Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS335TD-AN3 is a 335.0 W STC (303.3 W PTC) Multi-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 16.8% efficiency, 46.2 V Voc at 25 C, and 51.21 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
335.0 W
PTC Wattage
303.3 W
Voc @ 25C
46.2 V
Efficiency
16.8%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS335TD-AN3 Compare Against Peer CEC Listings?

How Hansol Technics Co Ltd Hansol Technics Co Ltd HS335TD-AN3 handles rooftop heat (303.3 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Hansol Technics Co Ltd HS335TD-AN3 exhibits 9.5 A short-circuit current, requiring a 14.82 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #13,844 of 21,677 (56.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 47.9 m2 for an 8 kW system (30 panels for 10 kW). Mid-range 46.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Hansol Technics Co Ltd HS335TD-AN3 Fall Across Listed CEC Models?

Where Hansol Technics Co Ltd HS335TD-AN3 (335.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS335TD-AN3 (335.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 335.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS335TD-AN3?

Percentile placement of Hansol Technics Co Ltd HS335TD-AN3 across power density (168.0 W/m2), thermal retention, and nameplate STC wattage.

Hansol Technics Co Ltd HS335TD-AN3 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS335TD-AN3 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage335.0 WPTC/STC Retention90.5%Module Efficiency16.8%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS335TD-AN3?

Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HS335TD-AN3 specifications.

Rank #13,844 / 21,677

335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,762

16.8% Aperture Efficiency

Power density 168.0 W/m2 (3.11 percentage points below 19.91% CEC median). PTC/STC ratio: 90.5% (rank #17,786).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.21 V at -10 C (563.3 V string) and 52.64 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,040 W STC

Occupies 47.9 m2 (515 sq ft) producing 7,279 W PTC; NEC 690.8 OCPD floor is 14.82 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.2 * (1 + (-0.31/100) * (-10 - 25)) = 51.21 V | OCPD = 1.56 * 9.5 = 14.82 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS335TD-AN3: Voc=46.2 V, beta_Voc=-0.31%/C, Isc=9.5 A, STC=335.0 W, Area=1.994 m2.

Result: 11 panels max on 600 V (563.3 V); 24 panels for 8 kW (515 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS335TD-AN3?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HS335TD-AN3.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS335TD-AN3.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 335.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 303.3 W (90.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.5 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.6 V / 8.92 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.31 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.8% (1.994 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS335TD-AN3 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HS335TD-AN3 (335.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.03 kW 386 sq ft $1,509 $2,552
8 kW Class 24 8.04 kW 515 sq ft $2,012 $3,403
10 kW Class 30 10.05 kW 644 sq ft $2,515 $4,253

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

All closely matched Hansol Technics Co Ltd wattages and cosmetic trims sharing the Hansol Technics Co Ltd HS335TD-AN3 architecture.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS335TD-AN3 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS325TD-AN3 325.0 W 293.9 W 46.5 V 37.5 V 16.3%
Hansol Technics Co Ltd HS330TD-AN3 330.0 W 298.6 W 46.9 V 37.9 V 16.55%
Hansol Technics Co Ltd HS335TD-AN3 335.0 W 303.3 W 46.2 V 37.6 V 16.8%
Hansol Technics Co Ltd HS340TD-AN3 340.0 W 307.9 W 46.6 V 38.0 V 17.05%
Hansol Technics Co Ltd HS345TD-AN3 345.0 W 312.6 W 47.0 V 38.4 V 17.3%

How Many Hansol Technics Co Ltd HS335TD-AN3 Modules Fit in a Cold-Weather String?

Maximum series module counts for Hansol Technics Co Ltd HS335TD-AN3 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.2V and beta_Voc=-0.31%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.64 V 11 panels 579.0 V 18 panels
-10 C (14 F) 51.21 V 11 panels 563.3 V 19 panels
0 C (32 F) 49.78 V 12 panels 597.4 V 20 panels
25 C (77 F STC) 46.2 V 12 panels 554.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS335TD-AN3?

Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HS335TD-AN3 (335.0 W), including AXITEC AC-335P/156-72S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-335P/156-72S
AXITEC
335.0 W Tie (0 W) 46.2 V 17.26% 91.0%
Flextronics FXS-335BB-SAD1W
Flextronics
335.0 W Tie (0 W) 46.2 V 17.13% 91.2%
Boviet Solar Technology Co Ltd BVM6612P-335
Boviet Solar Technology Co Ltd
335.0 W Tie (0 W) 46.1 V 17.27% 92.5%
Boviet Solar Technology Co Ltd BVM6612M-335
Boviet Solar Technology Co Ltd
335.0 W Tie (0 W) 46.4 V 17.27% 91.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS335TD-AN3?

Evaluate Hansol Technics Co Ltd HS335TD-AN3 (335.0 W STC, 46.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS335TD-AN3 reaches 52.64 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 515 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (515 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS335TD-AN3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS335TD-AN3 8 kW Residential Fit

Needs 24 modules (515 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-335P/156-72S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 303.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS335TD-AN3 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Hansol Technics Co Ltd HS335TD-AN3 PTC wattage (303.3 W) lower than STC (335.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 303.3 W PTC (90.5% retention) across Hansol Technics Co Ltd HS335TD-AN3's 1.994 m2 aperture.

Who should skip Hansol Technics Co Ltd HS335TD-AN3 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 Hansol Technics Co Ltd HS335TD-AN3 panels (515 sq ft) leave unusable roof gaps vs. AXITEC AC-335P/156-72S.

What is the 1,000 V commercial string limit for Hansol Technics Co Ltd HS335TD-AN3?

On 1,000 V commercial inverters at -10 C (51.21 V cold Voc), Hansol Technics Co Ltd HS335TD-AN3 fits up to 19 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.