First Solar Inc FS-6415A is a 415.0 W STC (389.5 W PTC) CdTe solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 16.73% efficiency, 218.1 V Voc at 25 C, and 239.24 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 415.0 W
- PTC Wattage
- 389.5 W
- Voc @ 25C
- 218.1 V
- Efficiency
- 16.73%
How Does First Solar Inc FS-6415A Compare Against Peer CEC Listings?
How First Solar Inc First Solar Inc FS-6415A handles rooftop heat (389.5 W PTC), 8 kW sizing, and cold winter string voltage.
First Solar Inc builds the First Solar Inc FS-6415A (CdTe) as a modern high-density residential and light-commercial module delivering 167.3 W/m2 (3.18 percentage points below 19.91% CEC median). Compared against Applied Materials Full Size Single Junction Version 10 (414.0 W), this model holds strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677). Higher 218.1 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), while NEC 690.8 sets a 3.95 A overcurrent floor served by a 15 A breaker.
Where Does First Solar Inc FS-6415A Fall Across Listed CEC Models?
Where First Solar Inc FS-6415A (415.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-6415A?
Percentile placement of First Solar Inc FS-6415A across power density (167.3 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for First Solar Inc FS-6415A?
Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-6415A specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Top 39.4% STC Output
415.0 W STC (+30.0 W vs all-CEC median) vs 445.0 W CdTe median.
16.73% Aperture Efficiency
Power density 167.3 W/m2 (3.18 percentage points below 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 239.24 V at -10 C (478.5 V string) and 245.29 V at -20 C (2 max).
20 Panels = 8,300 W STC
Occupies 49.6 m2 (534 sq ft) producing 7,790 W PTC; NEC 690.8 OCPD floor is 3.95 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 218.1 * (1 + (-0.277/100) * (-10 - 25)) = 239.24 V | OCPD = 1.56 * 2.53 = 3.95 A
Inputs from CEC Modules.csv for First Solar Inc FS-6415A: Voc=218.1 V, beta_Voc=-0.277%/C, Isc=2.53 A, STC=415.0 W, Area=2.48 m2.
Result: 2 panels max on 600 V (478.5 V); 20 panels for 8 kW (534 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6415A?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-6415A.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 389.5 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 218.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.53 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 179.3 V / 2.31 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.277 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.73% (2.48 m2) | Array roof footprint density |
| Cell Count & Technology | 264 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6415A Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-6415A (415.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.22 kW | 400 sq ft | $1,557 | $2,632 |
| 8 kW Class | 20 | 8.3 kW | 534 sq ft | $2,077 | $3,513 |
| 10 kW Class | 25 | 10.38 kW | 667 sq ft | $2,598 | $4,393 |
How Many First Solar Inc FS-6415A Modules Fit in a Cold-Weather String?
Maximum series module counts for First Solar Inc FS-6415A from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 245.29 V | 2 panels | 490.6 V | 4 panels |
| -10 C (14 F) | 239.24 V | 2 panels | 478.5 V | 4 panels |
| 0 C (32 F) | 233.2 V | 2 panels | 466.4 V | 4 panels |
| 25 C (77 F STC) | 218.1 V | 2 panels | 436.2 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6415A?
Alternative CEC solar modules from competing brands near First Solar Inc FS-6415A (415.0 W), including Applied Materials Full Size Single Junction Version 10.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Single Junction Version 10 Applied Materials |
414.0 W | -1.0 W | 194.2 V | 7.24% | 92.9% |
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | -5.0 W | 52.7 V | 21.03% | 94.1% |
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | -5.0 W | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | -5.0 W | 49.47 V | 20.92% | 93.3% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6415A?
Evaluate First Solar Inc FS-6415A (415.0 W STC, 218.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6415A reaches 245.29 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 534 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (534 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6415A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6415A 8 kW Residential Fit
Needs 20 modules (534 sq ft) with a 15 A string OCPD, offsetting ~$2,077/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 389.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6415A by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for First Solar Inc FS-6415A?
Multiplying First Solar Inc FS-6415A's 2.53 A short-circuit current by 1.56 equals 3.95 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can First Solar Inc FS-6415A pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 239.24 V cold Voc at 14 F and handles 2.53 A Isc; string inverters cap First Solar Inc FS-6415A at 2 panels on 600 V.
Is First Solar Inc FS-6415A eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of First Solar Inc FS-6415A rely on utility bill offset (~$2,077/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)