First Solar Inc FS-6410 is a 410.0 W STC (382.2 W PTC) CdTe solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 16.53% efficiency, 217.4 V Voc at 25 C, and 238.63 V cold Voc at -10 C (2 panels max per 600 V string).
- STC Wattage
- 410.0 W
- PTC Wattage
- 382.2 W
- Voc @ 25C
- 217.4 V
- Efficiency
- 16.53%
How Does First Solar Inc FS-6410 Compare Against Peer CEC Listings?
Solar engineering breakdown for First Solar Inc FS-6410: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 410.0 W STC and 382.2 W PTC, First Solar Inc FS-6410 sits +25.0 W vs all-CEC median (top 41.3%; higher than 58.7% of peers) among 21,677 listed modules. Power density reaches 165.3 W/m2 (3.38 percentage points below 19.91% CEC median). Higher 217.4 V open-circuit voltage caps 600 V residential strings at 2 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 4 panels in series. Alternative peer Applied Materials Full Size Single Junction Version 10 rates 414.0 W.
Where Does First Solar Inc FS-6410 Fall Across Listed CEC Models?
Distribution marker showing First Solar Inc FS-6410 (410.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define First Solar Inc FS-6410?
Dataset percentiles tracking First Solar Inc FS-6410 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for First Solar Inc FS-6410?
Benchmark highlights for First Solar Inc FS-6410 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 41.3% STC Output
410.0 W STC (+25.0 W vs all-CEC median) vs 445.0 W CdTe median.
16.53% Aperture Efficiency
Power density 165.3 W/m2 (3.38 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
2 Panels Max @ -10 C (600 V)
Cold Voc reaches 238.63 V at -10 C (477.3 V string) and 244.69 V at -20 C (2 max).
20 Panels = 8,200 W STC
Occupies 49.6 m2 (534 sq ft) producing 7,644 W PTC; NEC 690.8 OCPD floor is 3.93 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 217.4 * (1 + (-0.279/100) * (-10 - 25)) = 238.63 V | OCPD = 1.56 * 2.52 = 3.93 A
Inputs from CEC Modules.csv for First Solar Inc FS-6410: Voc=217.4 V, beta_Voc=-0.279%/C, Isc=2.52 A, STC=410.0 W, Area=2.48 m2.
Result: 2 panels max on 600 V (477.3 V); 20 panels for 8 kW (534 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-6410?
Official CEC datasheet figures for First Solar Inc FS-6410 (CdTe) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 410.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 382.2 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 217.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 2.52 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 178.3 V / 2.3 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.279 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.53% (2.48 m2) | Array roof footprint density |
| Cell Count & Technology | 264 cells (CdTe) | Monofacial backsheet |
How Many First Solar Inc FS-6410 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many First Solar Inc FS-6410 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.15 kW | 400 sq ft | $1,539 | $2,603 |
| 8 kW Class | 20 | 8.2 kW | 534 sq ft | $2,052 | $3,470 |
| 10 kW Class | 25 | 10.25 kW | 667 sq ft | $2,565 | $4,338 |
How Many First Solar Inc FS-6410 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on First Solar Inc FS-6410 (238.63 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 244.69 V | 2 panels | 489.4 V | 4 panels |
| -10 C (14 F) | 238.63 V | 2 panels | 477.3 V | 4 panels |
| 0 C (32 F) | 232.56 V | 2 panels | 465.1 V | 4 panels |
| 25 C (77 F STC) | 217.4 V | 2 panels | 434.8 V | 4 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-6410?
Competing CEC solar panels closest to First Solar Inc FS-6410 in nameplate wattage and Voc, starting with Applied Materials Full Size Single Junction Version 10.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Applied Materials Full Size Single Junction Version 10 Applied Materials |
414.0 W | +4.0 W | 194.2 V | 7.24% | 92.9% |
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | Tie (0 W) | 52.7 V | 21.03% | 94.1% |
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | Tie (0 W) | 49.47 V | 20.92% | 93.3% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-6410?
Evaluate First Solar Inc FS-6410 (410.0 W STC, 217.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-6410 reaches 244.69 V per panel—exceeding 2 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 534 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (534 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-6410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-6410 8 kW Residential Fit
Needs 20 modules (534 sq ft) with a 15 A string OCPD, offsetting ~$2,052/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 2 panels (-10 C) or 2 panels (-20 C), or compare Applied Materials Full Size Single Junction Version 10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 382.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-6410 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many First Solar Inc FS-6410 panels fit on a 600 V winter solar string?
At -10 C (14 F), First Solar Inc FS-6410 cold Voc rises from 217.4 V to 238.63 V (beta_Voc -0.279%/C), capping a 600 V string at 2 panels (477.3 V).
How much roof area does an 8 kW array of First Solar Inc FS-6410 need?
An 8 kW DC system uses 20 First Solar Inc FS-6410 modules (8,200 W STC / 7,644 W PTC), covering roughly 534 sq ft and saving ~$2,052/yr at 18.54 c/kWh.
How does First Solar Inc FS-6410 compare against Applied Materials Full Size Single Junction Version 10?
First Solar Inc FS-6410 outputs 410.0 W STC (217.4 V Voc, rank #8,539 of 21,677), while Applied Materials Full Size Single Junction Version 10 delivers 414.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)