Skip to main content
WireAndSun
Calculators
CEC PV Module

AXITEC AC-360M/72S — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-360M/72S is a 360.0 W STC (328.3 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.55% efficiency, 47.44 V Voc at 25 C, and 52.47 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
328.3 W
Voc @ 25C
47.44 V
Efficiency
18.55%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-360M/72S Compare Against Peer CEC Listings?

Solar engineering breakdown for AXITEC AC-360M/72S: PTC thermal retention, roof footprint, and cold Voc string bounds. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Measured at 360.0 W STC and 328.3 W PTC, AXITEC AC-360M/72S sits -25.0 W vs all-CEC median (below all-CEC median; higher than 41.3% of peers) among 21,677 listed modules. Power density reaches 185.6 W/m2 (1.36 percentage points below 19.91% CEC median). Mid-range 47.44 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72 rates 360.0 W.

Where Does AXITEC AC-360M/72S Fall Across Listed CEC Models?

Distribution marker showing AXITEC AC-360M/72S (360.0 W) relative to the 385.0 W all-CEC solar panel median. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-360M/72S (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-360M/72S: 360.0 W

What Dataset Percentiles Define AXITEC AC-360M/72S?

Dataset percentiles tracking AXITEC AC-360M/72S power output, thermal retention ratio, and aperture efficiency against 21,677 models. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

AXITEC AC-360M/72S Engineering BenchmarksPercentile comparison of AXITEC AC-360M/72S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention91.2%Module Efficiency18.55%

What Do the Dataset Ranks Show for AXITEC AC-360M/72S?

Benchmark highlights for AXITEC AC-360M/72S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,270

18.55% Aperture Efficiency

Power density 185.6 W/m2 (1.36 percentage points below 19.91% CEC median). PTC/STC ratio: 91.2% (rank #16,270).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.47 V at -10 C (577.2 V string) and 53.91 V at -20 C (11 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 44.6 m2 (480 sq ft) producing 7,551 W PTC; NEC 690.8 OCPD floor is 15.18 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.44 * (1 + (-0.303/100) * (-10 - 25)) = 52.47 V | OCPD = 1.56 * 9.73 = 15.18 A

Inputs from CEC Modules.csv for AXITEC AC-360M/72S: Voc=47.44 V, beta_Voc=-0.303%/C, Isc=9.73 A, STC=360.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (577.2 V); 23 panels for 8 kW (480 sq ft).

What Are the Published CEC Specifications for AXITEC AC-360M/72S?

Official CEC datasheet figures for AXITEC AC-360M/72S (Mono-c-Si) used in utility interconnection and permit reviews. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-360M/72S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 328.3 W (91.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.44 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.73 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.01 V / 9.23 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.303 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.55% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many AXITEC AC-360M/72S Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many AXITEC AC-360M/72S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 355 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 480 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 585 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Consolidated AXITEC wattage variants sharing the AXITEC AC-360M/72S mechanical and cell layout. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the AXITEC AC-360M/72S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-350M/72S 350.0 W 319.0 W 46.89 V 38.34 V 18.13%
AXITEC AC-355M/72S 355.0 W 323.7 W 47.16 V 38.63 V 18.39%
AXITEC AC-360M/72S 360.0 W 328.3 W 47.44 V 39.01 V 18.55%
AXITEC AC-365M/72S 365.0 W 333.1 W 47.67 V 39.38 V 18.91%
AXITEC AC-370M/72S 370.0 W 337.7 W 47.91 V 39.84 V 19.07%

How Many AXITEC AC-360M/72S Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on AXITEC AC-360M/72S (52.47 V at 14 F).

Computed from Voc=47.44V and beta_Voc=-0.303%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.91 V 11 panels 593.0 V 18 panels
-10 C (14 F) 52.47 V 11 panels 577.2 V 19 panels
0 C (32 F) 51.03 V 11 panels 561.3 V 19 panels
25 C (77 F STC) 47.44 V 12 panels 569.3 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-360M/72S?

Competing CEC solar panels closest to AXITEC AC-360M/72S in nameplate wattage and Voc, starting with Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72
Anhui Rinengzhongtian Semiconductor Development Co Ltd
360.0 W Tie (0 W) 47.46 V 18.55% 91.1%
CertainTeed CT360M11-03
CertainTeed
360.0 W Tie (0 W) 47.4 V 18.72% 92.3%
Boviet Solar Technology Co Ltd BVM6612M-360
Boviet Solar Technology Co Ltd
360.0 W Tie (0 W) 47.5 V 18.56% 92.3%
Advance Power API-M360
Advance Power
360.0 W Tie (0 W) 47.56 V 18.56% 91.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-360M/72S?

Evaluate AXITEC AC-360M/72S (360.0 W STC, 47.44 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-360M/72S reaches 53.91 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 480 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (480 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-360M/72S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-360M/72S 8 kW Residential Fit

Needs 23 modules (480 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 328.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-360M/72S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

How many AXITEC AC-360M/72S panels fit on a 600 V winter solar string?

At -10 C (14 F), AXITEC AC-360M/72S cold Voc rises from 47.44 V to 52.47 V (beta_Voc -0.303%/C), capping a 600 V string at 11 panels (577.2 V).

How much roof area does an 8 kW array of AXITEC AC-360M/72S need?

An 8 kW DC system uses 23 AXITEC AC-360M/72S modules (8,280 W STC / 7,551 W PTC), covering roughly 480 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

How does AXITEC AC-360M/72S compare against Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72?

AXITEC AC-360M/72S outputs 360.0 W STC (47.44 V Voc, rank #12,385 of 21,677), while Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72 delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.