.0% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS370UD-JH2?
Evaluate Hansol Technics Co Ltd HS370UD-JH2 (370.0 W STC, 47.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS370UD-JH2 reaches 53.44 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 457 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (457 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS370UD-JH2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS370UD-JH2 8 kW Residential Fit
Needs 22 modules (457 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CertainTeed CT370M00-04.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 346.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS370UD-JH2 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS370UD-JH2?
Multiplying Hansol Technics Co Ltd HS370UD-JH2's 9.83 A short-circuit current by 1.56 equals 15.33 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HS370UD-JH2 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 52.12 V cold Voc at 14 F and handles 9.83 A Isc; string inverters cap Hansol Technics Co Ltd HS370UD-JH2 at 11 panels on 600 V.
Is Hansol Technics Co Ltd HS370UD-JH2 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS370UD-JH2 rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)