Hansol Technics Co Ltd HS310UB-AN1 {Wht} is a 310.0 W STC (284.1 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 19.25% efficiency, 41.1 V Voc at 25 C, and 45.16 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 284.1 W
- Voc @ 25C
- 41.1 V
- Efficiency
- 19.25%
How Does Hansol Technics Co Ltd HS310UB-AN1 {Wht} Compare Against Peer CEC Listings?
Solar engineering breakdown for Hansol Technics Co Ltd HS310UB-AN1 {Wht}: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 310.0 W STC and 284.1 W PTC, Hansol Technics Co Ltd HS310UB-AN1 {Wht} sits -75.0 W vs all-CEC median (below all-CEC median; higher than 25.6% of peers) among 21,677 listed modules. Power density reaches 192.5 W/m2 (0.66 percentage points below 19.91% CEC median). Mid-range 41.1 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer Auxin Solar AXN6M610T310 rates 310.0 W.
Where Does Hansol Technics Co Ltd HS310UB-AN1 {Wht} Fall Across Listed CEC Models?
Distribution marker showing Hansol Technics Co Ltd HS310UB-AN1 {Wht} (310.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS310UB-AN1 {Wht}?
Dataset percentiles tracking Hansol Technics Co Ltd HS310UB-AN1 {Wht} power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS310UB-AN1 {Wht}?
Benchmark highlights for Hansol Technics Co Ltd HS310UB-AN1 {Wht} covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.25% Aperture Efficiency
Power density 192.5 W/m2 (0.66 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.16 V at -10 C (587.1 V string) and 46.32 V at -20 C (12 max).
26 Panels = 8,060 W STC
Occupies 41.9 m2 (451 sq ft) producing 7,387 W PTC; NEC 690.8 OCPD floor is 15.33 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.1 * (1 + (-0.282/100) * (-10 - 25)) = 45.16 V | OCPD = 1.56 * 9.83 = 15.33 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS310UB-AN1 {Wht}: Voc=41.1 V, beta_Voc=-0.282%/C, Isc=9.83 A, STC=310.0 W, Area=1.61 m2.
Result: 13 panels max on 600 V (587.1 V); 26 panels for 8 kW (451 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS310UB-AN1 {Wht}?
Official CEC datasheet figures for Hansol Technics Co Ltd HS310UB-AN1 {Wht} (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 284.1 W (91.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.83 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.3 V / 9.32 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.282 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.25% (1.61 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS310UB-AN1 {Wht} Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hansol Technics Co Ltd HS310UB-AN1 {Wht} modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 347 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 451 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 572 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Consolidated Hansol Technics Co Ltd wattage variants sharing the Hansol Technics Co Ltd HS310UB-AN1 {Wht} mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS300UB-AN1 {Wht} | 300.0 W | 274.6 W | 40.3 V | 32.5 V | 18.63% |
| Hansol Technics Co Ltd HS305UB-AN1 {Wht} | 305.0 W | 279.3 W | 40.7 V | 32.9 V | 18.94% |
| Hansol Technics Co Ltd HS310UB-AN1 {Wht} | 310.0 W | 284.1 W | 41.1 V | 33.3 V | 19.25% |
| Hansol Technics Co Ltd HS315UB-AN1 {Wht} | 315.0 W | 288.8 W | 41.5 V | 33.7 V | 19.57% |
| Hansol Technics Co Ltd HS320UB-AN1 {Wht} | 320.0 W | 293.5 W | 41.9 V | 34.1 V | 19.88% |
How Many Hansol Technics Co Ltd HS310UB-AN1 {Wht} Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HS310UB-AN1 {Wht} (45.16 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.32 V | 12 panels | 555.8 V | 21 panels |
| -10 C (14 F) | 45.16 V | 13 panels | 587.1 V | 22 panels |
| 0 C (32 F) | 44.0 V | 13 panels | 572.0 V | 22 panels |
| 25 C (77 F STC) | 41.1 V | 14 panels | 575.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS310UB-AN1 {Wht}?
Competing CEC solar panels closest to Hansol Technics Co Ltd HS310UB-AN1 {Wht} in nameplate wattage and Voc, starting with Auxin Solar AXN6M610T310.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M610T310 Auxin Solar |
310.0 W | Tie (0 W) | 41.14 V | 19.05% | 91.8% |
| CertainTeed CT310M11-02 CertainTeed |
310.0 W | Tie (0 W) | 41.14 V | 19.68% | 91.4% |
| DualSun SAS DualSun 310M-60-00 DualSun SAS |
310.0 W | Tie (0 W) | 40.3 V | 18.9% | 91.4% |
| CSI Solar Co Ltd CS6XH-310P CSI Solar Co Ltd |
310.0 W | Tie (0 W) | 42.0 V | 16.76% | 92.8% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS310UB-AN1 {Wht}?
Evaluate Hansol Technics Co Ltd HS310UB-AN1 {Wht} (310.0 W STC, 41.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS310UB-AN1 {Wht} reaches 46.32 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 451 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (451 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS310UB-AN1 {Wht} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS310UB-AN1 {Wht} 8 kW Residential Fit
Needs 26 modules (451 sq ft) with a 20 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Auxin Solar AXN6M610T310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 284.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS310UB-AN1 {Wht} by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hansol Technics Co Ltd HS310UB-AN1 {Wht} panels fit on a 600 V winter solar string?
At -10 C (14 F), Hansol Technics Co Ltd HS310UB-AN1 {Wht} cold Voc rises from 41.1 V to 45.16 V (beta_Voc -0.282%/C), capping a 600 V string at 13 panels (587.1 V).
How much roof area does an 8 kW array of Hansol Technics Co Ltd HS310UB-AN1 {Wht} need?
An 8 kW DC system uses 26 Hansol Technics Co Ltd HS310UB-AN1 {Wht} modules (8,060 W STC / 7,387 W PTC), covering roughly 451 sq ft and saving ~$2,017/yr at 18.54 c/kWh.
How does Hansol Technics Co Ltd HS310UB-AN1 {Wht} compare against Auxin Solar AXN6M610T310?
Hansol Technics Co Ltd HS310UB-AN1 {Wht} outputs 310.0 W STC (41.1 V Voc, rank #15,760 of 21,677), while Auxin Solar AXN6M610T310 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)