First Solar Inc FS-6485A-P is a 485.0 W STC (457.1 W PTC) CdTe solar module ranking #4,730 of 21,677 CEC listings (top 22.2%; higher than 77.8% of peers). It delivers 19.25% efficiency, 225.9 V Voc at 25 C, and 247.8 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 485.0 W
- PTC Wattage
- 457.1 W
- Voc @ 25C
- 225.9 V
- Efficiency
- 19.25%
How Does First Solar Inc FS-6485A-P Compare Against Peer CEC Listings?
How First Solar Inc First Solar Inc FS-6485A-P handles rooftop heat (457.1 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, First Solar Inc FS-6485A-P exhibits 2.62 A short-circuit current, requiring a 4.09 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #4,730 of 21,677 (40.0 W above the 445.0 W CdTe median), this modern high-density residential and light-commercial module covers 42.8 m2 for an 8 kW system (21 panels for 10 kW). Higher 225.9 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).
Where Does First Solar Inc FS-6485A-P Fall Across Listed CEC Models?
Where First Solar Inc FS-6485A-P (485.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-6485A-P?
Percentile placement of First Solar Inc FS-6485A-P across power density (192.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for First Solar Inc FS-6485A-P?
Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-6485A-P specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
Top 22.2% STC Output
485.0 W STC (+100.0 W vs all-CEC median) vs 445.0 W CdTe median.
19.25% Aperture Efficiency
Power density 192.5 W/m2 (0.66 percentage points below 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 247.8 V at -10 C (495.6 V string) and 254.06 V at -20 C (2 max).
17 Panels = 8,245 W STC
Occupies 42.8 m2 (461 sq ft) producing 7,771 W PTC; NEC 690.8 OCPD floor is 4.09 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 225.9 * (1 + (-0.277/100) * (-10 - 25)) = 247.8 V | OCPD = 1.56 * 2.62 = 4.09 A
Inputs from CEC Modules.csv for First Solar Inc FS-6485A-P: Voc=225.9 V, beta_Voc=-0.277%/C, Isc=2.62 A, STC=485.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (495.6 V); 17 panels for 8 kW (461 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6485A-P?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-6485A-P.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 485.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 457.1 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 225.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.62 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 194.0 V / 2.5 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.277 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.25% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 268 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6485A-P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-6485A-P (485.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.3 kW | 353 sq ft | $1,577 | $2,666 |
| 8 kW Class | 17 | 8.24 kW | 461 sq ft | $2,062 | $3,487 |
| 10 kW Class | 21 | 10.19 kW | 570 sq ft | $2,550 | $4,313 |
How Many First Solar Inc FS-6485A-P Modules Fit in a Cold-Weather String?
Maximum series module counts for First Solar Inc FS-6485A-P from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 254.06 V | 2 panels | 508.1 V | 3 panels |
| -10 C (14 F) | 247.8 V | 2 panels | 495.6 V | 4 panels |
| 0 C (32 F) | 241.54 V | 2 panels | 483.1 V | 4 panels |
| 25 C (77 F STC) | 225.9 V | 2 panels | 451.8 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6485A-P?
Alternative CEC solar modules from competing brands near First Solar Inc FS-6485A-P (485.0 W), including Applied Materials Full Size Tandem Junction.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Tandem Junction Applied Materials |
458.0 W | -27.0 W | 280.0 V | 8.01% | 91.7% |
| Heliene 96M475 Heliene |
475.0 W | -10.0 W | 62.39 V | 18.85% | 90.5% |
| Heliene 96M460 Heliene |
460.0 W | -25.0 W | 61.79 V | 18.25% | 90.4% |
| CSI Solar Co Ltd CS3Y-485MS CSI Solar Co Ltd |
485.0 W | Tie (0 W) | 53.1 V | 21.18% | 93.6% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6485A-P?
Evaluate First Solar Inc FS-6485A-P (485.0 W STC, 225.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6485A-P reaches 254.06 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 461 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (461 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6485A-P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6485A-P 8 kW Residential Fit
Needs 17 modules (461 sq ft) with a 15 A string OCPD, offsetting ~$2,062/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Tandem Junction.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 457.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6485A-P by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is First Solar Inc FS-6485A-P PTC wattage (457.1 W) lower than STC (485.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 457.1 W PTC (94.2% retention) across First Solar Inc FS-6485A-P's 2.52 m2 aperture.
Who should skip First Solar Inc FS-6485A-P on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 17 First Solar Inc FS-6485A-P panels (461 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Tandem Junction.
What is the 1,000 V commercial string limit for First Solar Inc FS-6485A-P?
On 1,000 V commercial inverters at -10 C (247.8 V cold Voc), First Solar Inc FS-6485A-P fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6485A-P.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)