Hansol Technics Co Ltd HS360UD-AN1 {Wht} is a 360.0 W STC (333.8 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.75% efficiency, 47.4 V Voc at 25 C, and 52.09 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 333.8 W
- Voc @ 25C
- 47.4 V
- Efficiency
- 18.75%
How Does Hansol Technics Co Ltd HS360UD-AN1 {Wht} Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HS360UD-AN1 {Wht} (Mono-c-Si) residential solar systems.
Homeowners evaluating Hansol Technics Co Ltd HS360UD-AN1 {Wht} need 17 panels for 6 kW or 23 panels (475 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (475 sq ft). Under NEC 690.7(A), beta_Voc (-0.283%/C) pushes open-circuit voltage to 52.09 V at 14 F and 53.44 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Hansol Technics Co Ltd HS360UD-AN1 {Wht} Fall Across Listed CEC Models?
Comparison of Hansol Technics Co Ltd HS360UD-AN1 {Wht} (360.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Hansol Technics Co Ltd HS360UD-AN1 {Wht}?
Relative ranking of Hansol Technics Co Ltd HS360UD-AN1 {Wht} across nameplate watts, 92.7% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS360UD-AN1 {Wht}?
Summary of Hansol Technics Co Ltd HS360UD-AN1 {Wht} output rank, 8 kW array size (23 panels), efficiency rating, and 600 V string limit.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.75% Aperture Efficiency
Power density 187.5 W/m2 (1.16 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.09 V at -10 C (573.0 V string) and 53.44 V at -20 C (11 max).
23 Panels = 8,280 W STC
Occupies 44.2 m2 (475 sq ft) producing 7,677 W PTC; NEC 690.8 OCPD floor is 15.09 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.4 * (1 + (-0.283/100) * (-10 - 25)) = 52.09 V | OCPD = 1.56 * 9.67 = 15.09 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS360UD-AN1 {Wht}: Voc=47.4 V, beta_Voc=-0.283%/C, Isc=9.67 A, STC=360.0 W, Area=1.92 m2.
Result: 11 panels max on 600 V (573.0 V); 23 panels for 8 kW (475 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS360UD-AN1 {Wht}?
Complete CEC test sheet for Hansol Technics Co Ltd HS360UD-AN1 {Wht} including Isc (9.67 A), Voc (47.4 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 333.8 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.67 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.7 V / 9.07 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.283 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.75% (1.92 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS360UD-AN1 {Wht} Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HS360UD-AN1 {Wht}.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 351 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 475 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 579 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Related Hansol Technics Co Ltd power steps and black/silver trims consolidated into this Hansol Technics Co Ltd HS360UD-AN1 {Wht} series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS350UD-AN1 {Wht} | 350.0 W | 320.0 W | 46.7 V | 38.9 V | 18.04% |
| Hansol Technics Co Ltd HS355UD-AN1 {Wht} | 355.0 W | 329.0 W | 47.0 V | 39.3 V | 18.49% |
| Hansol Technics Co Ltd HS360UD-AN1 {Wht} | 360.0 W | 333.8 W | 47.4 V | 39.7 V | 18.75% |
| Hansol Technics Co Ltd HS365UD-AN1 {Wht} | 365.0 W | 338.5 W | 47.8 V | 40.1 V | 19.01% |
| Hansol Technics Co Ltd HS370UD-AN1 {Wht} | 370.0 W | 343.3 W | 48.2 V | 40.5 V | 19.27% |
How Many Hansol Technics Co Ltd HS360UD-AN1 {Wht} Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Hansol Technics Co Ltd HS360UD-AN1 {Wht} (47.4 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.44 V | 11 panels | 587.8 V | 18 panels |
| -10 C (14 F) | 52.09 V | 11 panels | 573.0 V | 19 panels |
| 0 C (32 F) | 50.75 V | 11 panels | 558.2 V | 19 panels |
| 25 C (77 F STC) | 47.4 V | 12 panels | 568.8 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS360UD-AN1 {Wht}?
Four comparable CEC modules such as CertainTeed CT360M11-03 (360.0 W) for side-by-side solar quote checks. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CT360M11-03 CertainTeed |
360.0 W | Tie (0 W) | 47.4 V | 18.72% | 92.3% |
| AXITEC AC-360M/72S AXITEC |
360.0 W | Tie (0 W) | 47.44 V | 18.55% | 91.2% |
| AXITEC AC-360M/72V AXITEC |
360.0 W | Tie (0 W) | 47.44 V | 18.55% | 91.2% |
| Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72 Anhui Rinengzhongtian Semiconductor Development Co Ltd |
360.0 W | Tie (0 W) | 47.46 V | 18.55% | 91.1% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS360UD-AN1 {Wht}?
Evaluate Hansol Technics Co Ltd HS360UD-AN1 {Wht} (360.0 W STC, 47.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS360UD-AN1 {Wht} reaches 53.44 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 475 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (475 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS360UD-AN1 {Wht} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS360UD-AN1 {Wht} 8 kW Residential Fit
Needs 23 modules (475 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CertainTeed CT360M11-03.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 333.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS360UD-AN1 {Wht} by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Hansol Technics Co Ltd HS360UD-AN1 {Wht} PTC wattage (333.8 W) lower than STC (360.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 333.8 W PTC (92.7% retention) across Hansol Technics Co Ltd HS360UD-AN1 {Wht}'s 1.92 m2 aperture.
Who should skip Hansol Technics Co Ltd HS360UD-AN1 {Wht} on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 23 Hansol Technics Co Ltd HS360UD-AN1 {Wht} panels (475 sq ft) leave unusable roof gaps vs. CertainTeed CT360M11-03.
What is the 1,000 V commercial string limit for Hansol Technics Co Ltd HS360UD-AN1 {Wht}?
On 1,000 V commercial inverters at -10 C (52.09 V cold Voc), Hansol Technics Co Ltd HS360UD-AN1 {Wht} fits up to 19 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)