Hanersun Energy Co Ltd HN21RN-66HT610W is a 610.0 W STC (580.0 W PTC) Mono-c-Si solar module ranking #1,104 of 21,677 CEC listings (top 5.6%; higher than 94.4% of peers). It delivers 23.19% efficiency, 48.72 V Voc at 25 C, and 53.39 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 610.0 W
- PTC Wattage
- 580.0 W
- Voc @ 25C
- 48.72 V
- Efficiency
- 23.19%
How Does Hanersun Energy Co Ltd HN21RN-66HT610W Compare Against Peer CEC Listings?
Engineering position of Hanersun Energy Co Ltd HN21RN-66HT610W (610.0 W STC) vs. ELITE Solar ET-NR66TBH610GB across 5,889 CEC Mono-c-Si solar modules.
Built with 66 Mono-c-Si cells, Hanersun Energy Co Ltd HN21RN-66HT610W pairs strong 95.1% PTC-to-STC heat retention (#713 of 21,677) with 48.72 V nominal Voc. An 8 kW residential build (8,540 W DC, 8,120 W PTC) saves ~$2,137/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer ELITE Solar ET-NR66TBH610GB offers a 610.0 W alternative.
Where Does Hanersun Energy Co Ltd HN21RN-66HT610W Fall Across Listed CEC Models?
Plots Hanersun Energy Co Ltd HN21RN-66HT610W at 610.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Hanersun Energy Co Ltd HN21RN-66HT610W?
Benchmarks Hanersun Energy Co Ltd HN21RN-66HT610W on STC wattage, thermal PTC/STC retention, and 23.19 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN21RN-66HT610W?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hanersun Energy Co Ltd HN21RN-66HT610W by Hanersun Energy Co Ltd.
Top 5.6% STC Output
610.0 W STC (+225.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.19% Aperture Efficiency
Power density 231.9 W/m2 (3.28 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.39 V at -10 C (587.3 V string) and 54.73 V at -20 C (10 max).
14 Panels = 8,540 W STC
Occupies 36.8 m2 (396 sq ft) producing 8,120 W PTC; NEC 690.8 OCPD floor is 24.87 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.72 * (1 + (-0.274/100) * (-10 - 25)) = 53.39 V | OCPD = 1.56 * 15.94 = 24.87 A
Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN21RN-66HT610W: Voc=48.72 V, beta_Voc=-0.274%/C, Isc=15.94 A, STC=610.0 W, Area=2.63 m2.
Result: 11 panels max on 600 V (587.3 V); 14 panels for 8 kW (396 sq ft).
What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN21RN-66HT610W?
Laboratory test ratings recorded for Hanersun Energy Co Ltd HN21RN-66HT610W (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 610.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 580.0 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.72 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 15.94 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.59 V / 15.03 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.274 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.19% (2.63 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hanersun Energy Co Ltd HN21RN-66HT610W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (396 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hanersun Energy Co Ltd HN21RN-66HT610W.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.1 kW | 283 sq ft | $1,527 | $2,582 |
| 8 kW Class | 14 | 8.54 kW | 396 sq ft | $2,137 | $3,614 |
| 10 kW Class | 17 | 10.37 kW | 481 sq ft | $2,596 | $4,389 |
Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?
Sibling wattage bins and frame colors grouped with Hanersun Energy Co Ltd HN21RN-66HT610W under Hanersun Energy Co Ltd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hanersun Energy Co Ltd HN21RN-66HT600W | 600.0 W | 570.3 W | 48.32 V | 40.23 V | 22.81% |
| Hanersun Energy Co Ltd HN21RN-66HT605W | 605.0 W | 575.2 W | 48.52 V | 40.41 V | 23.0% |
| Hanersun Energy Co Ltd HN21RN-66HT610W | 610.0 W | 580.0 W | 48.72 V | 40.59 V | 23.19% |
| Hanersun Energy Co Ltd HN21RN-66HT615W | 615.0 W | 584.9 W | 48.92 V | 40.77 V | 23.38% |
| Hanersun Energy Co Ltd HN21RN-66HT620W | 620.0 W | 589.8 W | 49.12 V | 40.95 V | 23.57% |
How Many Hanersun Energy Co Ltd HN21RN-66HT610W Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Hanersun Energy Co Ltd HN21RN-66HT610W (beta_Voc -0.274%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.73 V | 10 panels | 547.3 V | 18 panels |
| -10 C (14 F) | 53.39 V | 11 panels | 587.3 V | 18 panels |
| 0 C (32 F) | 52.06 V | 11 panels | 572.7 V | 19 panels |
| 25 C (77 F STC) | 48.72 V | 12 panels | 584.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN21RN-66HT610W?
Closest cross-brand CEC competitors to Hanersun Energy Co Ltd HN21RN-66HT610W matched near 610.0 W STC and 48.72 V Voc, led by ELITE Solar ET-NR66TBH610GB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| ELITE Solar ET-NR66TBH610GB ELITE Solar |
610.0 W | Tie (0 W) | 48.7 V | 22.59% | 95.0% |
| ELITE Solar ET-NR66TBH610GL ELITE Solar |
610.0 W | Tie (0 W) | 48.7 V | 22.59% | 95.0% |
| Hengdian Group DMEGC Magnetics Co Ltd DM610G12RT-B66yyy Hengdian Group DMEGC Magnetics Co Ltd |
610.0 W | Tie (0 W) | 48.7 V | 22.59% | 94.0% |
| Chint New Energy Technology Co Ltd CHSM66RN(DG)/F-BH-610 Chint New Energy Technology Co Ltd |
610.0 W | Tie (0 W) | 48.74 V | 22.59% | 95.4% |
What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN21RN-66HT610W?
Evaluate Hanersun Energy Co Ltd HN21RN-66HT610W (610.0 W STC, 48.72 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN21RN-66HT610W reaches 54.73 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 396 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN21RN-66HT610W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanersun Energy Co Ltd HN21RN-66HT610W 8 kW Residential Fit
Needs 14 modules (396 sq ft) with a 25 A string OCPD, offsetting ~$2,137/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare ELITE Solar ET-NR66TBH610GB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 580.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanersun Energy Co Ltd HN21RN-66HT610W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hanersun Energy Co Ltd HN21RN-66HT610W?
Multiplying Hanersun Energy Co Ltd HN21RN-66HT610W's 15.94 A short-circuit current by 1.56 equals 24.87 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Hanersun Energy Co Ltd HN21RN-66HT610W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.39 V cold Voc at 14 F and handles 15.94 A Isc; string inverters cap Hanersun Energy Co Ltd HN21RN-66HT610W at 11 panels on 600 V.
Is Hanersun Energy Co Ltd HN21RN-66HT610W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanersun Energy Co Ltd HN21RN-66HT610W rely on utility bill offset (~$2,137/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)