Hansol Technics Co Ltd HA585AD-NGEA0 is a 585.0 W STC (556.5 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.85% efficiency, 51.2 V Voc at 25 C, and 55.59 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 585.0 W
- PTC Wattage
- 556.5 W
- Voc @ 25C
- 51.2 V
- Efficiency
- 22.85%
How Does Hansol Technics Co Ltd HA585AD-NGEA0 Compare Against Peer CEC Listings?
Engineering position of Hansol Technics Co Ltd HA585AD-NGEA0 (585.0 W STC) vs. Chint New Energy Technology Co Ltd CHSM72N-HC-585 across 5,889 CEC Mono-c-Si solar modules.
Ranking #1,751 across 21,677 CEC solar panels (top 8.7%; higher than 91.3% of peers), Hansol Technics Co Ltd HA585AD-NGEA0 operates as a large-format commercial and ground-mount module sitting 175.0 W above the 410.0 W Mono-c-Si median. Higher 51.2 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C). With strong 95.1% PTC-to-STC heat retention (#713 of 21,677), 14 panels occupy 386 sq ft and offset roughly $2,050/yr at average US rates (or $3,466/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Hansol Technics Co Ltd HA585AD-NGEA0 Fall Across Listed CEC Models?
Plots Hansol Technics Co Ltd HA585AD-NGEA0 at 585.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HA585AD-NGEA0?
Benchmarks Hansol Technics Co Ltd HA585AD-NGEA0 on STC wattage, thermal PTC/STC retention, and 22.85 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA585AD-NGEA0?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hansol Technics Co Ltd HA585AD-NGEA0 by Hansol Technics Co Ltd.
Top 8.7% STC Output
585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.85% Aperture Efficiency
Power density 228.5 W/m2 (2.94 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.59 V at -10 C (555.9 V string) and 56.84 V at -20 C (10 max).
14 Panels = 8,190 W STC
Occupies 35.8 m2 (386 sq ft) producing 7,791 W PTC; NEC 690.8 OCPD floor is 22.7 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 51.2 * (1 + (-0.245/100) * (-10 - 25)) = 55.59 V | OCPD = 1.56 * 14.55 = 22.7 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA585AD-NGEA0: Voc=51.2 V, beta_Voc=-0.245%/C, Isc=14.55 A, STC=585.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (555.9 V); 14 panels for 8 kW (386 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HA585AD-NGEA0?
Laboratory test ratings recorded for Hansol Technics Co Ltd HA585AD-NGEA0 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 556.5 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 51.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.5 V / 13.76 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.245 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.85% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HA585AD-NGEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (386 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hansol Technics Co Ltd HA585AD-NGEA0.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.43 kW | 303 sq ft | $1,609 | $2,721 |
| 8 kW Class | 14 | 8.19 kW | 386 sq ft | $2,050 | $3,466 |
| 10 kW Class | 18 | 10.53 kW | 496 sq ft | $2,636 | $4,457 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Sibling wattage bins and frame colors grouped with Hansol Technics Co Ltd HA585AD-NGEA0 under Hansol Technics Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HA575AD-NGEA0 | 575.0 W | 546.8 W | 50.9 V | 42.2 V | 22.46% |
| Hansol Technics Co Ltd HA580AD-NGEA0 | 580.0 W | 551.7 W | 51.0 V | 42.4 V | 22.66% |
| Hansol Technics Co Ltd HA585AD-NGEA0 | 585.0 W | 556.5 W | 51.2 V | 42.5 V | 22.85% |
| Hansol Technics Co Ltd HA590AD-NGEA0 | 590.0 W | 561.4 W | 51.3 V | 42.7 V | 23.05% |
How Many Hansol Technics Co Ltd HA585AD-NGEA0 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Hansol Technics Co Ltd HA585AD-NGEA0 (beta_Voc -0.245%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.84 V | 10 panels | 568.4 V | 17 panels |
| -10 C (14 F) | 55.59 V | 10 panels | 555.9 V | 17 panels |
| 0 C (32 F) | 54.34 V | 11 panels | 597.7 V | 18 panels |
| 25 C (77 F STC) | 51.2 V | 11 panels | 563.2 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA585AD-NGEA0?
Closest cross-brand CEC competitors to Hansol Technics Co Ltd HA585AD-NGEA0 matched near 585.0 W STC and 51.2 V Voc, led by Chint New Energy Technology Co Ltd CHSM72N-HC-585.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Chint New Energy Technology Co Ltd CHSM72N-HC-585 Chint New Energy Technology Co Ltd |
585.0 W | Tie (0 W) | 51.3 V | 22.67% | 94.7% |
| AE Solar GmbH AE585CMD-144BDS AE Solar GmbH |
585.0 W | Tie (0 W) | 51.6 V | 22.67% | 95.3% |
| DE SOLAR(S) PTE LTD DE585-144BG-182S-N/WW DE SOLAR(S) PTE LTD |
585.0 W | Tie (0 W) | 51.6 V | 22.67% | 95.3% |
| ELITE Solar ET-N772TBH585GB ELITE Solar |
585.0 W | Tie (0 W) | 52.28 V | 22.67% | 94.8% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA585AD-NGEA0?
Evaluate Hansol Technics Co Ltd HA585AD-NGEA0 (585.0 W STC, 51.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA585AD-NGEA0 reaches 56.84 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA585AD-NGEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HA585AD-NGEA0 8 kW Residential Fit
Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Chint New Energy Technology Co Ltd CHSM72N-HC-585.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 556.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HA585AD-NGEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hansol Technics Co Ltd HA585AD-NGEA0 panels fit on a 600 V winter solar string?
At -10 C (14 F), Hansol Technics Co Ltd HA585AD-NGEA0 cold Voc rises from 51.2 V to 55.59 V (beta_Voc -0.245%/C), capping a 600 V string at 10 panels (555.9 V).
How much roof area does an 8 kW array of Hansol Technics Co Ltd HA585AD-NGEA0 need?
An 8 kW DC system uses 14 Hansol Technics Co Ltd HA585AD-NGEA0 modules (8,190 W STC / 7,791 W PTC), covering roughly 386 sq ft and saving ~$2,050/yr at 18.54 c/kWh.
How does Hansol Technics Co Ltd HA585AD-NGEA0 compare against Chint New Energy Technology Co Ltd CHSM72N-HC-585?
Hansol Technics Co Ltd HA585AD-NGEA0 outputs 585.0 W STC (51.2 V Voc, rank #1,751 of 21,677), while Chint New Energy Technology Co Ltd CHSM72N-HC-585 delivers 585.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)