Hansol Technics Co Ltd HA570-AD-NNEA0 is a 570.0 W STC (541.8 W PTC) Mono-c-Si solar module ranking #2,154 of 21,677 CEC listings (top 10.5%; higher than 89.5% of peers). It delivers 22.27% efficiency, 51.1 V Voc at 25 C, and 55.37 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 570.0 W
- PTC Wattage
- 541.8 W
- Voc @ 25C
- 51.1 V
- Efficiency
- 22.27%
How Does Hansol Technics Co Ltd HA570-AD-NNEA0 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HA570-AD-NNEA0 (Mono-c-Si) residential solar systems.
Hansol Technics Co Ltd HA570-AD-NNEA0 delivers 222.7 W/m2 (2.36 percentage points above 19.91% CEC median) and strong 95.1% PTC-to-STC heat retention (#713 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 56.6 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with AE Solar GmbH AE570CMD-144BDS (570.0 W).
Where Does Hansol Technics Co Ltd HA570-AD-NNEA0 Fall Across Listed CEC Models?
Comparison of Hansol Technics Co Ltd HA570-AD-NNEA0 (570.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Hansol Technics Co Ltd HA570-AD-NNEA0?
Relative ranking of Hansol Technics Co Ltd HA570-AD-NNEA0 across nameplate watts, 95.1% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA570-AD-NNEA0?
Summary of Hansol Technics Co Ltd HA570-AD-NNEA0 output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.
Top 10.5% STC Output
570.0 W STC (+185.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.27% Aperture Efficiency
Power density 222.7 W/m2 (2.36 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.37 V at -10 C (553.7 V string) and 56.6 V at -20 C (10 max).
15 Panels = 8,550 W STC
Occupies 38.4 m2 (413 sq ft) producing 8,127 W PTC; NEC 690.8 OCPD floor is 22.2 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 51.1 * (1 + (-0.239/100) * (-10 - 25)) = 55.37 V | OCPD = 1.56 * 14.23 = 22.2 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA570-AD-NNEA0: Voc=51.1 V, beta_Voc=-0.239%/C, Isc=14.23 A, STC=570.0 W, Area=2.56 m2.
Result: 10 panels max on 600 V (553.7 V); 15 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HA570-AD-NNEA0?
Complete CEC test sheet for Hansol Technics Co Ltd HA570-AD-NNEA0 including Isc (14.23 A), Voc (51.1 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 570.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 541.8 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 51.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.23 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.4 V / 13.45 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.239 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.27% (2.56 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HA570-AD-NNEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HA570-AD-NNEA0.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.27 kW | 303 sq ft | $1,569 | $2,654 |
| 8 kW Class | 15 | 8.55 kW | 413 sq ft | $2,140 | $3,619 |
| 10 kW Class | 18 | 10.26 kW | 496 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Related Hansol Technics Co Ltd power steps and black/silver trims consolidated into this Hansol Technics Co Ltd HA570-AD-NNEA0 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HA560AD-NNEA0 | 560.0 W | 532.1 W | 50.7 V | 42.0 V | 21.88% |
| Hansol Technics Co Ltd HA565AD-NNEA0 | 565.0 W | 537.0 W | 50.9 V | 42.2 V | 22.07% |
| Hansol Technics Co Ltd HA570-AD-NNEA0 | 570.0 W | 541.8 W | 51.1 V | 42.4 V | 22.27% |
| Hansol Technics Co Ltd HA570AD-NNEA0 | 570.0 W | 541.8 W | 51.1 V | 42.4 V | 22.27% |
How Many Hansol Technics Co Ltd HA570-AD-NNEA0 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Hansol Technics Co Ltd HA570-AD-NNEA0 (51.1 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.6 V | 10 panels | 566.0 V | 17 panels |
| -10 C (14 F) | 55.37 V | 10 panels | 553.7 V | 18 panels |
| 0 C (32 F) | 54.15 V | 11 panels | 595.6 V | 18 panels |
| 25 C (77 F STC) | 51.1 V | 11 panels | 562.1 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA570-AD-NNEA0?
Four comparable CEC modules such as AE Solar GmbH AE570CMD-144BDS (570.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AE Solar GmbH AE570CMD-144BDS AE Solar GmbH |
570.0 W | Tie (0 W) | 51.2 V | 22.09% | 95.2% |
| DE SOLAR(S) PTE LTD DE570-144BG-182S-N/WW DE SOLAR(S) PTE LTD |
570.0 W | Tie (0 W) | 51.2 V | 22.09% | 95.2% |
| Aptos Solar Technology LLC DNA-144-BFN10-570W-DG Aptos Solar Technology LLC |
570.0 W | Tie (0 W) | 50.74 V | 22.09% | 94.9% |
| AEG SOLAR ENERGY SRL ALPS72D30-570/TP AEG SOLAR ENERGY SRL |
570.0 W | Tie (0 W) | 52.1 V | 22.09% | 94.3% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA570-AD-NNEA0?
Evaluate Hansol Technics Co Ltd HA570-AD-NNEA0 (570.0 W STC, 51.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA570-AD-NNEA0 reaches 56.6 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA570-AD-NNEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HA570-AD-NNEA0 8 kW Residential Fit
Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,140/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AE Solar GmbH AE570CMD-144BDS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 541.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HA570-AD-NNEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hansol Technics Co Ltd HA570-AD-NNEA0 panels fit on a 600 V winter solar string?
At -10 C (14 F), Hansol Technics Co Ltd HA570-AD-NNEA0 cold Voc rises from 51.1 V to 55.37 V (beta_Voc -0.239%/C), capping a 600 V string at 10 panels (553.7 V).
How much roof area does an 8 kW array of Hansol Technics Co Ltd HA570-AD-NNEA0 need?
An 8 kW DC system uses 15 Hansol Technics Co Ltd HA570-AD-NNEA0 modules (8,550 W STC / 8,127 W PTC), covering roughly 413 sq ft and saving ~$2,140/yr at 18.54 c/kWh.
How does Hansol Technics Co Ltd HA570-AD-NNEA0 compare against AE Solar GmbH AE570CMD-144BDS?
Hansol Technics Co Ltd HA570-AD-NNEA0 outputs 570.0 W STC (51.1 V Voc, rank #2,154 of 21,677), while AE Solar GmbH AE570CMD-144BDS delivers 570.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)