Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HA420AA-DGEA0 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HA420AA-DGEA0 is a 420.0 W STC (399.1 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 21.65% efficiency, 38.1 V Voc at 25 C, and 41.37 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
420.0 W
PTC Wattage
399.1 W
Voc @ 25C
38.1 V
Efficiency
21.65%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HA420AA-DGEA0 Compare Against Peer CEC Listings?

Solar engineering breakdown for Hansol Technics Co Ltd HA420AA-DGEA0: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Hansol Technics Co Ltd and peers, Hansol Technics Co Ltd HA420AA-DGEA0 stands 10.0 W above the 410.0 W Mono-c-Si median and strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677). Sizing 6 kW (15 panels) to 10 kW (24 panels) yields $1,577-$2,523/yr in baseline US bill offset. Lower 38.1 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does Hansol Technics Co Ltd HA420AA-DGEA0 Fall Across Listed CEC Models?

Distribution marker showing Hansol Technics Co Ltd HA420AA-DGEA0 (420.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HA420AA-DGEA0 (420.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 420.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HA420AA-DGEA0?

Dataset percentiles tracking Hansol Technics Co Ltd HA420AA-DGEA0 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Hansol Technics Co Ltd HA420AA-DGEA0 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HA420AA-DGEA0 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage420.0 WPTC/STC Retention95.0%Module Efficiency21.65%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA420AA-DGEA0?

Benchmark highlights for Hansol Technics Co Ltd HA420AA-DGEA0 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #7,910 / 21,677

Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,009

21.65% Aperture Efficiency

Power density 216.5 W/m2 (1.74 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.37 V at -10 C (579.2 V string) and 42.3 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,400 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,982 W PTC; NEC 690.8 OCPD floor is 21.95 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.1 * (1 + (-0.245/100) * (-10 - 25)) = 41.37 V | OCPD = 1.56 * 14.07 = 21.95 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA420AA-DGEA0: Voc=38.1 V, beta_Voc=-0.245%/C, Isc=14.07 A, STC=420.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (579.2 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HA420AA-DGEA0?

Official CEC datasheet figures for Hansol Technics Co Ltd HA420AA-DGEA0 (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HA420AA-DGEA0.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 420.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 399.1 W (95.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.07 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.5 V / 13.33 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.245 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.65% (1.94 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HA420AA-DGEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hansol Technics Co Ltd HA420AA-DGEA0 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.3 kW 313 sq ft $1,577 $2,666
8 kW Class 20 8.4 kW 418 sq ft $2,102 $3,555
10 kW Class 24 10.08 kW 501 sq ft $2,523 $4,266

How Many Hansol Technics Co Ltd HA420AA-DGEA0 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HA420AA-DGEA0 (41.37 V at 14 F).

Computed from Voc=38.1V and beta_Voc=-0.245%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.3 V 14 panels 592.2 V 23 panels
-10 C (14 F) 41.37 V 14 panels 579.2 V 24 panels
0 C (32 F) 40.43 V 14 panels 566.0 V 24 panels
25 C (77 F STC) 38.1 V 15 panels 571.5 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA420AA-DGEA0?

Competing CEC solar panels closest to Hansol Technics Co Ltd HA420AA-DGEA0 in nameplate wattage and Voc, starting with Auxin Solar AXN10M420W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN10M420W
Auxin Solar
420.0 W Tie (0 W) 38.26 V 21.65% 93.2%
Aptos Solar Technology LLC DNA-108-MFN10-420W
Aptos Solar Technology LLC
420.0 W Tie (0 W) 38.5 V 21.65% 95.0%
Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-420
Elin Energy (Sirius PV)
420.0 W Tie (0 W) 38.5 V 21.65% 94.9%
Elin Energy (Sirius PV) ELNSM54M-HC-N-420
Elin Energy (Sirius PV)
420.0 W Tie (0 W) 38.5 V 21.65% 94.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA420AA-DGEA0?

Evaluate Hansol Technics Co Ltd HA420AA-DGEA0 (420.0 W STC, 38.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA420AA-DGEA0 reaches 42.3 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA420AA-DGEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HA420AA-DGEA0 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Auxin Solar AXN10M420W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 399.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HA420AA-DGEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HA420AA-DGEA0?

Multiplying Hansol Technics Co Ltd HA420AA-DGEA0's 14.07 A short-circuit current by 1.56 equals 21.95 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can Hansol Technics Co Ltd HA420AA-DGEA0 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.37 V cold Voc at 14 F and handles 14.07 A Isc; string inverters cap Hansol Technics Co Ltd HA420AA-DGEA0 at 14 panels on 600 V.

Is Hansol Technics Co Ltd HA420AA-DGEA0 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HA420AA-DGEA0 rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.