First Solar Inc FS-370 is a 70.0 W STC (66.4 W PTC) Thin Film solar module ranking #21,637 of 21,677 CEC listings (below all-CEC median; higher than 0.2% of peers). It delivers 9.72% efficiency, 60.6 V Voc at 25 C, and 64.23 V cold Voc at -10 C (9 panels max per 600 V string).
- STC Wattage
- 70.0 W
- PTC Wattage
- 66.4 W
- Voc @ 25C
- 60.6 V
- Efficiency
- 9.72%
How Does First Solar Inc FS-370 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for First Solar Inc FS-370 (Thin Film) residential solar systems.
Homeowners evaluating First Solar Inc FS-370 need 86 panels for 6 kW or 115 panels (891 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 115 panels (891 sq ft). Under NEC 690.7(A), beta_Voc (-0.171%/C) pushes open-circuit voltage to 64.23 V at 14 F and 65.26 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does First Solar Inc FS-370 Fall Across Listed CEC Models?
Comparison of First Solar Inc FS-370 (70.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define First Solar Inc FS-370?
Relative ranking of First Solar Inc FS-370 across nameplate watts, 94.9% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for First Solar Inc FS-370?
Summary of First Solar Inc FS-370 output rank, 8 kW array size (115 panels), efficiency rating, and 600 V string limit.
70.0 W STC · Higher Than 0.2%
70.0 W STC (-315.0 W vs all-CEC median) vs 117.5 W Thin Film median.
9.72% Aperture Efficiency
Power density 97.2 W/m2 (10.19 percentage points below 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).
9 Panels Max @ -10 C (600 V)
Cold Voc reaches 64.23 V at -10 C (578.1 V string) and 65.26 V at -20 C (9 max).
115 Panels = 8,050 W STC
Occupies 82.8 m2 (891 sq ft) producing 7,636 W PTC; NEC 690.8 OCPD floor is 2.71 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 60.6 * (1 + (-0.171/100) * (-10 - 25)) = 64.23 V | OCPD = 1.56 * 1.74 = 2.71 A
Inputs from CEC Modules.csv for First Solar Inc FS-370: Voc=60.6 V, beta_Voc=-0.171%/C, Isc=1.74 A, STC=70.0 W, Area=0.72 m2.
Result: 9 panels max on 600 V (578.1 V); 115 panels for 8 kW (891 sq ft).
What Are the Published CEC Specifications for First Solar Inc FS-370?
Complete CEC test sheet for First Solar Inc FS-370 including Isc (1.74 A), Voc (60.6 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 70.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 66.4 W (94.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 60.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 1.74 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 48.1 V / 1.46 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.171 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 9.72% (0.72 m2) | Array roof footprint density |
| Cell Count & Technology | 77 cells (Thin Film) | Monofacial backsheet |
How Many First Solar Inc FS-370 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using First Solar Inc FS-370.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 86 | 6.02 kW | 667 sq ft | $1,507 | $2,548 |
| 8 kW Class | 115 | 8.05 kW | 891 sq ft | $2,015 | $3,407 |
| 10 kW Class | 143 | 10.01 kW | 1,108 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This First Solar Inc Series?
Related First Solar Inc power steps and black/silver trims consolidated into this First Solar Inc FS-370 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| First Solar Inc FS-367 | 67.5 W | 64.0 W | 60.5 V | 47.8 V | 9.38% |
| First Solar Inc FS-370 | 70.0 W | 66.4 W | 60.6 V | 48.1 V | 9.72% |
| First Solar Inc FS-372 | 72.5 W | 68.8 W | 61.4 V | 49.5 V | 10.07% |
How Many First Solar Inc FS-370 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for First Solar Inc FS-370 (60.6 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 65.26 V | 9 panels | 587.3 V | 15 panels |
| -10 C (14 F) | 64.23 V | 9 panels | 578.1 V | 15 panels |
| 0 C (32 F) | 63.19 V | 9 panels | 568.7 V | 15 panels |
| 25 C (77 F STC) | 60.6 V | 9 panels | 545.4 V | 16 panels |
Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-370?
Four comparable CEC modules such as Zhongshan Ruike New Energy Co Ltd RK-75-2 (75.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Zhongshan Ruike New Energy Co Ltd RK-75-2 Zhongshan Ruike New Energy Co Ltd |
75.0 W | +5.0 W | 58.5 V | 10.42% | 93.9% |
| Centrosolar America VS-140C1 Centrosolar America |
140.0 W | +70.0 W | 60.6 V | 12.89% | 92.7% |
| Miasole FLEX-03 120N Miasole |
115.1 W | +45.1 W | 37.8 V | 12.82% | 90.9% |
| Centrosolar America VS-140C2 Centrosolar America |
140.0 W | +70.0 W | 79.95 V | 12.89% | 92.9% |
What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-370?
Evaluate First Solar Inc FS-370 (70.0 W STC, 60.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-370 reaches 65.26 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 115 panels for an 8 kW build require 891 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 115 panels (891 sq ft).
- 2026 tax credit baseline: cash residential installs of First Solar Inc FS-370 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
First Solar Inc FS-370 8 kW Residential Fit
Needs 115 modules (891 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Zhongshan Ruike New Energy Co Ltd RK-75-2.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 66.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for First Solar Inc FS-370 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
Why is First Solar Inc FS-370 PTC wattage (66.4 W) lower than STC (70.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 66.4 W PTC (94.9% retention) across First Solar Inc FS-370's 0.72 m2 aperture.
Who should skip First Solar Inc FS-370 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 115 First Solar Inc FS-370 panels (891 sq ft) leave unusable roof gaps vs. Zhongshan Ruike New Energy Co Ltd RK-75-2.
What is the 1,000 V commercial string limit for First Solar Inc FS-370?
On 1,000 V commercial inverters at -10 C (64.23 V cold Voc), First Solar Inc FS-370 fits up to 15 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting First Solar Inc FS-370.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)