Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HS335PD-AN1 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS335PD-AN1 is a 335.0 W STC (308.4 W PTC) Multi-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 17.45% efficiency, 46.5 V Voc at 25 C, and 51.35 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
335.0 W
PTC Wattage
308.4 W
Voc @ 25C
46.5 V
Efficiency
17.45%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS335PD-AN1 Compare Against Peer CEC Listings?

Solar engineering breakdown for Hansol Technics Co Ltd HS335PD-AN1: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 1,407 Multi-c-Si listings from Hansol Technics Co Ltd and peers, Hansol Technics Co Ltd HS335PD-AN1 stands 56.2 W above the 278.8 W Multi-c-Si median and strong 92.1% PTC-to-STC heat retention (#13,846 of 21,677). Sizing 6 kW (18 panels) to 10 kW (30 panels) yields $1,509-$2,515/yr in baseline US bill offset. Mid-range 46.5 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Hansol Technics Co Ltd HS335PD-AN1 Fall Across Listed CEC Models?

Distribution marker showing Hansol Technics Co Ltd HS335PD-AN1 (335.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS335PD-AN1 (335.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 335.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS335PD-AN1?

Dataset percentiles tracking Hansol Technics Co Ltd HS335PD-AN1 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Hansol Technics Co Ltd HS335PD-AN1 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS335PD-AN1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage335.0 WPTC/STC Retention92.1%Module Efficiency17.45%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS335PD-AN1?

Benchmark highlights for Hansol Technics Co Ltd HS335PD-AN1 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #13,844 / 21,677

335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,846

17.45% Aperture Efficiency

Power density 174.5 W/m2 (2.46 percentage points below 19.91% CEC median). PTC/STC ratio: 92.1% (rank #13,846).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.35 V at -10 C (564.9 V string) and 52.74 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,040 W STC

Occupies 46.1 m2 (496 sq ft) producing 7,402 W PTC; NEC 690.8 OCPD floor is 14.41 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.5 * (1 + (-0.298/100) * (-10 - 25)) = 51.35 V | OCPD = 1.56 * 9.24 = 14.41 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS335PD-AN1: Voc=46.5 V, beta_Voc=-0.298%/C, Isc=9.24 A, STC=335.0 W, Area=1.92 m2.

Result: 11 panels max on 600 V (564.9 V); 24 panels for 8 kW (496 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS335PD-AN1?

Official CEC datasheet figures for Hansol Technics Co Ltd HS335PD-AN1 (Multi-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS335PD-AN1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 335.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 308.4 W (92.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.24 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.8 V / 8.87 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.298 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.45% (1.92 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS335PD-AN1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hansol Technics Co Ltd HS335PD-AN1 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.03 kW 372 sq ft $1,509 $2,552
8 kW Class 24 8.04 kW 496 sq ft $2,012 $3,403
10 kW Class 30 10.05 kW 620 sq ft $2,515 $4,253

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Consolidated Hansol Technics Co Ltd wattage variants sharing the Hansol Technics Co Ltd HS335PD-AN1 mechanical and cell layout.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS335PD-AN1 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS325PD-AN1 325.0 W 299.0 W 45.7 V 37.0 V 16.93%
Hansol Technics Co Ltd HS330PD-AN1 330.0 W 303.7 W 46.1 V 37.4 V 17.19%
Hansol Technics Co Ltd HS335PD-AN1 335.0 W 308.4 W 46.5 V 37.8 V 17.45%
Hansol Technics Co Ltd HS340PD-AN1 340.0 W 313.2 W 46.9 V 38.2 V 17.71%
Hansol Technics Co Ltd HS345PD-AN1 345.0 W 317.9 W 47.3 V 38.6 V 17.97%

How Many Hansol Technics Co Ltd HS335PD-AN1 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS335PD-AN1 (51.35 V at 14 F).

Computed from Voc=46.5V and beta_Voc=-0.298%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.74 V 11 panels 580.1 V 18 panels
-10 C (14 F) 51.35 V 11 panels 564.9 V 19 panels
0 C (32 F) 49.96 V 12 panels 599.5 V 20 panels
25 C (77 F STC) 46.5 V 12 panels 558.0 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS335PD-AN1?

Competing CEC solar panels closest to Hansol Technics Co Ltd HS335PD-AN1 in nameplate wattage and Voc, starting with AXITEC AC-335P/72X.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-335P/72X
AXITEC
335.0 W Tie (0 W) 46.45 V 17.36% 90.8%
AXITEC AC-335P/72XV
AXITEC
335.0 W Tie (0 W) 46.45 V 17.36% 90.8%
Boviet Solar Technology Co Ltd BVM6612M-335
Boviet Solar Technology Co Ltd
335.0 W Tie (0 W) 46.4 V 17.27% 91.7%
GCL System Integration Technology Co Ltd GCL-M6/72335
GCL System Integration Technology Co Ltd
335.0 W Tie (0 W) 46.4 V 17.27% 90.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS335PD-AN1?

Evaluate Hansol Technics Co Ltd HS335PD-AN1 (335.0 W STC, 46.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS335PD-AN1 reaches 52.74 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 496 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (496 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS335PD-AN1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS335PD-AN1 8 kW Residential Fit

Needs 24 modules (496 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-335P/72X.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 308.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS335PD-AN1 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS335PD-AN1?

Multiplying Hansol Technics Co Ltd HS335PD-AN1's 9.24 A short-circuit current by 1.56 equals 14.41 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Hansol Technics Co Ltd HS335PD-AN1 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.35 V cold Voc at 14 F and handles 9.24 A Isc; string inverters cap Hansol Technics Co Ltd HS335PD-AN1 at 11 panels on 600 V.

Is Hansol Technics Co Ltd HS335PD-AN1 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS335PD-AN1 rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.