Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HS280PB-AN1 is a 280.0 W STC (258.3 W PTC) Multi-c-Si solar module ranking #17,941 of 21,677 CEC listings (below all-CEC median; higher than 15.8% of peers). It delivers 17.39% efficiency, 38.9 V Voc at 25 C, and 43.03 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
280.0 W
PTC Wattage
258.3 W
Voc @ 25C
38.9 V
Efficiency
17.39%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HS280PB-AN1 Compare Against Peer CEC Listings?

Engineering position of Hansol Technics Co Ltd HS280PB-AN1 (280.0 W STC) vs. Centrosolar America TM6 280xx across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, Hansol Technics Co Ltd HS280PB-AN1 pairs strong 92.2% PTC-to-STC heat retention (#13,542 of 21,677) with 38.9 V nominal Voc. An 8 kW residential build (8,120 W DC, 7,491 W PTC) saves ~$2,032/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Centrosolar America TM6 280xx offers a 280.0 W alternative.

Where Does Hansol Technics Co Ltd HS280PB-AN1 Fall Across Listed CEC Models?

Plots Hansol Technics Co Ltd HS280PB-AN1 at 280.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HS280PB-AN1 (280.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 280.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HS280PB-AN1?

Benchmarks Hansol Technics Co Ltd HS280PB-AN1 on STC wattage, thermal PTC/STC retention, and 17.39 aperture conversion efficiency against CEC peers.

Hansol Technics Co Ltd HS280PB-AN1 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HS280PB-AN1 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage280.0 WPTC/STC Retention92.2%Module Efficiency17.39%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HS280PB-AN1?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hansol Technics Co Ltd HS280PB-AN1 by Hansol Technics Co Ltd.

Rank #17,941 / 21,677

280.0 W STC · Higher Than 15.8%

280.0 W STC (-105.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,949

17.39% Aperture Efficiency

Power density 173.9 W/m2 (2.52 percentage points below 19.91% CEC median). PTC/STC ratio: 92.2% (rank #13,542).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.03 V at -10 C (559.4 V string) and 44.2 V at -20 C (13 max).

8 kW Reference Array

29 Panels = 8,120 W STC

Occupies 46.7 m2 (503 sq ft) producing 7,491 W PTC; NEC 690.8 OCPD floor is 14.38 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.9 * (1 + (-0.303/100) * (-10 - 25)) = 43.03 V | OCPD = 1.56 * 9.22 = 14.38 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HS280PB-AN1: Voc=38.9 V, beta_Voc=-0.303%/C, Isc=9.22 A, STC=280.0 W, Area=1.61 m2.

Result: 13 panels max on 600 V (559.4 V); 29 panels for 8 kW (503 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HS280PB-AN1?

Laboratory test ratings recorded for Hansol Technics Co Ltd HS280PB-AN1 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HS280PB-AN1.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 280.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 258.3 W (92.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.22 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.1 V / 8.73 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.303 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.39% (1.61 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HS280PB-AN1 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (503 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hansol Technics Co Ltd HS280PB-AN1.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.16 kW 381 sq ft $1,542 $2,607
8 kW Class 29 8.12 kW 503 sq ft $2,032 $3,437
10 kW Class 36 10.08 kW 624 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Sibling wattage bins and frame colors grouped with Hansol Technics Co Ltd HS280PB-AN1 under Hansol Technics Co Ltd to prevent duplicate spec pages.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HS280PB-AN1 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HS275PB-AN1 275.0 W 253.6 W 38.5 V 31.7 V 17.08%
Hansol Technics Co Ltd HS280PB-AN1 280.0 W 258.3 W 38.9 V 32.1 V 17.39%

How Many Hansol Technics Co Ltd HS280PB-AN1 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Hansol Technics Co Ltd HS280PB-AN1 (beta_Voc -0.303%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=38.9V and beta_Voc=-0.303%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.2 V 13 panels 574.6 V 22 panels
-10 C (14 F) 43.03 V 13 panels 559.4 V 23 panels
0 C (32 F) 41.85 V 14 panels 585.9 V 23 panels
25 C (77 F STC) 38.9 V 15 panels 583.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HS280PB-AN1?

Closest cross-brand CEC competitors to Hansol Technics Co Ltd HS280PB-AN1 matched near 280.0 W STC and 38.9 V Voc, led by Centrosolar America TM6 280xx.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America TM6 280xx
Centrosolar America
280.0 W Tie (0 W) 38.7 V 17.14% 90.6%
Centrosolar America TM6S 280xx
Centrosolar America
280.0 W Tie (0 W) 38.7 V 17.14% 90.6%
GCL System Integration Technology Co Ltd GCL-M6/60280
GCL System Integration Technology Co Ltd
280.0 W Tie (0 W) 38.7 V 17.18% 90.1%
GCL System Integration Technology Co Ltd GCL-P6/60280
GCL System Integration Technology Co Ltd
280.0 W Tie (0 W) 38.7 V 17.18% 90.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HS280PB-AN1?

Evaluate Hansol Technics Co Ltd HS280PB-AN1 (280.0 W STC, 38.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HS280PB-AN1 reaches 44.2 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 503 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (503 sq ft).
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HS280PB-AN1 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HS280PB-AN1 8 kW Residential Fit

Needs 29 modules (503 sq ft) with a 15 A string OCPD, offsetting ~$2,032/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Centrosolar America TM6 280xx.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 258.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HS280PB-AN1 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HS280PB-AN1?

Multiplying Hansol Technics Co Ltd HS280PB-AN1's 9.22 A short-circuit current by 1.56 equals 14.38 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Hansol Technics Co Ltd HS280PB-AN1 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.03 V cold Voc at 14 F and handles 9.22 A Isc; string inverters cap Hansol Technics Co Ltd HS280PB-AN1 at 13 panels on 600 V.

Is Hansol Technics Co Ltd HS280PB-AN1 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HS280PB-AN1 rely on utility bill offset (~$2,032/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.