Hansol Technics Co Ltd HS290UB-AN1 {Wht} is a 290.0 W STC (265.2 W PTC) Mono-c-Si solar module ranking #17,253 of 21,677 CEC listings (below all-CEC median; higher than 18.8% of peers). It delivers 18.01% efficiency, 39.5 V Voc at 25 C, and 43.4 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 290.0 W
- PTC Wattage
- 265.2 W
- Voc @ 25C
- 39.5 V
- Efficiency
- 18.01%
How Does Hansol Technics Co Ltd HS290UB-AN1 {Wht} Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HS290UB-AN1 {Wht} (Mono-c-Si) residential solar systems.
Homeowners evaluating Hansol Technics Co Ltd HS290UB-AN1 {Wht} need 21 panels for 6 kW or 28 panels (485 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (485 sq ft). Under NEC 690.7(A), beta_Voc (-0.282%/C) pushes open-circuit voltage to 43.4 V at 14 F and 44.51 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Hansol Technics Co Ltd HS290UB-AN1 {Wht} Fall Across Listed CEC Models?
Comparison of Hansol Technics Co Ltd HS290UB-AN1 {Wht} (290.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Hansol Technics Co Ltd HS290UB-AN1 {Wht}?
Relative ranking of Hansol Technics Co Ltd HS290UB-AN1 {Wht} across nameplate watts, 91.4% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS290UB-AN1 {Wht}?
Summary of Hansol Technics Co Ltd HS290UB-AN1 {Wht} output rank, 8 kW array size (28 panels), efficiency rating, and 600 V string limit.
290.0 W STC · Higher Than 18.8%
290.0 W STC (-95.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.01% Aperture Efficiency
Power density 180.1 W/m2 (1.90 percentage points below 19.91% CEC median). PTC/STC ratio: 91.4% (rank #15,834).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.4 V at -10 C (564.2 V string) and 44.51 V at -20 C (13 max).
28 Panels = 8,120 W STC
Occupies 45.1 m2 (485 sq ft) producing 7,426 W PTC; NEC 690.8 OCPD floor is 15.09 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.5 * (1 + (-0.282/100) * (-10 - 25)) = 43.4 V | OCPD = 1.56 * 9.67 = 15.09 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS290UB-AN1 {Wht}: Voc=39.5 V, beta_Voc=-0.282%/C, Isc=9.67 A, STC=290.0 W, Area=1.61 m2.
Result: 13 panels max on 600 V (564.2 V); 28 panels for 8 kW (485 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HS290UB-AN1 {Wht}?
Complete CEC test sheet for Hansol Technics Co Ltd HS290UB-AN1 {Wht} including Isc (9.67 A), Voc (39.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 290.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 265.2 W (91.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.67 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.7 V / 9.16 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.282 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.01% (1.61 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HS290UB-AN1 {Wht} Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HS290UB-AN1 {Wht}.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.09 kW | 364 sq ft | $1,524 | $2,577 |
| 8 kW Class | 28 | 8.12 kW | 485 sq ft | $2,032 | $3,437 |
| 10 kW Class | 35 | 10.15 kW | 607 sq ft | $2,540 | $4,296 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Related Hansol Technics Co Ltd power steps and black/silver trims consolidated into this Hansol Technics Co Ltd HS290UB-AN1 {Wht} series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HS285UB-AN1 {Wht} | 285.0 W | 262.7 W | 39.1 V | 31.3 V | 17.07% |
| Hansol Technics Co Ltd HS290UB-AN1 {Wht} | 290.0 W | 265.2 W | 39.5 V | 31.7 V | 18.01% |
| Hansol Technics Co Ltd HS295UB-AN1 {Wht} | 295.0 W | 269.9 W | 39.9 V | 32.1 V | 18.32% |
How Many Hansol Technics Co Ltd HS290UB-AN1 {Wht} Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Hansol Technics Co Ltd HS290UB-AN1 {Wht} (39.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.51 V | 13 panels | 578.6 V | 22 panels |
| -10 C (14 F) | 43.4 V | 13 panels | 564.2 V | 23 panels |
| 0 C (32 F) | 42.28 V | 14 panels | 591.9 V | 23 panels |
| 25 C (77 F STC) | 39.5 V | 15 panels | 592.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS290UB-AN1 {Wht}?
Four comparable CEC modules such as AXITEC AC-290M/60S (290.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-290M/60S AXITEC |
290.0 W | Tie (0 W) | 39.42 V | 17.79% | 91.1% |
| AXITEC AC-290M/60V AXITEC |
290.0 W | Tie (0 W) | 39.42 V | 17.79% | 91.1% |
| DualSun SAS DualSun 290M-60-00 DualSun SAS |
290.0 W | Tie (0 W) | 39.7 V | 17.68% | 90.9% |
| CertainTeed CT290M10-02 CertainTeed |
290.0 W | Tie (0 W) | 39.77 V | 17.83% | 91.8% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS290UB-AN1 {Wht}?
Evaluate Hansol Technics Co Ltd HS290UB-AN1 {Wht} (290.0 W STC, 39.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS290UB-AN1 {Wht} reaches 44.51 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 485 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (485 sq ft).
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS290UB-AN1 {Wht} carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HS290UB-AN1 {Wht} 8 kW Residential Fit
Needs 28 modules (485 sq ft) with a 20 A string OCPD, offsetting ~$2,032/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-290M/60S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 265.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HS290UB-AN1 {Wht} by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Hansol Technics Co Ltd HS290UB-AN1 {Wht} PTC wattage (265.2 W) lower than STC (290.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 265.2 W PTC (91.4% retention) across Hansol Technics Co Ltd HS290UB-AN1 {Wht}'s 1.61 m2 aperture.
Who should skip Hansol Technics Co Ltd HS290UB-AN1 {Wht} on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 28 Hansol Technics Co Ltd HS290UB-AN1 {Wht} panels (485 sq ft) leave unusable roof gaps vs. AXITEC AC-290M/60S.
What is the 1,000 V commercial string limit for Hansol Technics Co Ltd HS290UB-AN1 {Wht}?
On 1,000 V commercial inverters at -10 C (43.4 V cold Voc), Hansol Technics Co Ltd HS290UB-AN1 {Wht} fits up to 23 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)