Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HS310UB-AN1 {Wht} — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS310UB-AN1 {Wht} is a 310.0 W STC (284.1 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 19.25% efficiency, 41.1 V Voc at 25 C, and 45.16 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
284.1 W
Voc @ 25C
41.1 V
Efficiency
19.25%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS310UB-AN1 {Wht} Compare Against Peer CEC Listings?

Solar engineering breakdown for Hansol Technics Co Ltd HS310UB-AN1 {Wht}: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 310.0 W STC and 284.1 W PTC, Hansol Technics Co Ltd HS310UB-AN1 {Wht} sits -75.0 W vs all-CEC median (below all-CEC median; higher than 25.6% of peers) among 21,677 listed modules. Power density reaches 192.5 W/m2 (0.66 percentage points below 19.91% CEC median). Mid-range 41.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer Auxin Solar AXN6M610T310 rates 310.0 W.

Where Does Hansol Technics Co Ltd HS310UB-AN1 {Wht} Fall Across Listed CEC Models?

Distribution marker showing Hansol Technics Co Ltd HS310UB-AN1 {Wht} (310.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS310UB-AN1 {Wht} (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 310.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS310UB-AN1 {Wht}?

Dataset percentiles tracking Hansol Technics Co Ltd HS310UB-AN1 {Wht} power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Hansol Technics Co Ltd HS310UB-AN1 {Wht} Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS310UB-AN1 {Wht} wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention91.6%Module Efficiency19.25%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS310UB-AN1 {Wht}?

Benchmark highlights for Hansol Technics Co Ltd HS310UB-AN1 {Wht} covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,863

19.25% Aperture Efficiency

Power density 192.5 W/m2 (0.66 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 45.16 V at -10 C (587.1 V string) and 46.32 V at -20 C (12 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 41.9 m2 (451 sq ft) producing 7,387 W PTC; NEC 690.8 OCPD floor is 15.33 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.1 * (1 + (-0.282/100) * (-10 - 25)) = 45.16 V | OCPD = 1.56 * 9.83 = 15.33 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS310UB-AN1 {Wht}: Voc=41.1 V, beta_Voc=-0.282%/C, Isc=9.83 A, STC=310.0 W, Area=1.61 m2.

Result: 13 panels max on 600 V (587.1 V); 26 panels for 8 kW (451 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS310UB-AN1 {Wht}?

Official CEC datasheet figures for Hansol Technics Co Ltd HS310UB-AN1 {Wht} (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS310UB-AN1 {Wht}.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 284.1 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.83 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.3 V / 9.32 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.282 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.25% (1.61 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS310UB-AN1 {Wht} Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hansol Technics Co Ltd HS310UB-AN1 {Wht} modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 347 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 451 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 572 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Consolidated Hansol Technics Co Ltd wattage variants sharing the Hansol Technics Co Ltd HS310UB-AN1 {Wht} mechanical and cell layout.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS310UB-AN1 {Wht} wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS300UB-AN1 {Wht} 300.0 W 274.6 W 40.3 V 32.5 V 18.63%
Hansol Technics Co Ltd HS305UB-AN1 {Wht} 305.0 W 279.3 W 40.7 V 32.9 V 18.94%
Hansol Technics Co Ltd HS310UB-AN1 {Wht} 310.0 W 284.1 W 41.1 V 33.3 V 19.25%
Hansol Technics Co Ltd HS315UB-AN1 {Wht} 315.0 W 288.8 W 41.5 V 33.7 V 19.57%
Hansol Technics Co Ltd HS320UB-AN1 {Wht} 320.0 W 293.5 W 41.9 V 34.1 V 19.88%

How Many Hansol Technics Co Ltd HS310UB-AN1 {Wht} Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS310UB-AN1 {Wht} (45.16 V at 14 F).

Computed from Voc=41.1V and beta_Voc=-0.282%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 46.32 V 12 panels 555.8 V 21 panels
-10 C (14 F) 45.16 V 13 panels 587.1 V 22 panels
0 C (32 F) 44.0 V 13 panels 572.0 V 22 panels
25 C (77 F STC) 41.1 V 14 panels 575.4 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS310UB-AN1 {Wht}?

Competing CEC solar panels closest to Hansol Technics Co Ltd HS310UB-AN1 {Wht} in nameplate wattage and Voc, starting with Auxin Solar AXN6M610T310.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M610T310
Auxin Solar
310.0 W Tie (0 W) 41.14 V 19.05% 91.8%
CertainTeed CT310M11-02
CertainTeed
310.0 W Tie (0 W) 41.14 V 19.68% 91.4%
DualSun SAS DualSun 310M-60-00
DualSun SAS
310.0 W Tie (0 W) 40.3 V 18.9% 91.4%
CSI Solar Co Ltd CS6XH-310P
CSI Solar Co Ltd
310.0 W Tie (0 W) 42.0 V 16.76% 92.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS310UB-AN1 {Wht}?

Evaluate Hansol Technics Co Ltd HS310UB-AN1 {Wht} (310.0 W STC, 41.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS310UB-AN1 {Wht} reaches 46.32 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 451 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (451 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS310UB-AN1 {Wht} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS310UB-AN1 {Wht} 8 kW Residential Fit

Needs 26 modules (451 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Auxin Solar AXN6M610T310.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 284.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS310UB-AN1 {Wht} by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Hansol Technics Co Ltd HS310UB-AN1 {Wht} panels fit on a 600 V winter solar string?

At -10 C (14 F), Hansol Technics Co Ltd HS310UB-AN1 {Wht} cold Voc rises from 41.1 V to 45.16 V (beta_Voc -0.282%/C), capping a 600 V string at 13 panels (587.1 V).

How much roof area does an 8 kW array of Hansol Technics Co Ltd HS310UB-AN1 {Wht} need?

An 8 kW DC system uses 26 Hansol Technics Co Ltd HS310UB-AN1 {Wht} modules (8,060 W STC / 7,387 W PTC), covering roughly 451 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does Hansol Technics Co Ltd HS310UB-AN1 {Wht} compare against Auxin Solar AXN6M610T310?

Hansol Technics Co Ltd HS310UB-AN1 {Wht} outputs 310.0 W STC (41.1 V Voc, rank #15,760 of 21,677), while Auxin Solar AXN6M610T310 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?