Skip to main content
WireAndSun
Calculators
CEC PV Module

Gintung Energy ASEC-310G6S — CEC Solar Module Specifications

Manufacturer: Gintung Energy Registry: CEC Verified Engineering Specification

Gintung Energy ASEC-310G6S is a 310.0 W STC (271.8 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.85% efficiency, 45.22 V Voc at 25 C, and 50.65 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
271.8 W
Voc @ 25C
45.22 V
Efficiency
15.85%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Gintung Energy ASEC-310G6S Compare Against Peer CEC Listings?

How Gintung Energy Gintung Energy ASEC-310G6S handles rooftop heat (271.8 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Gintung Energy ASEC-310G6S exhibits 9.08 A short-circuit current, requiring a 14.16 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #15,760 of 21,677 (100.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 50.9 m2 for an 8 kW system (33 panels for 10 kW). Mid-range 45.22 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Gintung Energy ASEC-310G6S Fall Across Listed CEC Models?

Where Gintung Energy ASEC-310G6S (310.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Gintung Energy ASEC-310G6S (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGintung Energy ASE: 310.0 W

What Dataset Percentiles Define Gintung Energy ASEC-310G6S?

Percentile placement of Gintung Energy ASEC-310G6S across power density (158.5 W/m2), thermal retention, and nameplate STC wattage.

Gintung Energy ASEC-310G6S Engineering BenchmarksPercentile comparison of Gintung Energy ASEC-310G6S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention87.7%Module Efficiency15.85%

What Do the Dataset Ranks Show for Gintung Energy ASEC-310G6S?

Four critical engineering numbers homeowners and solar installers check first when reviewing Gintung Energy ASEC-310G6S specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,395

15.85% Aperture Efficiency

Power density 158.5 W/m2 (4.06 percentage points below 19.91% CEC median). PTC/STC ratio: 87.7% (rank #21,496).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.65 V at -10 C (557.1 V string) and 52.2 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 50.9 m2 (547 sq ft) producing 7,067 W PTC; NEC 690.8 OCPD floor is 14.16 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.22 * (1 + (-0.343/100) * (-10 - 25)) = 50.65 V | OCPD = 1.56 * 9.08 = 14.16 A

Inputs from CEC Modules.csv for Gintung Energy ASEC-310G6S: Voc=45.22 V, beta_Voc=-0.343%/C, Isc=9.08 A, STC=310.0 W, Area=1.956 m2.

Result: 11 panels max on 600 V (557.1 V); 26 panels for 8 kW (547 sq ft).

What Are the Published CEC Specifications for Gintung Energy ASEC-310G6S?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Gintung Energy ASEC-310G6S.

Official California Energy Commission (NREL SAM) test parameters for Gintung Energy ASEC-310G6S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 271.8 W (87.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.22 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.08 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 35.71 V / 8.68 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.343 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.85% (1.956 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Gintung Energy ASEC-310G6S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Gintung Energy ASEC-310G6S (310.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 421 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 547 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 695 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Gintung Energy Series?

All closely matched Gintung Energy wattages and cosmetic trims sharing the Gintung Energy ASEC-310G6S architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Gintung Energy ASEC-310G6S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Gintung Energy ASEC-300G6S 300.0 W 262.8 W 45.07 V 35.46 V 15.34%
Gintung Energy ASEC-305G6S 305.0 W 267.3 W 45.18 V 35.55 V 15.59%
Gintung Energy ASEC-310G6S 310.0 W 271.8 W 45.22 V 35.71 V 15.85%
Gintung Energy ASEC-315G6S 315.0 W 276.4 W 45.27 V 35.84 V 16.1%
Gintung Energy ASEC-320G6S 320.0 W 280.9 W 45.31 V 35.91 V 16.36%

How Many Gintung Energy ASEC-310G6S Modules Fit in a Cold-Weather String?

Maximum series module counts for Gintung Energy ASEC-310G6S from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.22V and beta_Voc=-0.343%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.2 V 11 panels 574.2 V 19 panels
-10 C (14 F) 50.65 V 11 panels 557.1 V 19 panels
0 C (32 F) 49.1 V 12 panels 589.2 V 20 panels
25 C (77 F STC) 45.22 V 13 panels 587.9 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Gintung Energy ASEC-310G6S?

Alternative CEC solar modules from competing brands near Gintung Energy ASEC-310G6S (310.0 W), including Advance Power API-P310. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-P310
Advance Power
310.0 W Tie (0 W) 45.22 V 15.89% 89.5%
Auxin Solar AXN6P612T310
Auxin Solar
310.0 W Tie (0 W) 45.22 V 15.89% 89.5%
Centrosolar America DP72 310
Centrosolar America
310.0 W Tie (0 W) 45.18 V 15.94% 90.2%
AXITEC AC-310P/156-72S
AXITEC
310.0 W Tie (0 W) 45.05 V 16.01% 89.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Gintung Energy ASEC-310G6S?

Evaluate Gintung Energy ASEC-310G6S (310.0 W STC, 45.22 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Gintung Energy ASEC-310G6S reaches 52.2 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 547 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (547 sq ft).
  • 2026 tax credit baseline: cash residential installs of Gintung Energy ASEC-310G6S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Gintung Energy ASEC-310G6S 8 kW Residential Fit

Needs 26 modules (547 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P310.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 271.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Gintung Energy ASEC-310G6S by Gintung Energy grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Gintung Energy ASEC-310G6S PTC wattage (271.8 W) lower than STC (310.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 271.8 W PTC (87.7% retention) across Gintung Energy ASEC-310G6S's 1.956 m2 aperture.

Who should skip Gintung Energy ASEC-310G6S on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 26 Gintung Energy ASEC-310G6S panels (547 sq ft) leave unusable roof gaps vs. Advance Power API-P310.

What is the 1,000 V commercial string limit for Gintung Energy ASEC-310G6S?

On 1,000 V commercial inverters at -10 C (50.65 V cold Voc), Gintung Energy ASEC-310G6S fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Gintung Energy ASEC-310G6S.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.