First Solar Inc FS-6415-P is a 415.0 W STC (388.5 W PTC) CdTe solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 16.47% efficiency, 218.1 V Voc at 25 C, and 238.79 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 415.0 W
- PTC Wattage
- 388.5 W
- Voc @ 25C
- 218.1 V
- Efficiency
- 16.47%
How Does First Solar Inc FS-6415-P Compare Against Peer CEC Listings?
How First Solar Inc First Solar Inc FS-6415-P handles rooftop heat (388.5 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, First Solar Inc FS-6415-P exhibits 2.53 A short-circuit current, requiring a 3.95 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #8,199 of 21,677 (30.0 W below the 445.0 W CdTe median), this modern high-density residential and light-commercial module covers 50.4 m2 for an 8 kW system (25 panels for 10 kW). Higher 218.1 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C).
Where Does First Solar Inc FS-6415-P Fall Across Listed CEC Models?
Where First Solar Inc FS-6415-P (415.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define First Solar Inc FS-6415-P?
Percentile placement of First Solar Inc FS-6415-P across power density (164.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for First Solar Inc FS-6415-P?
Four critical engineering numbers homeowners and solar installers check first when reviewing First Solar Inc FS-6415-P specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Top 39.4% STC Output
415.0 W STC (+30.0 W vs all-CEC median) vs 445.0 W CdTe median.
16.47% Aperture Efficiency
Power density 164.7 W/m2 (3.44 percentage points below 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 238.79 V at -10 C (477.6 V string) and 244.7 V at -20 C (2 max).
20 Panels = 8,300 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,770 W PTC; NEC 690.8 OCPD floor is 3.95 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 218.1 * (1 + (-0.271/100) * (-10 - 25)) = 238.79 V | OCPD = 1.56 * 2.53 = 3.95 A
Inputs from CEC Modules.csv for First Solar Inc FS-6415-P: Voc=218.1 V, beta_Voc=-0.271%/C, Isc=2.53 A, STC=415.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (477.6 V); 20 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6415-P?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for First Solar Inc FS-6415-P.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 388.5 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 218.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.53 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 179.3 V / 2.31 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.47% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 264 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6415-P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using First Solar Inc FS-6415-P (415.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.22 kW | 407 sq ft | $1,557 | $2,632 |
| 8 kW Class | 20 | 8.3 kW | 543 sq ft | $2,077 | $3,513 |
| 10 kW Class | 25 | 10.38 kW | 678 sq ft | $2,598 | $4,393 |
How Many First Solar Inc FS-6415-P Modules Fit in a Cold-Weather String?
Maximum series module counts for First Solar Inc FS-6415-P from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 244.7 V | 2 panels | 489.4 V | 4 panels |
| -10 C (14 F) | 238.79 V | 2 panels | 477.6 V | 4 panels |
| 0 C (32 F) | 232.88 V | 2 panels | 465.8 V | 4 panels |
| 25 C (77 F STC) | 218.1 V | 2 panels | 436.2 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6415-P?
Alternative CEC solar modules from competing brands near First Solar Inc FS-6415-P (415.0 W), including Applied Materials Full Size Single Junction Version 10.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Single Junction Version 10 Applied Materials |
414.0 W | -1.0 W | 194.2 V | 7.24% | 92.9% |
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | -5.0 W | 52.7 V | 21.03% | 94.1% |
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | -5.0 W | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | -5.0 W | 49.47 V | 20.92% | 93.3% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6415-P?
Evaluate First Solar Inc FS-6415-P (415.0 W STC, 218.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6415-P reaches 244.7 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 543 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (543 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6415-P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6415-P 8 kW Residential Fit
Needs 20 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,077/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 388.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6415-P by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is First Solar Inc FS-6415-P PTC wattage (388.5 W) lower than STC (415.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 388.5 W PTC (93.6% retention) across First Solar Inc FS-6415-P's 2.52 m2 aperture.
Who should skip First Solar Inc FS-6415-P on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 First Solar Inc FS-6415-P panels (543 sq ft) leave unusable roof gaps vs. Applied Materials Full Size Single Junction Version 10.
What is the 1,000 V commercial string limit for First Solar Inc FS-6415-P?
On 1,000 V commercial inverters at -10 C (238.79 V cold Voc), First Solar Inc FS-6415-P fits up to 4 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-6415-P.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)