First Solar Inc FS-277 — CEC Solar Module Specifications

Manufacturer: First Solar Inc Registry: CEC Verified Engineering Specification

First Solar Inc FS-277 is a 77.5 W STC (74.6 W PTC) Thin Film solar module ranking #21,610 of 21,677 CEC listings (below all-CEC median; higher than 0.3% of peers). It delivers 10.76% efficiency, 93.0 V Voc at 25 C, and 100.75 V cold Voc at -10 C (5 panels max per 600 V string).

STC Wattage
77.5 W
PTC Wattage
74.6 W
Voc @ 25C
93.0 V
Efficiency
10.76%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does First Solar Inc FS-277 Compare Against Peer CEC Listings?

Engineering position of First Solar Inc FS-277 (77.5 W STC) vs. T-Solar Global TS97 across 106 CEC Thin Film solar modules.

Ranking #21,610 across 21,677 CEC solar panels (below all-CEC median; higher than 0.3% of peers), First Solar Inc FS-277 operates as a compact residential or specialty off-grid module sitting 40.0 W below the 117.5 W Thin Film median. Higher 93.0 V open-circuit voltage caps 600 V residential strings at 5 panels at 14 F (-10 C). With strong 96.3% PTC-to-STC heat retention (#14 of 21,677), 104 panels occupy 806 sq ft and offset roughly $2,017/yr at average US rates (or $3,411/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does First Solar Inc FS-277 Fall Across Listed CEC Models?

Plots First Solar Inc FS-277 at 77.5 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where First Solar Inc FS-277 (77.5 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCFirst Solar Inc FS: 77.5 W

What Dataset Percentiles Define First Solar Inc FS-277?

Benchmarks First Solar Inc FS-277 on STC wattage, thermal PTC/STC retention, and 10.76 aperture conversion efficiency against CEC peers.

First Solar Inc FS-277 Engineering BenchmarksPercentile comparison of First Solar Inc FS-277 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage77.5 WPTC/STC Retention96.3%Module Efficiency10.76%

What Do the Dataset Ranks Show for First Solar Inc FS-277?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for First Solar Inc FS-277 by First Solar Inc.

Rank #21,610 / 21,677

77.5 W STC · Higher Than 0.3%

77.5 W STC (-307.5 W vs all-CEC median) vs 117.5 W Thin Film median.

Eff #21,603

10.76% Aperture Efficiency

Power density 107.6 W/m2 (9.15 percentage points below 19.91% CEC median). PTC/STC ratio: 96.3% (rank #14).

NEC 690.7 Limit

5 Panels Max @ -10 C (600 V)

Cold Voc reaches 100.75 V at -10 C (503.8 V string) and 102.96 V at -20 C (5 max).

8 kW Reference Array

104 Panels = 8,060 W STC

Occupies 74.9 m2 (806 sq ft) producing 7,758 W PTC; NEC 690.8 OCPD floor is 1.89 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 93.0 * (1 + (-0.238/100) * (-10 - 25)) = 100.75 V | OCPD = 1.56 * 1.21 = 1.89 A

Inputs from CEC Modules.csv for First Solar Inc FS-277: Voc=93.0 V, beta_Voc=-0.238%/C, Isc=1.21 A, STC=77.5 W, Area=0.72 m2.

Result: 5 panels max on 600 V (503.8 V); 104 panels for 8 kW (806 sq ft).

What Are the Published CEC Specifications for First Solar Inc FS-277?

Laboratory test ratings recorded for First Solar Inc FS-277 (Thin Film) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for First Solar Inc FS-277.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 77.5 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 74.6 W (96.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 93.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 1.21 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 70.9 V / 1.09 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.238 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 10.76% (0.72 m2) Array roof footprint density
Cell Count & Technology 116 cells (Thin Film) Monofacial backsheet

How Many First Solar Inc FS-277 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (806 sq ft at 8 kW), and estimated Year-1 electric bill offset for First Solar Inc FS-277.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 78 6.04 kW 605 sq ft $1,512 $2,556
8 kW Class 104 8.06 kW 806 sq ft $2,017 $3,411
10 kW Class 130 10.07 kW 1,008 sq ft $2,520 $4,262

Which Sibling Wattage & Trim Variants Belong to This First Solar Inc Series?

Sibling wattage bins and frame colors grouped with First Solar Inc FS-277 under First Solar Inc to prevent duplicate spec pages.

Sibling CEC listings grouped into the First Solar Inc FS-277 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
First Solar Inc FS-275 75.0 W 72.2 W 92.0 V 69.4 V 10.42%
First Solar Inc FS-277 77.5 W 74.6 W 93.0 V 70.9 V 10.76%
First Solar Inc FS-280 80.0 W 76.9 W 91.5 V 71.2 V 11.11%

How Many First Solar Inc FS-277 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for First Solar Inc FS-277 (beta_Voc -0.238%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=93.0V and beta_Voc=-0.238%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 102.96 V 5 panels 514.8 V 9 panels
-10 C (14 F) 100.75 V 5 panels 503.8 V 9 panels
0 C (32 F) 98.53 V 6 panels 591.2 V 10 panels
25 C (77 F STC) 93.0 V 6 panels 558.0 V 10 panels

Which Cross-Brand Solar Modules Compare Closest to First Solar Inc FS-277?

Closest cross-brand CEC competitors to First Solar Inc FS-277 matched near 77.5 W STC and 93.0 V Voc, led by T-Solar Global TS97.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
T-Solar Global TS97
T-Solar Global
97.5 W +20.0 W 93.0 V 6.84% 92.9%
T-Solar Global TS102
T-Solar Global
102.5 W +25.0 W 93.0 V 7.19% 93.0%
Du Pont Apollo DA095-A2
Du Pont Apollo
95.0 W +17.5 W 100.0 V 6.17% 90.8%
Applied Materials 1/4 Size Single Junction Version 10
Applied Materials
116.0 W +38.5 W 96.2 V 8.11% 93.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for First Solar Inc FS-277?

Evaluate First Solar Inc FS-277 (77.5 W STC, 93.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), First Solar Inc FS-277 reaches 102.96 V per panel—exceeding 5 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 104 panels for an 8 kW build require 806 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 104 panels (806 sq ft).
  • 2026 tax credit baseline: cash residential installs of First Solar Inc FS-277 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

First Solar Inc FS-277 8 kW Residential Fit

Needs 104 modules (806 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 5 panels (-10 C) or 5 panels (-20 C), or compare T-Solar Global TS97.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 74.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for First Solar Inc FS-277 by First Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many First Solar Inc FS-277 panels fit on a 600 V winter solar string?

At -10 C (14 F), First Solar Inc FS-277 cold Voc rises from 93.0 V to 100.75 V (beta_Voc -0.238%/C), capping a 600 V string at 5 panels (503.8 V).

How much roof area does an 8 kW array of First Solar Inc FS-277 need?

An 8 kW DC system uses 104 First Solar Inc FS-277 modules (8,060 W STC / 7,758 W PTC), covering roughly 806 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does First Solar Inc FS-277 compare against T-Solar Global TS97?

First Solar Inc FS-277 outputs 77.5 W STC (93.0 V Voc, rank #21,610 of 21,677), while T-Solar Global TS97 delivers 97.5 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.