Skip to main content
WireAndSun
Calculators
CEC PV Module

AXITEC AC-335P/156-72S — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-335P/156-72S is a 335.0 W STC (304.9 W PTC) Multi-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 17.26% efficiency, 46.2 V Voc at 25 C, and 51.97 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
335.0 W
PTC Wattage
304.9 W
Voc @ 25C
46.2 V
Efficiency
17.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-335P/156-72S Compare Against Peer CEC Listings?

How AXITEC AXITEC AC-335P/156-72S handles rooftop heat (304.9 W PTC), 8 kW sizing, and cold winter string voltage.

AXITEC builds the AXITEC AC-335P/156-72S (Multi-c-Si) as a compact residential or specialty off-grid module delivering 172.7 W/m2 (2.65 percentage points below 19.91% CEC median). Compared against Flextronics FXS-335BB-SAD1W (335.0 W), this model holds typical 91.0% PTC-to-STC thermal output (304.9 W real-world rating). Mid-range 46.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.57 A overcurrent floor served by a 15 A breaker.

Where Does AXITEC AC-335P/156-72S Fall Across Listed CEC Models?

Where AXITEC AC-335P/156-72S (335.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-335P/156-72S (335.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-335P/156: 335.0 W

What Dataset Percentiles Define AXITEC AC-335P/156-72S?

Percentile placement of AXITEC AC-335P/156-72S across power density (172.7 W/m2), thermal retention, and nameplate STC wattage.

AXITEC AC-335P/156-72S Engineering BenchmarksPercentile comparison of AXITEC AC-335P/156-72S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage335.0 WPTC/STC Retention91.0%Module Efficiency17.26%

What Do the Dataset Ranks Show for AXITEC AC-335P/156-72S?

Four critical engineering numbers homeowners and solar installers check first when reviewing AXITEC AC-335P/156-72S specifications. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Rank #13,844 / 21,677

335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,118

17.26% Aperture Efficiency

Power density 172.7 W/m2 (2.65 percentage points below 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.97 V at -10 C (571.7 V string) and 53.62 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,040 W STC

Occupies 46.6 m2 (501 sq ft) producing 7,318 W PTC; NEC 690.8 OCPD floor is 14.57 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.2 * (1 + (-0.357/100) * (-10 - 25)) = 51.97 V | OCPD = 1.56 * 9.34 = 14.57 A

Inputs from CEC Modules.csv for AXITEC AC-335P/156-72S: Voc=46.2 V, beta_Voc=-0.357%/C, Isc=9.34 A, STC=335.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (571.7 V); 24 panels for 8 kW (501 sq ft).

What Are the Published CEC Specifications for AXITEC AC-335P/156-72S?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AXITEC AC-335P/156-72S.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-335P/156-72S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 335.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 304.9 W (91.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.34 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.0 V / 8.82 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.357 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.26% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many AXITEC AC-335P/156-72S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AXITEC AC-335P/156-72S (335.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.03 kW 376 sq ft $1,509 $2,552
8 kW Class 24 8.04 kW 501 sq ft $2,012 $3,403
10 kW Class 30 10.05 kW 626 sq ft $2,515 $4,253

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

All closely matched AXITEC wattages and cosmetic trims sharing the AXITEC AC-335P/156-72S architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the AXITEC AC-335P/156-72S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-325P/156-72S 325.0 W 295.5 W 45.7 V 37.4 V 16.75%
AXITEC AC-330P/156-72S 330.0 W 300.2 W 45.9 V 37.7 V 17.01%
AXITEC AC-335P/156-72S 335.0 W 304.9 W 46.2 V 38.0 V 17.26%
AXITEC AC-340P/156-72S 340.0 W 309.6 W 46.4 V 38.3 V 17.52%
AXITEC AC-345P/156-72S 345.0 W 314.3 W 46.6 V 38.6 V 17.78%

How Many AXITEC AC-335P/156-72S Modules Fit in a Cold-Weather String?

Maximum series module counts for AXITEC AC-335P/156-72S from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.2V and beta_Voc=-0.357%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.62 V 11 panels 589.8 V 18 panels
-10 C (14 F) 51.97 V 11 panels 571.7 V 19 panels
0 C (32 F) 50.32 V 11 panels 553.5 V 19 panels
25 C (77 F STC) 46.2 V 12 panels 554.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-335P/156-72S?

Alternative CEC solar modules from competing brands near AXITEC AC-335P/156-72S (335.0 W), including Flextronics FXS-335BB-SAD1W. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Flextronics FXS-335BB-SAD1W
Flextronics
335.0 W Tie (0 W) 46.2 V 17.13% 91.2%
Boviet Solar Technology Co Ltd BVM6612P-335
Boviet Solar Technology Co Ltd
335.0 W Tie (0 W) 46.1 V 17.27% 92.5%
Boviet Solar Technology Co Ltd BVM6612M-335
Boviet Solar Technology Co Ltd
335.0 W Tie (0 W) 46.4 V 17.27% 91.7%
GCL System Integration Technology Co Ltd GCL-M6/72335
GCL System Integration Technology Co Ltd
335.0 W Tie (0 W) 46.4 V 17.27% 90.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-335P/156-72S?

Evaluate AXITEC AC-335P/156-72S (335.0 W STC, 46.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-335P/156-72S reaches 53.62 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 501 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (501 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-335P/156-72S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-335P/156-72S 8 kW Residential Fit

Needs 24 modules (501 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Flextronics FXS-335BB-SAD1W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 304.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-335P/156-72S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for AXITEC AC-335P/156-72S?

Multiplying AXITEC AC-335P/156-72S's 9.34 A short-circuit current by 1.56 equals 14.57 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can AXITEC AC-335P/156-72S pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.97 V cold Voc at 14 F and handles 9.34 A Isc; string inverters cap AXITEC AC-335P/156-72S at 11 panels on 600 V.

Is AXITEC AC-335P/156-72S eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AXITEC AC-335P/156-72S rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.