Hansol Technics Co Ltd HA585-AD-NNEA0 is a 585.0 W STC (545.5 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.85% efficiency, 51.7 V Voc at 25 C, and 57.36 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 585.0 W
- PTC Wattage
- 545.5 W
- Voc @ 25C
- 51.7 V
- Efficiency
- 22.85%
How Does Hansol Technics Co Ltd HA585-AD-NNEA0 Compare Against Peer CEC Listings?
Engineering position of Hansol Technics Co Ltd HA585-AD-NNEA0 (585.0 W STC) vs. AE Solar GmbH AE585CMD-144BDS across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, Hansol Technics Co Ltd HA585-AD-NNEA0 pairs strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677) with 51.7 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,637 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer AE Solar GmbH AE585CMD-144BDS offers a 585.0 W alternative.
Where Does Hansol Technics Co Ltd HA585-AD-NNEA0 Fall Across Listed CEC Models?
Plots Hansol Technics Co Ltd HA585-AD-NNEA0 at 585.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HA585-AD-NNEA0?
Benchmarks Hansol Technics Co Ltd HA585-AD-NNEA0 on STC wattage, thermal PTC/STC retention, and 22.85 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA585-AD-NNEA0?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hansol Technics Co Ltd HA585-AD-NNEA0 by Hansol Technics Co Ltd.
Top 8.7% STC Output
585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.85% Aperture Efficiency
Power density 228.5 W/m2 (2.94 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 57.36 V at -10 C (573.6 V string) and 58.98 V at -20 C (10 max).
14 Panels = 8,190 W STC
Occupies 35.8 m2 (386 sq ft) producing 7,637 W PTC; NEC 690.8 OCPD floor is 22.48 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 51.7 * (1 + (-0.313/100) * (-10 - 25)) = 57.36 V | OCPD = 1.56 * 14.41 = 22.48 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA585-AD-NNEA0: Voc=51.7 V, beta_Voc=-0.313%/C, Isc=14.41 A, STC=585.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (573.6 V); 14 panels for 8 kW (386 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HA585-AD-NNEA0?
Laboratory test ratings recorded for Hansol Technics Co Ltd HA585-AD-NNEA0 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 545.5 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 51.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.41 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 43.0 V / 13.61 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.313 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.85% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HA585-AD-NNEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (386 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hansol Technics Co Ltd HA585-AD-NNEA0.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.43 kW | 303 sq ft | $1,609 | $2,721 |
| 8 kW Class | 14 | 8.19 kW | 386 sq ft | $2,050 | $3,466 |
| 10 kW Class | 18 | 10.53 kW | 496 sq ft | $2,636 | $4,457 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Sibling wattage bins and frame colors grouped with Hansol Technics Co Ltd HA585-AD-NNEA0 under Hansol Technics Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HA575AD-NNEA0 | 575.0 W | 546.7 W | 51.3 V | 42.6 V | 22.46% |
| Hansol Technics Co Ltd HA580AD-NNEA0 | 580.0 W | 551.6 W | 51.5 V | 42.8 V | 22.66% |
| Hansol Technics Co Ltd HA585-AD-NNEA0 | 585.0 W | 545.5 W | 51.7 V | 43.0 V | 22.85% |
| Hansol Technics Co Ltd HA590-AD-NNEA0 | 590.0 W | 550.3 W | 51.9 V | 43.2 V | 23.05% |
| Hansol Technics Co Ltd HA595-AD-NNEA0 | 595.0 W | 555.1 W | 52.1 V | 43.4 V | 23.24% |
How Many Hansol Technics Co Ltd HA585-AD-NNEA0 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Hansol Technics Co Ltd HA585-AD-NNEA0 (beta_Voc -0.313%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.98 V | 10 panels | 589.8 V | 16 panels |
| -10 C (14 F) | 57.36 V | 10 panels | 573.6 V | 17 panels |
| 0 C (32 F) | 55.75 V | 10 panels | 557.5 V | 17 panels |
| 25 C (77 F STC) | 51.7 V | 11 panels | 568.7 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA585-AD-NNEA0?
Closest cross-brand CEC competitors to Hansol Technics Co Ltd HA585-AD-NNEA0 matched near 585.0 W STC and 51.7 V Voc, led by AE Solar GmbH AE585CMD-144BDS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AE Solar GmbH AE585CMD-144BDS AE Solar GmbH |
585.0 W | Tie (0 W) | 51.6 V | 22.67% | 95.3% |
| DE SOLAR(S) PTE LTD DE585-144BG-182S-N/WW DE SOLAR(S) PTE LTD |
585.0 W | Tie (0 W) | 51.6 V | 22.67% | 95.3% |
| Chint New Energy Technology Co Ltd CHSM72N-HC-585 Chint New Energy Technology Co Ltd |
585.0 W | Tie (0 W) | 51.3 V | 22.67% | 94.7% |
| ELITE Solar ET-N772TBH585GB ELITE Solar |
585.0 W | Tie (0 W) | 52.28 V | 22.67% | 94.8% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA585-AD-NNEA0?
Evaluate Hansol Technics Co Ltd HA585-AD-NNEA0 (585.0 W STC, 51.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA585-AD-NNEA0 reaches 58.98 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA585-AD-NNEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HA585-AD-NNEA0 8 kW Residential Fit
Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AE Solar GmbH AE585CMD-144BDS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 545.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HA585-AD-NNEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HA585-AD-NNEA0?
Multiplying Hansol Technics Co Ltd HA585-AD-NNEA0's 14.41 A short-circuit current by 1.56 equals 22.48 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HA585-AD-NNEA0 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 57.36 V cold Voc at 14 F and handles 14.41 A Isc; string inverters cap Hansol Technics Co Ltd HA585-AD-NNEA0 at 10 panels on 600 V.
Is Hansol Technics Co Ltd HA585-AD-NNEA0 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HA585-AD-NNEA0 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)