First Solar Inc FS-6440 is a 440.0 W STC (414.2 W PTC) CdTe solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 17.78% efficiency, 220.0 V Voc at 25 C, and 241.1 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 414.2 W
- Voc @ 25C
- 220.0 V
- Efficiency
- 17.78%
How Does First Solar Inc FS-6440 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-6440 (CdTe) residential solar systems.
First Solar Inc FS-6440 delivers 177.8 W/m2 (2.13 percentage points below 19.91% CEC median) and strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 19 panels (506 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 247.13 V per unit, capping 600 V circuits at 2 panels. Compare specs directly with Applied Materials Full Size Single Junction Version 10 (414.0 W).
Where Does First Solar Inc FS-6440 Fall Across Listed CEC Models?
Comparison of First Solar Inc FS-6440 (440.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define First Solar Inc FS-6440?
Relative ranking of First Solar Inc FS-6440 across nameplate watts, 94.1% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for First Solar Inc FS-6440?
Summary of First Solar Inc FS-6440 output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 445.0 W CdTe median.
17.78% Aperture Efficiency
Power density 177.8 W/m2 (2.13 percentage points below 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 241.1 V at -10 C (482.2 V string) and 247.13 V at -20 C (2 max).
19 Panels = 8,360 W STC
Occupies 47.0 m2 (506 sq ft) producing 7,870 W PTC; NEC 690.8 OCPD floor is 3.98 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 220.0 * (1 + (-0.274/100) * (-10 - 25)) = 241.1 V | OCPD = 1.56 * 2.55 = 3.98 A
Inputs from CEC Modules.csv for First Solar Inc FS-6440: Voc=220.0 V, beta_Voc=-0.274%/C, Isc=2.55 A, STC=440.0 W, Area=2.475 m2.
Result: 2 panels max on 600 V (482.2 V); 19 panels for 8 kW (506 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6440?
Complete CEC test sheet for First Solar Inc FS-6440 including Isc (2.55 A), Voc (220.0 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 414.2 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 220.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 184.7 V / 2.38 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.274 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.78% (2.475 m2) | Array roof footprint density |
| Cell Count & Technology | 264 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6440 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-6440.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 373 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 506 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 613 sq ft | $2,533 | $4,283 |
How Many First Solar Inc FS-6440 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for First Solar Inc FS-6440 (220.0 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 247.13 V | 2 panels | 494.3 V | 4 panels |
| -10 C (14 F) | 241.1 V | 2 panels | 482.2 V | 4 panels |
| 0 C (32 F) | 235.07 V | 2 panels | 470.1 V | 4 panels |
| 25 C (77 F STC) | 220.0 V | 2 panels | 440.0 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6440?
Four comparable CEC modules such as Applied Materials Full Size Single Junction Version 10 (414.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Single Junction Version 10 Applied Materials |
414.0 W | -26.0 W | 194.2 V | 7.24% | 92.9% |
| CSI Solar Co Ltd CS3Y-445P CSI Solar Co Ltd |
445.0 W | +5.0 W | 51.4 V | 19.43% | 93.0% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
440.0 W | Tie (0 W) | 49.6 V | 20.75% | 92.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
440.0 W | Tie (0 W) | 49.3 V | 20.56% | 92.6% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6440?
Evaluate First Solar Inc FS-6440 (440.0 W STC, 220.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6440 reaches 247.13 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 506 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (506 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6440 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6440 8 kW Residential Fit
Needs 19 modules (506 sq ft) with a 15 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 414.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6440 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-6440 panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-6440 cold Voc rises from 220.0 V to 241.1 V (beta_Voc -0.274%/C), capping a 600 V string at 2 panels (482.2 V).
How much roof area does an 8 kW array of First Solar Inc FS-6440 need?
An 8 kW DC system uses 19 First Solar Inc FS-6440 modules (8,360 W STC / 7,870 W PTC), covering roughly 506 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does First Solar Inc FS-6440 compare against Applied Materials Full Size Single Junction Version 10?
First Solar Inc FS-6440 outputs 440.0 W STC (220.0 V Voc, rank #6,418 of 21,677), while Applied Materials Full Size Single Junction Version 10 delivers 414.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)