Hansol Technics Co Ltd HS335PD-AN1 is a 335.0 W STC (308.4 W PTC) Multi-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 17.45% efficiency, 46.5 V Voc at 25 C, and 51.35 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 335.0 W
- PTC Wattage
- 308.4 W
- Voc @ 25C
- 46.5 V
- Efficiency
- 17.45%
How Does Hansol Technics Co Ltd HS335PD-AN1 Compare Against Peer CEC Listings?
Solar engineering breakdown for Hansol Technics Co Ltd HS335PD-AN1: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from Hansol Technics Co Ltd and peers, Hansol Technics Co Ltd HS335PD-AN1 stands 56.2 W above the 278.8 W Multi-c-Si median and strong 92.1% PTC-to-STC heat retention (#13,846 of 21,677). Sizing 6 kW (18 panels) to 10 kW (30 panels) yields $1,509-$2,515/yr in baseline US bill offset. Mid-range 46.5 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Hansol Technics Co Ltd HS335PD-AN1 Fall Across Listed CEC Models?
Distribution marker showing Hansol Technics Co Ltd HS335PD-AN1 (335.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS335PD-AN1?
Dataset percentiles tracking Hansol Technics Co Ltd HS335PD-AN1 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS335PD-AN1?
Benchmark highlights for Hansol Technics Co Ltd HS335PD-AN1 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
335.0 W STC · Higher Than 34.7%
335.0 W STC (-50.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
17.45% Aperture Efficiency
Power density 174.5 W/m2 (2.46 percentage points below 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.35 V at -10 C (564.9 V string) and 52.74 V at -20 C (11 max).
24 Panels = 8,040 W STC
Occupies 46.1 m2 (496 sq ft) producing 7,402 W PTC; NEC 690.8 OCPD floor is 14.41 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.5 * (1 + (-0.298/100) * (-10 - 25)) = 51.35 V | OCPD = 1.56 * 9.24 = 14.41 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS335PD-AN1: Voc=46.5 V, beta_Voc=-0.298%/C, Isc=9.24 A, STC=335.0 W, Area=1.92 m2.
Result: 11 panels max on 600 V (564.9 V); 24 panels for 8 kW (496 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS335PD-AN1?
Official CEC datasheet figures for Hansol Technics Co Ltd HS335PD-AN1 (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 335.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 308.4 W (92.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.24 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.8 V / 8.87 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.298 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.45% (1.92 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS335PD-AN1 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hansol Technics Co Ltd HS335PD-AN1 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.03 kW | 372 sq ft | $1,509 | $2,552 |
| 8 kW Class | 24 | 8.04 kW | 496 sq ft | $2,012 | $3,403 |
| 10 kW Class | 30 | 10.05 kW | 620 sq ft | $2,515 | $4,253 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Consolidated Hansol Technics Co Ltd wattage variants sharing the Hansol Technics Co Ltd HS335PD-AN1 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS325PD-AN1 | 325.0 W | 299.0 W | 45.7 V | 37.0 V | 16.93% |
| Hansol Technics Co Ltd HS330PD-AN1 | 330.0 W | 303.7 W | 46.1 V | 37.4 V | 17.19% |
| Hansol Technics Co Ltd HS335PD-AN1 | 335.0 W | 308.4 W | 46.5 V | 37.8 V | 17.45% |
| Hansol Technics Co Ltd HS340PD-AN1 | 340.0 W | 313.2 W | 46.9 V | 38.2 V | 17.71% |
| Hansol Technics Co Ltd HS345PD-AN1 | 345.0 W | 317.9 W | 47.3 V | 38.6 V | 17.97% |
How Many Hansol Technics Co Ltd HS335PD-AN1 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS335PD-AN1 (51.35 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.74 V | 11 panels | 580.1 V | 18 panels |
| -10 C (14 F) | 51.35 V | 11 panels | 564.9 V | 19 panels |
| 0 C (32 F) | 49.96 V | 12 panels | 599.5 V | 20 panels |
| 25 C (77 F STC) | 46.5 V | 12 panels | 558.0 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS335PD-AN1?
Competing CEC solar panels closest to Hansol Technics Co Ltd HS335PD-AN1 in nameplate wattage and Voc, starting with AXITEC AC-335P/72X.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-335P/72X AXITEC |
335.0 W | Tie (0 W) | 46.45 V | 17.36% | 90.8% |
| AXITEC AC-335P/72XV AXITEC |
335.0 W | Tie (0 W) | 46.45 V | 17.36% | 90.8% |
| Boviet Solar Technology Co Ltd BVM6612M-335 Boviet Solar Technology Co Ltd |
335.0 W | Tie (0 W) | 46.4 V | 17.27% | 91.7% |
| GCL System Integration Technology Co Ltd GCL-M6/72335 GCL System Integration Technology Co Ltd |
335.0 W | Tie (0 W) | 46.4 V | 17.27% | 90.4% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS335PD-AN1?
Evaluate Hansol Technics Co Ltd HS335PD-AN1 (335.0 W STC, 46.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS335PD-AN1 reaches 52.74 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 496 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (496 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS335PD-AN1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS335PD-AN1 8 kW Residential Fit
Needs 24 modules (496 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-335P/72X.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 308.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS335PD-AN1 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS335PD-AN1?
Multiplying Hansol Technics Co Ltd HS335PD-AN1's 9.24 A short-circuit current by 1.56 equals 14.41 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HS335PD-AN1 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.35 V cold Voc at 14 F and handles 9.24 A Isc; string inverters cap Hansol Technics Co Ltd HS335PD-AN1 at 11 panels on 600 V.
Is Hansol Technics Co Ltd HS335PD-AN1 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS335PD-AN1 rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)