Gintung Energy GTEC-310G6S is a 310.0 W STC (271.8 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.85% efficiency, 45.22 V Voc at 25 C, and 50.65 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 271.8 W
- Voc @ 25C
- 45.22 V
- Efficiency
- 15.85%
How Does Gintung Energy GTEC-310G6S Compare Against Peer CEC Listings?
Engineering position of Gintung Energy GTEC-310G6S (310.0 W STC) vs. Advance Power API-P310 across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, Gintung Energy GTEC-310G6S pairs typical 87.7% PTC-to-STC thermal output (271.8 W real-world rating) with 45.22 V nominal Voc. An 8 kW residential build (8,060 W DC, 7,067 W PTC) saves ~$2,017/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Advance Power API-P310 offers a 310.0 W alternative.
Where Does Gintung Energy GTEC-310G6S Fall Across Listed CEC Models?
Plots Gintung Energy GTEC-310G6S at 310.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Gintung Energy GTEC-310G6S?
Benchmarks Gintung Energy GTEC-310G6S on STC wattage, thermal PTC/STC retention, and 15.85 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Gintung Energy GTEC-310G6S?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Gintung Energy GTEC-310G6S by Gintung Energy.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.85% Aperture Efficiency
Power density 158.5 W/m2 (4.06 percentage points below 19.91% CEC median). PTC/STC ratio: 87.7% (rank #21,496).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.65 V at -10 C (557.1 V string) and 52.2 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 50.9 m2 (547 sq ft) producing 7,067 W PTC; NEC 690.8 OCPD floor is 14.16 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.22 * (1 + (-0.343/100) * (-10 - 25)) = 50.65 V | OCPD = 1.56 * 9.08 = 14.16 A
Inputs from CEC Modules.csv for Gintung Energy GTEC-310G6S: Voc=45.22 V, beta_Voc=-0.343%/C, Isc=9.08 A, STC=310.0 W, Area=1.956 m2.
Result: 11 panels max on 600 V (557.1 V); 26 panels for 8 kW (547 sq ft).
What Are the Published CEC Specifications for Gintung Energy GTEC-310G6S?
Laboratory test ratings recorded for Gintung Energy GTEC-310G6S (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 271.8 W (87.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.22 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.08 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.71 V / 8.68 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.343 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.85% (1.956 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Gintung Energy GTEC-310G6S Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (547 sq ft at 8 kW), and estimated Year-1 electric bill offset for Gintung Energy GTEC-310G6S.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 421 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 547 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 695 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?
Sibling wattage bins and frame colors grouped with Gintung Energy GTEC-310G6S under Gintung Energy to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Gintung Energy GTEC-300G6S | 300.0 W | 262.8 W | 45.07 V | 35.46 V | 15.34% |
| Gintung Energy GTEC-305G6S | 305.0 W | 267.3 W | 45.18 V | 35.55 V | 15.59% |
| Gintung Energy GTEC-310G6S | 310.0 W | 271.8 W | 45.22 V | 35.71 V | 15.85% |
| Gintung Energy GTEC-315G6S | 315.0 W | 276.4 W | 45.27 V | 35.84 V | 16.1% |
| Gintung Energy GTEC-320G6S | 320.0 W | 280.9 W | 45.31 V | 35.91 V | 16.36% |
How Many Gintung Energy GTEC-310G6S Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Gintung Energy GTEC-310G6S (beta_Voc -0.343%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.2 V | 11 panels | 574.2 V | 19 panels |
| -10 C (14 F) | 50.65 V | 11 panels | 557.1 V | 19 panels |
| 0 C (32 F) | 49.1 V | 12 panels | 589.2 V | 20 panels |
| 25 C (77 F STC) | 45.22 V | 13 panels | 587.9 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Gintung Energy GTEC-310G6S?
Closest cross-brand CEC competitors to Gintung Energy GTEC-310G6S matched near 310.0 W STC and 45.22 V Voc, led by Advance Power API-P310.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-P310 Advance Power |
310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| Auxin Solar AXN6P612T310 Auxin Solar |
310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| Centrosolar America DP72 310 Centrosolar America |
310.0 W | Tie (0 W) | 45.18 V | 15.94% | 90.2% |
| AXITEC AC-310P/156-72S AXITEC |
310.0 W | Tie (0 W) | 45.05 V | 16.01% | 89.0% |
What Are the Design Limits and Best-Fit Uses for Gintung Energy GTEC-310G6S?
Evaluate Gintung Energy GTEC-310G6S (310.0 W STC, 45.22 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy GTEC-310G6S reaches 52.2 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 547 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (547 sq ft).
- 2026 tax credit baseline: cash residential installs of Gintung Energy GTEC-310G6S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Gintung Energy GTEC-310G6S 8 kW Residential Fit
Needs 26 modules (547 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 271.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Gintung Energy GTEC-310G6S by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Gintung Energy GTEC-310G6S?
Multiplying Gintung Energy GTEC-310G6S's 9.08 A short-circuit current by 1.56 equals 14.16 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Gintung Energy GTEC-310G6S pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.65 V cold Voc at 14 F and handles 9.08 A Isc; string inverters cap Gintung Energy GTEC-310G6S at 11 panels on 600 V.
Is Gintung Energy GTEC-310G6S eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Gintung Energy GTEC-310G6S rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)