Hansol Technics Co Ltd HS295ME-V01 is a 295.0 W STC (264.9 W PTC) Multi-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 15.42% efficiency, 45.0 V Voc at 25 C, and 50.2 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 295.0 W
- PTC Wattage
- 264.9 W
- Voc @ 25C
- 45.0 V
- Efficiency
- 15.42%
How Does Hansol Technics Co Ltd HS295ME-V01 Compare Against Peer CEC Listings?
How Hansol Technics Co Ltd Hansol Technics Co Ltd HS295ME-V01 handles rooftop heat (264.9 W PTC), 8 kW sizing, and cold winter string voltage.
Hansol Technics Co Ltd builds the Hansol Technics Co Ltd HS295ME-V01 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 154.2 W/m2 (4.49 percentage points below 19.91% CEC median). Compared against BYD Company Limited BYD295P6K-36 (295.0 W), this model holds typical 89.8% PTC-to-STC thermal output (264.9 W real-world rating). Mid-range 45.0 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.43 A overcurrent floor served by a 15 A breaker.
Where Does Hansol Technics Co Ltd HS295ME-V01 Fall Across Listed CEC Models?
Where Hansol Technics Co Ltd HS295ME-V01 (295.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HS295ME-V01?
Percentile placement of Hansol Technics Co Ltd HS295ME-V01 across power density (154.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS295ME-V01?
Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HS295ME-V01 specifications.
295.0 W STC · Higher Than 20.4%
295.0 W STC (-90.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.42% Aperture Efficiency
Power density 154.2 W/m2 (4.49 percentage points below 19.91% CEC median). PTC/STC ratio: 89.8% (rank #19,481).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.2 V at -10 C (552.2 V string) and 51.68 V at -20 C (11 max).
28 Panels = 8,260 W STC
Occupies 53.6 m2 (577 sq ft) producing 7,417 W PTC; NEC 690.8 OCPD floor is 13.43 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.0 * (1 + (-0.33/100) * (-10 - 25)) = 50.2 V | OCPD = 1.56 * 8.61 = 13.43 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS295ME-V01: Voc=45.0 V, beta_Voc=-0.33%/C, Isc=8.61 A, STC=295.0 W, Area=1.913 m2.
Result: 11 panels max on 600 V (552.2 V); 28 panels for 8 kW (577 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS295ME-V01?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HS295ME-V01.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 264.9 W (89.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.5 V / 8.09 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.33 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.42% (1.913 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS295ME-V01 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HS295ME-V01 (295.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.2 kW | 432 sq ft | $1,552 | $2,624 |
| 8 kW Class | 28 | 8.26 kW | 577 sq ft | $2,067 | $3,496 |
| 10 kW Class | 34 | 10.03 kW | 700 sq ft | $2,510 | $4,245 |
How Many Hansol Technics Co Ltd HS295ME-V01 Modules Fit in a Cold-Weather String?
Maximum series module counts for Hansol Technics Co Ltd HS295ME-V01 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.68 V | 11 panels | 568.5 V | 19 panels |
| -10 C (14 F) | 50.2 V | 11 panels | 552.2 V | 19 panels |
| 0 C (32 F) | 48.71 V | 12 panels | 584.5 V | 20 panels |
| 25 C (77 F STC) | 45.0 V | 13 panels | 585.0 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS295ME-V01?
Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HS295ME-V01 (295.0 W), including BYD Company Limited BYD295P6K-36.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| BYD Company Limited BYD295P6K-36 BYD Company Limited |
295.0 W | Tie (0 W) | 44.9 V | 15.21% | 91.5% |
| Centrosolar America TP7 295xx Centrosolar America |
295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
| Centrosolar America TP7S 295xx Centrosolar America |
295.0 W | Tie (0 W) | 45.1 V | 15.13% | 90.4% |
| Chinaland Solar Energy HSE295-72M Chinaland Solar Energy |
295.0 W | Tie (0 W) | 44.4 V | 15.28% | 90.2% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS295ME-V01?
Evaluate Hansol Technics Co Ltd HS295ME-V01 (295.0 W STC, 45.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS295ME-V01 reaches 51.68 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 577 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (577 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS295ME-V01 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS295ME-V01 8 kW Residential Fit
Needs 28 modules (577 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare BYD Company Limited BYD295P6K-36.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 264.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS295ME-V01 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS295ME-V01?
Multiplying Hansol Technics Co Ltd HS295ME-V01's 8.61 A short-circuit current by 1.56 equals 13.43 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HS295ME-V01 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.2 V cold Voc at 14 F and handles 8.61 A Isc; string inverters cap Hansol Technics Co Ltd HS295ME-V01 at 11 panels on 600 V.
Is Hansol Technics Co Ltd HS295ME-V01 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS295ME-V01 rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)