Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HA570AD-NGEA0 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HA570AD-NGEA0 is a 570.0 W STC (542.0 W PTC) Mono-c-Si solar module ranking #2,154 of 21,677 CEC listings (top 10.5%; higher than 89.5% of peers). It delivers 22.27% efficiency, 50.7 V Voc at 25 C, and 55.05 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
570.0 W
PTC Wattage
542.0 W
Voc @ 25C
50.7 V
Efficiency
22.27%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HA570AD-NGEA0 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HA570AD-NGEA0 (Mono-c-Si) residential solar systems.

Homeowners evaluating Hansol Technics Co Ltd HA570AD-NGEA0 need 11 panels for 6 kW or 15 panels (413 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.245%/C) pushes open-circuit voltage to 55.05 V at 14 F and 56.29 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Hansol Technics Co Ltd HA570AD-NGEA0 Fall Across Listed CEC Models?

Comparison of Hansol Technics Co Ltd HA570AD-NGEA0 (570.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HA570AD-NGEA0 (570.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 570.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HA570AD-NGEA0?

Relative ranking of Hansol Technics Co Ltd HA570AD-NGEA0 across nameplate watts, 95.1% PTC thermal ratio, and module aperture efficiency.

Hansol Technics Co Ltd HA570AD-NGEA0 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HA570AD-NGEA0 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage570.0 WPTC/STC Retention95.1%Module Efficiency22.27%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA570AD-NGEA0?

Summary of Hansol Technics Co Ltd HA570AD-NGEA0 output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,154 / 21,677

Top 10.5% STC Output

570.0 W STC (+185.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,523

22.27% Aperture Efficiency

Power density 222.7 W/m2 (2.36 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.05 V at -10 C (550.5 V string) and 56.29 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,550 W STC

Occupies 38.4 m2 (413 sq ft) producing 8,130 W PTC; NEC 690.8 OCPD floor is 22.32 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.7 * (1 + (-0.245/100) * (-10 - 25)) = 55.05 V | OCPD = 1.56 * 14.31 = 22.32 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA570AD-NGEA0: Voc=50.7 V, beta_Voc=-0.245%/C, Isc=14.31 A, STC=570.0 W, Area=2.56 m2.

Result: 10 panels max on 600 V (550.5 V); 15 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HA570AD-NGEA0?

Complete CEC test sheet for Hansol Technics Co Ltd HA570AD-NGEA0 including Isc (14.31 A), Voc (50.7 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HA570AD-NGEA0.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 570.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 542.0 W (95.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.31 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.1 V / 13.55 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.245 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.27% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HA570AD-NGEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HA570AD-NGEA0.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.27 kW 303 sq ft $1,569 $2,654
8 kW Class 15 8.55 kW 413 sq ft $2,140 $3,619
10 kW Class 18 10.26 kW 496 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Related Hansol Technics Co Ltd power steps and black/silver trims consolidated into this Hansol Technics Co Ltd HA570AD-NGEA0 series guide.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HA570AD-NGEA0 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HA565AD-NGEA0 565.0 W 537.1 W 50.6 V 41.9 V 22.07%
Hansol Technics Co Ltd HA570AD-NGEA0 570.0 W 542.0 W 50.7 V 42.1 V 22.27%

How Many Hansol Technics Co Ltd HA570AD-NGEA0 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hansol Technics Co Ltd HA570AD-NGEA0 (50.7 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=50.7V and beta_Voc=-0.245%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.29 V 10 panels 562.9 V 17 panels
-10 C (14 F) 55.05 V 10 panels 550.5 V 18 panels
0 C (32 F) 53.81 V 11 panels 591.9 V 18 panels
25 C (77 F STC) 50.7 V 11 panels 557.7 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA570AD-NGEA0?

Four comparable CEC modules such as Aptos Solar Technology LLC DNA-144-BFN10-570W-DG (570.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-144-BFN10-570W-DG
Aptos Solar Technology LLC
570.0 W Tie (0 W) 50.74 V 22.09% 94.9%
AE Solar GmbH AE570CMD-144BDS
AE Solar GmbH
570.0 W Tie (0 W) 51.2 V 22.09% 95.2%
DE SOLAR(S) PTE LTD DE570-144BG-182S-N/WW
DE SOLAR(S) PTE LTD
570.0 W Tie (0 W) 51.2 V 22.09% 95.2%
BYD Company Limited BYD565NLBK-36
BYD Company Limited
565.0 W -5.0 W 50.6 V 21.9% 94.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA570AD-NGEA0?

Evaluate Hansol Technics Co Ltd HA570AD-NGEA0 (570.0 W STC, 50.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA570AD-NGEA0 reaches 56.29 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA570AD-NGEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HA570AD-NGEA0 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,140/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-BFN10-570W-DG.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 542.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HA570AD-NGEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Hansol Technics Co Ltd HA570AD-NGEA0 PTC wattage (542.0 W) lower than STC (570.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 542.0 W PTC (95.1% retention) across Hansol Technics Co Ltd HA570AD-NGEA0's 2.56 m2 aperture.

Who should skip Hansol Technics Co Ltd HA570AD-NGEA0 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Hansol Technics Co Ltd HA570AD-NGEA0 panels (413 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-144-BFN10-570W-DG.

What is the 1,000 V commercial string limit for Hansol Technics Co Ltd HA570AD-NGEA0?

On 1,000 V commercial inverters at -10 C (55.05 V cold Voc), Hansol Technics Co Ltd HA570AD-NGEA0 fits up to 18 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.