Skip to main content
WireAndSun
Calculators
CEC PV Module

Hanersun Energy Co Ltd HN18N-54HT435W — CEC Solar Module Specifications

Manufacturer: Hanersun Energy Co Ltd Registry: CEC Verified Engineering Specification

Hanersun Energy Co Ltd HN18N-54HT435W is a 435.0 W STC (412.9 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 22.89% efficiency, 38.5 V Voc at 25 C, and 41.65 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
412.9 W
Voc @ 25C
38.5 V
Efficiency
22.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanersun Energy Co Ltd HN18N-54HT435W Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hanersun Energy Co Ltd HN18N-54HT435W (Mono-c-Si) residential solar systems.

Homeowners evaluating Hanersun Energy Co Ltd HN18N-54HT435W need 14 panels for 6 kW or 19 panels (389 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (389 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.234%/C) pushes open-circuit voltage to 41.65 V at 14 F and 42.55 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Hanersun Energy Co Ltd HN18N-54HT435W Fall Across Listed CEC Models?

Comparison of Hanersun Energy Co Ltd HN18N-54HT435W (435.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanersun Energy Co Ltd HN18N-54HT435W (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanersun Energy Co: 435.0 W

What Dataset Percentiles Define Hanersun Energy Co Ltd HN18N-54HT435W?

Relative ranking of Hanersun Energy Co Ltd HN18N-54HT435W across nameplate watts, 94.9% PTC thermal ratio, and module aperture efficiency.

Hanersun Energy Co Ltd HN18N-54HT435W Engineering BenchmarksPercentile comparison of Hanersun Energy Co Ltd HN18N-54HT435W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention94.9%Module Efficiency22.89%

What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN18N-54HT435W?

Summary of Hanersun Energy Co Ltd HN18N-54HT435W output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,307

22.89% Aperture Efficiency

Power density 228.9 W/m2 (2.98 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.65 V at -10 C (583.1 V string) and 42.55 V at -20 C (14 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 36.1 m2 (389 sq ft) producing 7,845 W PTC; NEC 690.8 OCPD floor is 22.14 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 38.5 * (1 + (-0.234/100) * (-10 - 25)) = 41.65 V | OCPD = 1.56 * 14.19 = 22.14 A

Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN18N-54HT435W: Voc=38.5 V, beta_Voc=-0.234%/C, Isc=14.19 A, STC=435.0 W, Area=1.9 m2.

Result: 14 panels max on 600 V (583.1 V); 19 panels for 8 kW (389 sq ft).

What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN18N-54HT435W?

Complete CEC test sheet for Hanersun Energy Co Ltd HN18N-54HT435W including Isc (14.19 A), Voc (38.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hanersun Energy Co Ltd HN18N-54HT435W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 412.9 W (94.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 38.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.19 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.5 V / 13.39 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.234 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.89% (1.9 m2) Array roof footprint density
Cell Count & Technology 54 cells (Mono-c-Si) Monofacial backsheet

How Many Hanersun Energy Co Ltd HN18N-54HT435W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hanersun Energy Co Ltd HN18N-54HT435W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 286 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 389 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 470 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?

Related Hanersun Energy Co Ltd power steps and black/silver trims consolidated into this Hanersun Energy Co Ltd HN18N-54HT435W series guide.

Sibling CEC listings grouped into the Hanersun Energy Co Ltd HN18N-54HT435W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanersun Energy Co Ltd HN18N-54HT425W 425.0 W 403.2 W 38.1 V 32.1 V 22.37%
Hanersun Energy Co Ltd HN18N-54HT430W 430.0 W 408.1 W 38.3 V 32.3 V 22.63%
Hanersun Energy Co Ltd HN18N-54HT435W 435.0 W 412.9 W 38.5 V 32.5 V 22.89%
Hanersun Energy Co Ltd HN18N-54HT440W 440.0 W 417.8 W 38.7 V 32.7 V 23.16%
Hanersun Energy Co Ltd HN18N-54HT445W 445.0 W 422.6 W 38.9 V 32.9 V 23.42%

How Many Hanersun Energy Co Ltd HN18N-54HT435W Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hanersun Energy Co Ltd HN18N-54HT435W (38.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=38.5V and beta_Voc=-0.234%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.55 V 14 panels 595.7 V 23 panels
-10 C (14 F) 41.65 V 14 panels 583.1 V 24 panels
0 C (32 F) 40.75 V 14 panels 570.5 V 24 panels
25 C (77 F STC) 38.5 V 15 panels 577.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN18N-54HT435W?

Four comparable CEC modules such as AXITEC AC-435TGB/108BB (435.0 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-435TGB/108BB
AXITEC
435.0 W Tie (0 W) 38.43 V 22.89% 95.0%
Auxin Solar AXN10M435B
Auxin Solar
435.0 W Tie (0 W) 38.66 V 22.42% 93.2%
Auxin Solar AXN10M435W
Auxin Solar
435.0 W Tie (0 W) 38.66 V 22.42% 93.3%
Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-435
Elin Energy (Sirius PV)
435.0 W Tie (0 W) 39.1 V 22.42% 95.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN18N-54HT435W?

Evaluate Hanersun Energy Co Ltd HN18N-54HT435W (435.0 W STC, 38.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN18N-54HT435W reaches 42.55 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 389 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (389 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN18N-54HT435W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanersun Energy Co Ltd HN18N-54HT435W 8 kW Residential Fit

Needs 19 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare AXITEC AC-435TGB/108BB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanersun Energy Co Ltd HN18N-54HT435W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Hanersun Energy Co Ltd HN18N-54HT435W PTC wattage (412.9 W) lower than STC (435.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 412.9 W PTC (94.9% retention) across Hanersun Energy Co Ltd HN18N-54HT435W's 1.9 m2 aperture.

Who should skip Hanersun Energy Co Ltd HN18N-54HT435W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 Hanersun Energy Co Ltd HN18N-54HT435W panels (389 sq ft) leave unusable roof gaps vs. AXITEC AC-435TGB/108BB.

What is the 1,000 V commercial string limit for Hanersun Energy Co Ltd HN18N-54HT435W?

On 1,000 V commercial inverters at -10 C (41.65 V cold Voc), Hanersun Energy Co Ltd HN18N-54HT435W fits up to 24 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.