Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HA585-AD-NNEA0 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HA585-AD-NNEA0 is a 585.0 W STC (545.5 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.85% efficiency, 51.7 V Voc at 25 C, and 57.36 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
585.0 W
PTC Wattage
545.5 W
Voc @ 25C
51.7 V
Efficiency
22.85%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HA585-AD-NNEA0 Compare Against Peer CEC Listings?

Engineering position of Hansol Technics Co Ltd HA585-AD-NNEA0 (585.0 W STC) vs. AE Solar GmbH AE585CMD-144BDS across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Hansol Technics Co Ltd HA585-AD-NNEA0 pairs strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677) with 51.7 V nominal Voc. An 8 kW residential build (8,190 W DC, 7,637 W PTC) saves ~$2,050/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer AE Solar GmbH AE585CMD-144BDS offers a 585.0 W alternative.

Where Does Hansol Technics Co Ltd HA585-AD-NNEA0 Fall Across Listed CEC Models?

Plots Hansol Technics Co Ltd HA585-AD-NNEA0 at 585.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HA585-AD-NNEA0 (585.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 585.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HA585-AD-NNEA0?

Benchmarks Hansol Technics Co Ltd HA585-AD-NNEA0 on STC wattage, thermal PTC/STC retention, and 22.85 aperture conversion efficiency against CEC peers.

Hansol Technics Co Ltd HA585-AD-NNEA0 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HA585-AD-NNEA0 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage585.0 WPTC/STC Retention93.2%Module Efficiency22.85%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA585-AD-NNEA0?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hansol Technics Co Ltd HA585-AD-NNEA0 by Hansol Technics Co Ltd.

Rank #1,751 / 21,677

Top 8.7% STC Output

585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,413

22.85% Aperture Efficiency

Power density 228.5 W/m2 (2.94 percentage points above 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.36 V at -10 C (573.6 V string) and 58.98 V at -20 C (10 max).

8 kW Reference Array

14 Panels = 8,190 W STC

Occupies 35.8 m2 (386 sq ft) producing 7,637 W PTC; NEC 690.8 OCPD floor is 22.48 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 51.7 * (1 + (-0.313/100) * (-10 - 25)) = 57.36 V | OCPD = 1.56 * 14.41 = 22.48 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA585-AD-NNEA0: Voc=51.7 V, beta_Voc=-0.313%/C, Isc=14.41 A, STC=585.0 W, Area=2.56 m2.

Result: 10 panels max on 600 V (573.6 V); 14 panels for 8 kW (386 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HA585-AD-NNEA0?

Laboratory test ratings recorded for Hansol Technics Co Ltd HA585-AD-NNEA0 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HA585-AD-NNEA0.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 585.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 545.5 W (93.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 51.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.41 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 43.0 V / 13.61 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.313 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.85% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HA585-AD-NNEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (386 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hansol Technics Co Ltd HA585-AD-NNEA0.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.43 kW 303 sq ft $1,609 $2,721
8 kW Class 14 8.19 kW 386 sq ft $2,050 $3,466
10 kW Class 18 10.53 kW 496 sq ft $2,636 $4,457

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Sibling wattage bins and frame colors grouped with Hansol Technics Co Ltd HA585-AD-NNEA0 under Hansol Technics Co Ltd to prevent duplicate spec pages.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HA585-AD-NNEA0 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HA575AD-NNEA0 575.0 W 546.7 W 51.3 V 42.6 V 22.46%
Hansol Technics Co Ltd HA580AD-NNEA0 580.0 W 551.6 W 51.5 V 42.8 V 22.66%
Hansol Technics Co Ltd HA585-AD-NNEA0 585.0 W 545.5 W 51.7 V 43.0 V 22.85%
Hansol Technics Co Ltd HA590-AD-NNEA0 590.0 W 550.3 W 51.9 V 43.2 V 23.05%
Hansol Technics Co Ltd HA595-AD-NNEA0 595.0 W 555.1 W 52.1 V 43.4 V 23.24%

How Many Hansol Technics Co Ltd HA585-AD-NNEA0 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Hansol Technics Co Ltd HA585-AD-NNEA0 (beta_Voc -0.313%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=51.7V and beta_Voc=-0.313%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 58.98 V 10 panels 589.8 V 16 panels
-10 C (14 F) 57.36 V 10 panels 573.6 V 17 panels
0 C (32 F) 55.75 V 10 panels 557.5 V 17 panels
25 C (77 F STC) 51.7 V 11 panels 568.7 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA585-AD-NNEA0?

Closest cross-brand CEC competitors to Hansol Technics Co Ltd HA585-AD-NNEA0 matched near 585.0 W STC and 51.7 V Voc, led by AE Solar GmbH AE585CMD-144BDS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AE Solar GmbH AE585CMD-144BDS
AE Solar GmbH
585.0 W Tie (0 W) 51.6 V 22.67% 95.3%
DE SOLAR(S) PTE LTD DE585-144BG-182S-N/WW
DE SOLAR(S) PTE LTD
585.0 W Tie (0 W) 51.6 V 22.67% 95.3%
Chint New Energy Technology Co Ltd CHSM72N-HC-585
Chint New Energy Technology Co Ltd
585.0 W Tie (0 W) 51.3 V 22.67% 94.7%
ELITE Solar ET-N772TBH585GB
ELITE Solar
585.0 W Tie (0 W) 52.28 V 22.67% 94.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA585-AD-NNEA0?

Evaluate Hansol Technics Co Ltd HA585-AD-NNEA0 (585.0 W STC, 51.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA585-AD-NNEA0 reaches 58.98 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 386 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA585-AD-NNEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HA585-AD-NNEA0 8 kW Residential Fit

Needs 14 modules (386 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AE Solar GmbH AE585CMD-144BDS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 545.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HA585-AD-NNEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HA585-AD-NNEA0?

Multiplying Hansol Technics Co Ltd HA585-AD-NNEA0's 14.41 A short-circuit current by 1.56 equals 22.48 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Hansol Technics Co Ltd HA585-AD-NNEA0 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 57.36 V cold Voc at 14 F and handles 14.41 A Isc; string inverters cap Hansol Technics Co Ltd HA585-AD-NNEA0 at 10 panels on 600 V.

Is Hansol Technics Co Ltd HA585-AD-NNEA0 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HA585-AD-NNEA0 rely on utility bill offset (~$2,050/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.