First Solar Inc FS-6440-P is a 440.0 W STC (412.3 W PTC) CdTe solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 17.46% efficiency, 220.0 V Voc at 25 C, and 240.87 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 412.3 W
- Voc @ 25C
- 220.0 V
- Efficiency
- 17.46%
How Does First Solar Inc FS-6440-P Compare Against Peer CEC Listings?
Solar engineering breakdown for First Solar Inc FS-6440-P: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 440.0 W STC and 412.3 W PTC, First Solar Inc FS-6440-P sits +55.0 W vs all-CEC median (top 31.6%; higher than 68.4% of peers) among 21,677 listed modules. Power density reaches 174.6 W/m2 (2.45 percentage points below 19.91% CEC median). Higher 220.0 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 4 panels in series. Alternative peer Applied Materials Full Size Single Junction Version 10 rates 414.0 W.
Where Does First Solar Inc FS-6440-P Fall Across Listed CEC Models?
Distribution marker showing First Solar Inc FS-6440-P (440.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define First Solar Inc FS-6440-P?
Dataset percentiles tracking First Solar Inc FS-6440-P power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for First Solar Inc FS-6440-P?
Benchmark highlights for First Solar Inc FS-6440-P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 445.0 W CdTe median.
17.46% Aperture Efficiency
Power density 174.6 W/m2 (2.45 percentage points below 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 240.87 V at -10 C (481.7 V string) and 246.83 V at -20 C (2 max).
19 Panels = 8,360 W STC
Occupies 47.9 m2 (515 sq ft) producing 7,834 W PTC; NEC 690.8 OCPD floor is 3.99 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 220.0 * (1 + (-0.271/100) * (-10 - 25)) = 240.87 V | OCPD = 1.56 * 2.56 = 3.99 A
Inputs from CEC Modules.csv for First Solar Inc FS-6440-P: Voc=220.0 V, beta_Voc=-0.271%/C, Isc=2.56 A, STC=440.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (481.7 V); 19 panels for 8 kW (515 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6440-P?
Official CEC datasheet figures for First Solar Inc FS-6440-P (CdTe) used in utility interconnection and permit reviews. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 412.3 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 220.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 184.7 V / 2.38 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.46% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 264 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6440-P Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many First Solar Inc FS-6440-P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 380 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 515 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 624 sq ft | $2,533 | $4,283 |
How Many First Solar Inc FS-6440-P Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6440-P (240.87 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 246.83 V | 2 panels | 493.7 V | 4 panels |
| -10 C (14 F) | 240.87 V | 2 panels | 481.7 V | 4 panels |
| 0 C (32 F) | 234.91 V | 2 panels | 469.8 V | 4 panels |
| 25 C (77 F STC) | 220.0 V | 2 panels | 440.0 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6440-P?
Competing CEC solar panels closest to First Solar Inc FS-6440-P in nameplate wattage and Voc, starting with Applied Materials Full Size Single Junction Version 10.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Single Junction Version 10 Applied Materials |
414.0 W | -26.0 W | 194.2 V | 7.24% | 92.9% |
| CSI Solar Co Ltd CS3Y-445P CSI Solar Co Ltd |
445.0 W | +5.0 W | 51.4 V | 19.43% | 93.0% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
440.0 W | Tie (0 W) | 49.6 V | 20.75% | 92.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
440.0 W | Tie (0 W) | 49.3 V | 20.56% | 92.6% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6440-P?
Evaluate First Solar Inc FS-6440-P (440.0 W STC, 220.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6440-P reaches 246.83 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 515 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (515 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6440-P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6440-P 8 kW Residential Fit
Needs 19 modules (515 sq ft) with a 15 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6440-P by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-6440-P panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-6440-P cold Voc rises from 220.0 V to 240.87 V (beta_Voc -0.271%/C), capping a 600 V string at 2 panels (481.7 V).
How much roof area does an 8 kW array of First Solar Inc FS-6440-P need?
An 8 kW DC system uses 19 First Solar Inc FS-6440-P modules (8,360 W STC / 7,834 W PTC), covering roughly 515 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does First Solar Inc FS-6440-P compare against Applied Materials Full Size Single Junction Version 10?
First Solar Inc FS-6440-P outputs 440.0 W STC (220.0 V Voc, rank #6,418 of 21,677), while Applied Materials Full Size Single Junction Version 10 delivers 414.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)