First Solar Inc FS-6415-P-I is a 415.0 W STC (388.5 W PTC) CdTe solar module ranking #8,199 of 21,677 CEC listings (top 39.4%; higher than 60.6% of peers). It delivers 16.47% efficiency, 218.1 V Voc at 25 C, and 238.79 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 415.0 W
- PTC Wattage
- 388.5 W
- Voc @ 25C
- 218.1 V
- Efficiency
- 16.47%
How Does First Solar Inc FS-6415-P-I Compare Against Peer CEC Listings?
Solar engineering breakdown for First Solar Inc FS-6415-P-I: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 415.0 W STC and 388.5 W PTC, First Solar Inc FS-6415-P-I sits +30.0 W vs all-CEC median (top 39.4%; higher than 60.6% of peers) among 21,677 listed modules. Power density reaches 164.7 W/m2 (3.44 percentage points below 19.91% CEC median). Higher 218.1 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 4 panels in series. Alternative peer Applied Materials Full Size Single Junction Version 10 rates 414.0 W.
Where Does First Solar Inc FS-6415-P-I Fall Across Listed CEC Models?
Distribution marker showing First Solar Inc FS-6415-P-I (415.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define First Solar Inc FS-6415-P-I?
Dataset percentiles tracking First Solar Inc FS-6415-P-I power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for First Solar Inc FS-6415-P-I?
Benchmark highlights for First Solar Inc FS-6415-P-I covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 39.4% STC Output
415.0 W STC (+30.0 W vs all-CEC median) vs 445.0 W CdTe median.
16.47% Aperture Efficiency
Power density 164.7 W/m2 (3.44 percentage points below 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 238.79 V at -10 C (477.6 V string) and 244.7 V at -20 C (2 max).
20 Panels = 8,300 W STC
Occupies 50.4 m2 (543 sq ft) producing 7,770 W PTC; NEC 690.8 OCPD floor is 3.95 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 218.1 * (1 + (-0.271/100) * (-10 - 25)) = 238.79 V | OCPD = 1.56 * 2.53 = 3.95 A
Inputs from CEC Modules.csv for First Solar Inc FS-6415-P-I: Voc=218.1 V, beta_Voc=-0.271%/C, Isc=2.53 A, STC=415.0 W, Area=2.52 m2.
Result: 2 panels max on 600 V (477.6 V); 20 panels for 8 kW (543 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6415-P-I?
Official CEC datasheet figures for First Solar Inc FS-6415-P-I (CdTe) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 415.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 388.5 W (93.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 218.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.53 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 179.3 V / 2.31 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.271 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.47% (2.52 m2) | Array roof footprint density |
| Cell Count & Technology | 264 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6415-P-I Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many First Solar Inc FS-6415-P-I modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.22 kW | 407 sq ft | $1,557 | $2,632 |
| 8 kW Class | 20 | 8.3 kW | 543 sq ft | $2,077 | $3,513 |
| 10 kW Class | 25 | 10.38 kW | 678 sq ft | $2,598 | $4,393 |
How Many First Solar Inc FS-6415-P-I Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6415-P-I (238.79 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 244.7 V | 2 panels | 489.4 V | 4 panels |
| -10 C (14 F) | 238.79 V | 2 panels | 477.6 V | 4 panels |
| 0 C (32 F) | 232.88 V | 2 panels | 465.8 V | 4 panels |
| 25 C (77 F STC) | 218.1 V | 2 panels | 436.2 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6415-P-I?
Competing CEC solar panels closest to First Solar Inc FS-6415-P-I in nameplate wattage and Voc, starting with Applied Materials Full Size Single Junction Version 10.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Single Junction Version 10 Applied Materials |
414.0 W | -1.0 W | 194.2 V | 7.24% | 92.9% |
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | -5.0 W | 52.7 V | 21.03% | 94.1% |
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | -5.0 W | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | -5.0 W | 49.47 V | 20.92% | 93.3% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6415-P-I?
Evaluate First Solar Inc FS-6415-P-I (415.0 W STC, 218.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6415-P-I reaches 244.7 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 543 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (543 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6415-P-I carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6415-P-I 8 kW Residential Fit
Needs 20 modules (543 sq ft) with a 15 A string OCPD, offsetting ~$2,077/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 388.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6415-P-I by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-6415-P-I panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-6415-P-I cold Voc rises from 218.1 V to 238.79 V (beta_Voc -0.271%/C), capping a 600 V string at 2 panels (477.6 V).
How much roof area does an 8 kW array of First Solar Inc FS-6415-P-I need?
An 8 kW DC system uses 20 First Solar Inc FS-6415-P-I modules (8,300 W STC / 7,770 W PTC), covering roughly 543 sq ft and saving ~$2,077/yr at 18.54 c/kWh.
How does First Solar Inc FS-6415-P-I compare against Applied Materials Full Size Single Junction Version 10?
First Solar Inc FS-6415-P-I outputs 415.0 W STC (218.1 V Voc, rank #8,199 of 21,677), while Applied Materials Full Size Single Junction Version 10 delivers 414.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)