Hansol Technics Co Ltd HA420AA-DGEA0 is a 420.0 W STC (399.1 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 21.65% efficiency, 38.1 V Voc at 25 C, and 41.37 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 420.0 W
- PTC Wattage
- 399.1 W
- Voc @ 25C
- 38.1 V
- Efficiency
- 21.65%
How Does Hansol Technics Co Ltd HA420AA-DGEA0 Compare Against Peer CEC Listings?
Solar engineering breakdown for Hansol Technics Co Ltd HA420AA-DGEA0: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Hansol Technics Co Ltd and peers, Hansol Technics Co Ltd HA420AA-DGEA0 stands 10.0 W above the 410.0 W Mono-c-Si median and strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677). Sizing 6 kW (15 panels) to 10 kW (24 panels) yields $1,577-$2,523/yr in baseline US bill offset. Lower 38.1 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Hansol Technics Co Ltd HA420AA-DGEA0 Fall Across Listed CEC Models?
Distribution marker showing Hansol Technics Co Ltd HA420AA-DGEA0 (420.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hansol Technics Co Ltd HA420AA-DGEA0?
Dataset percentiles tracking Hansol Technics Co Ltd HA420AA-DGEA0 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA420AA-DGEA0?
Benchmark highlights for Hansol Technics Co Ltd HA420AA-DGEA0 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 37.8% STC Output
420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.65% Aperture Efficiency
Power density 216.5 W/m2 (1.74 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.37 V at -10 C (579.2 V string) and 42.3 V at -20 C (14 max).
20 Panels = 8,400 W STC
Occupies 38.8 m2 (418 sq ft) producing 7,982 W PTC; NEC 690.8 OCPD floor is 21.95 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.1 * (1 + (-0.245/100) * (-10 - 25)) = 41.37 V | OCPD = 1.56 * 14.07 = 21.95 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA420AA-DGEA0: Voc=38.1 V, beta_Voc=-0.245%/C, Isc=14.07 A, STC=420.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (579.2 V); 20 panels for 8 kW (418 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HA420AA-DGEA0?
Official CEC datasheet figures for Hansol Technics Co Ltd HA420AA-DGEA0 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 399.1 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.07 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.5 V / 13.33 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.245 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.65% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HA420AA-DGEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hansol Technics Co Ltd HA420AA-DGEA0 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.3 kW | 313 sq ft | $1,577 | $2,666 |
| 8 kW Class | 20 | 8.4 kW | 418 sq ft | $2,102 | $3,555 |
| 10 kW Class | 24 | 10.08 kW | 501 sq ft | $2,523 | $4,266 |
How Many Hansol Technics Co Ltd HA420AA-DGEA0 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HA420AA-DGEA0 (41.37 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.3 V | 14 panels | 592.2 V | 23 panels |
| -10 C (14 F) | 41.37 V | 14 panels | 579.2 V | 24 panels |
| 0 C (32 F) | 40.43 V | 14 panels | 566.0 V | 24 panels |
| 25 C (77 F STC) | 38.1 V | 15 panels | 571.5 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA420AA-DGEA0?
Competing CEC solar panels closest to Hansol Technics Co Ltd HA420AA-DGEA0 in nameplate wattage and Voc, starting with Auxin Solar AXN10M420W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN10M420W Auxin Solar |
420.0 W | Tie (0 W) | 38.26 V | 21.65% | 93.2% |
| Aptos Solar Technology LLC DNA-108-MFN10-420W Aptos Solar Technology LLC |
420.0 W | Tie (0 W) | 38.5 V | 21.65% | 95.0% |
| Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-420 Elin Energy (Sirius PV) |
420.0 W | Tie (0 W) | 38.5 V | 21.65% | 94.9% |
| Elin Energy (Sirius PV) ELNSM54M-HC-N-420 Elin Energy (Sirius PV) |
420.0 W | Tie (0 W) | 38.5 V | 21.65% | 94.9% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA420AA-DGEA0?
Evaluate Hansol Technics Co Ltd HA420AA-DGEA0 (420.0 W STC, 38.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA420AA-DGEA0 reaches 42.3 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA420AA-DGEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HA420AA-DGEA0 8 kW Residential Fit
Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Auxin Solar AXN10M420W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 399.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HA420AA-DGEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HA420AA-DGEA0?
Multiplying Hansol Technics Co Ltd HA420AA-DGEA0's 14.07 A short-circuit current by 1.56 equals 21.95 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HA420AA-DGEA0 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 41.37 V cold Voc at 14 F and handles 14.07 A Isc; string inverters cap Hansol Technics Co Ltd HA420AA-DGEA0 at 14 panels on 600 V.
Is Hansol Technics Co Ltd HA420AA-DGEA0 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HA420AA-DGEA0 rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)