Hansol Technics Co Ltd HS360UD-AN1 {Blk} is a 360.0 W STC (332.3 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 18.75% efficiency, 47.4 V Voc at 25 C, and 52.06 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 332.3 W
- Voc @ 25C
- 47.4 V
- Efficiency
- 18.75%
How Does Hansol Technics Co Ltd HS360UD-AN1 {Blk} Compare Against Peer CEC Listings?
Engineering position of Hansol Technics Co Ltd HS360UD-AN1 {Blk} (360.0 W STC) vs. CertainTeed CT360M11-03 across 5,889 CEC Mono-c-Si solar modules.
Ranking #12,385 across 21,677 CEC solar panels (below all-CEC median; higher than 41.3% of peers), Hansol Technics Co Ltd HS360UD-AN1 {Blk} operates as a compact residential or specialty off-grid module sitting 50.0 W below the 410.0 W Mono-c-Si median. Mid-range 47.4 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677), 23 panels occupy 475 sq ft and offset roughly $2,072/yr at average US rates (or $3,504/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Hansol Technics Co Ltd HS360UD-AN1 {Blk} Fall Across Listed CEC Models?
Plots Hansol Technics Co Ltd HS360UD-AN1 {Blk} at 360.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS360UD-AN1 {Blk}?
Benchmarks Hansol Technics Co Ltd HS360UD-AN1 {Blk} on STC wattage, thermal PTC/STC retention, and 18.75 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS360UD-AN1 {Blk}?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hansol Technics Co Ltd HS360UD-AN1 {Blk} by Hansol Technics Co Ltd.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.75% Aperture Efficiency
Power density 187.5 W/m2 (1.16 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.06 V at -10 C (572.7 V string) and 53.39 V at -20 C (11 max).
23 Panels = 8,280 W STC
Occupies 44.2 m2 (475 sq ft) producing 7,643 W PTC; NEC 690.8 OCPD floor is 15.09 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.4 * (1 + (-0.281/100) * (-10 - 25)) = 52.06 V | OCPD = 1.56 * 9.67 = 15.09 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS360UD-AN1 {Blk}: Voc=47.4 V, beta_Voc=-0.281%/C, Isc=9.67 A, STC=360.0 W, Area=1.92 m2.
Result: 11 panels max on 600 V (572.7 V); 23 panels for 8 kW (475 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS360UD-AN1 {Blk}?
Laboratory test ratings recorded for Hansol Technics Co Ltd HS360UD-AN1 {Blk} (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 332.3 W (92.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.67 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.7 V / 9.07 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.281 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.75% (1.92 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS360UD-AN1 {Blk} Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (475 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hansol Technics Co Ltd HS360UD-AN1 {Blk}.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 351 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 475 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 579 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Sibling wattage bins and frame colors grouped with Hansol Technics Co Ltd HS360UD-AN1 {Blk} under Hansol Technics Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS350UD-AN1 {Blk} | 350.0 W | 322.8 W | 46.7 V | 38.9 V | 18.23% |
| Hansol Technics Co Ltd HS355UD-AN1 {Blk} | 355.0 W | 327.6 W | 47.0 V | 39.3 V | 18.49% |
| Hansol Technics Co Ltd HS360UD-AN1 {Blk} | 360.0 W | 332.3 W | 47.4 V | 39.7 V | 18.75% |
| Hansol Technics Co Ltd HS365UD-AN1 {Blk} | 365.0 W | 337.0 W | 47.8 V | 40.1 V | 19.01% |
| Hansol Technics Co Ltd HS370UD-AN1 {Blk} | 370.0 W | 341.8 W | 48.2 V | 40.5 V | 19.27% |
How Many Hansol Technics Co Ltd HS360UD-AN1 {Blk} Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Hansol Technics Co Ltd HS360UD-AN1 {Blk} (beta_Voc -0.281%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.39 V | 11 panels | 587.3 V | 18 panels |
| -10 C (14 F) | 52.06 V | 11 panels | 572.7 V | 19 panels |
| 0 C (32 F) | 50.73 V | 11 panels | 558.0 V | 19 panels |
| 25 C (77 F STC) | 47.4 V | 12 panels | 568.8 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS360UD-AN1 {Blk}?
Closest cross-brand CEC competitors to Hansol Technics Co Ltd HS360UD-AN1 {Blk} matched near 360.0 W STC and 47.4 V Voc, led by CertainTeed CT360M11-03.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CT360M11-03 CertainTeed |
360.0 W | Tie (0 W) | 47.4 V | 18.72% | 92.3% |
| AXITEC AC-360M/72S AXITEC |
360.0 W | Tie (0 W) | 47.44 V | 18.55% | 91.2% |
| AXITEC AC-360M/72V AXITEC |
360.0 W | Tie (0 W) | 47.44 V | 18.55% | 91.2% |
| Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM360-72 Anhui Rinengzhongtian Semiconductor Development Co Ltd |
360.0 W | Tie (0 W) | 47.46 V | 18.55% | 91.1% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS360UD-AN1 {Blk}?
Evaluate Hansol Technics Co Ltd HS360UD-AN1 {Blk} (360.0 W STC, 47.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS360UD-AN1 {Blk} reaches 53.39 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 475 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (475 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS360UD-AN1 {Blk} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS360UD-AN1 {Blk} 8 kW Residential Fit
Needs 23 modules (475 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CertainTeed CT360M11-03.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 332.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS360UD-AN1 {Blk} by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hansol Technics Co Ltd HS360UD-AN1 {Blk} panels fit on a 600 V winter solar string?
At -10 C (14 F), Hansol Technics Co Ltd HS360UD-AN1 {Blk} cold Voc rises from 47.4 V to 52.06 V (beta_Voc -0.281%/C), capping a 600 V string at 11 panels (572.7 V).
How much roof area does an 8 kW array of Hansol Technics Co Ltd HS360UD-AN1 {Blk} need?
An 8 kW DC system uses 23 Hansol Technics Co Ltd HS360UD-AN1 {Blk} modules (8,280 W STC / 7,643 W PTC), covering roughly 475 sq ft and saving ~$2,072/yr at 18.54 c/kWh.
How does Hansol Technics Co Ltd HS360UD-AN1 {Blk} compare against CertainTeed CT360M11-03?
Hansol Technics Co Ltd HS360UD-AN1 {Blk} outputs 360.0 W STC (47.4 V Voc, rank #12,385 of 21,677), while CertainTeed CT360M11-03 delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)