Hansol Technics Co Ltd HS325ME-V01 is a 325.0 W STC (292.7 W PTC) Multi-c-Si solar module ranking #14,546 of 21,677 CEC listings (below all-CEC median; higher than 31.1% of peers). It delivers 16.99% efficiency, 45.6 V Voc at 25 C, and 50.87 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 325.0 W
- PTC Wattage
- 292.7 W
- Voc @ 25C
- 45.6 V
- Efficiency
- 16.99%
How Does Hansol Technics Co Ltd HS325ME-V01 Compare Against Peer CEC Listings?
Solar engineering breakdown for Hansol Technics Co Ltd HS325ME-V01: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 325.0 W STC and 292.7 W PTC, Hansol Technics Co Ltd HS325ME-V01 sits -60.0 W vs all-CEC median (below all-CEC median; higher than 31.1% of peers) among 21,677 listed modules. Power density reaches 169.9 W/m2 (2.92 percentage points below 19.91% CEC median). Mid-range 45.6 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Flextronics FXS-325BB-MAB1W rates 325.0 W.
Where Does Hansol Technics Co Ltd HS325ME-V01 Fall Across Listed CEC Models?
Distribution marker showing Hansol Technics Co Ltd HS325ME-V01 (325.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS325ME-V01?
Dataset percentiles tracking Hansol Technics Co Ltd HS325ME-V01 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS325ME-V01?
Benchmark highlights for Hansol Technics Co Ltd HS325ME-V01 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
325.0 W STC · Higher Than 31.1%
325.0 W STC (-60.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.99% Aperture Efficiency
Power density 169.9 W/m2 (2.92 percentage points below 19.91% CEC median). PTC/STC ratio: 90.1% (rank #18,772).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.87 V at -10 C (559.6 V string) and 52.37 V at -20 C (11 max).
25 Panels = 8,125 W STC
Occupies 47.8 m2 (515 sq ft) producing 7,318 W PTC; NEC 690.8 OCPD floor is 14.49 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.6 * (1 + (-0.33/100) * (-10 - 25)) = 50.87 V | OCPD = 1.56 * 9.29 = 14.49 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS325ME-V01: Voc=45.6 V, beta_Voc=-0.33%/C, Isc=9.29 A, STC=325.0 W, Area=1.913 m2.
Result: 11 panels max on 600 V (559.6 V); 25 panels for 8 kW (515 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS325ME-V01?
Official CEC datasheet figures for Hansol Technics Co Ltd HS325ME-V01 (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 325.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 292.7 W (90.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.29 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.1 V / 8.77 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.99% (1.913 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS325ME-V01 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hansol Technics Co Ltd HS325ME-V01 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.17 kW | 391 sq ft | $1,544 | $2,611 |
| 8 kW Class | 25 | 8.12 kW | 515 sq ft | $2,032 | $3,437 |
| 10 kW Class | 31 | 10.07 kW | 638 sq ft | $2,520 | $4,262 |
How Many Hansol Technics Co Ltd HS325ME-V01 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS325ME-V01 (50.87 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.37 V | 11 panels | 576.1 V | 19 panels |
| -10 C (14 F) | 50.87 V | 11 panels | 559.6 V | 19 panels |
| 0 C (32 F) | 49.36 V | 12 panels | 592.3 V | 20 panels |
| 25 C (77 F STC) | 45.6 V | 13 panels | 592.8 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS325ME-V01?
Competing CEC solar panels closest to Hansol Technics Co Ltd HS325ME-V01 in nameplate wattage and Voc, starting with Flextronics FXS-325BB-MAB1W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Flextronics FXS-325BB-MAB1W Flextronics |
325.0 W | Tie (0 W) | 45.8 V | 17.55% | 91.6% |
| Flextronics FXS-325BC-MAB1W Flextronics |
325.0 W | Tie (0 W) | 45.8 V | 17.55% | 91.6% |
| CertainTeed CT325P00-01 CertainTeed |
325.0 W | Tie (0 W) | 45.9 V | 17.96% | 91.8% |
| Chinaland Solar Energy HSE325-72M Chinaland Solar Energy |
325.0 W | Tie (0 W) | 45.9 V | 16.84% | 90.4% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS325ME-V01?
Evaluate Hansol Technics Co Ltd HS325ME-V01 (325.0 W STC, 45.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS325ME-V01 reaches 52.37 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 515 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (515 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS325ME-V01 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS325ME-V01 8 kW Residential Fit
Needs 25 modules (515 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Flextronics FXS-325BB-MAB1W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 292.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS325ME-V01 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hansol Technics Co Ltd HS325ME-V01 panels fit on a 600 V winter solar string?
At -10 C (14 F), Hansol Technics Co Ltd HS325ME-V01 cold Voc rises from 45.6 V to 50.87 V (beta_Voc -0.33%/C), capping a 600 V string at 11 panels (559.6 V).
How much roof area does an 8 kW array of Hansol Technics Co Ltd HS325ME-V01 need?
An 8 kW DC system uses 25 Hansol Technics Co Ltd HS325ME-V01 modules (8,125 W STC / 7,318 W PTC), covering roughly 515 sq ft and saving ~$2,032/yr at 18.54 c/kWh.
How does Hansol Technics Co Ltd HS325ME-V01 compare against Flextronics FXS-325BB-MAB1W?
Hansol Technics Co Ltd HS325ME-V01 outputs 325.0 W STC (45.6 V Voc, rank #14,546 of 21,677), while Flextronics FXS-325BB-MAB1W delivers 325.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)