Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 is a 585.0 W STC (554.0 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.67% efficiency, 51.5 V Voc at 25 C, and 55.63 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 585.0 W
- PTC Wattage
- 554.0 W
- Voc @ 25C
- 51.5 V
- Efficiency
- 22.67%
How Does Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 Compare Against Peer CEC Listings?
How Chint New Energy Technology Co Ltd Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 handles rooftop heat (554.0 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 exhibits 14.36 A short-circuit current, requiring a 22.4 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #1,751 of 21,677 (175.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 36.1 m2 for an 8 kW system (18 panels for 10 kW). Higher 51.5 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 Fall Across Listed CEC Models?
Where Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 (585.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585?
Percentile placement of Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 across power density (226.7 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585?
Four critical engineering numbers homeowners and solar installers check first when reviewing Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 specifications.
Top 8.7% STC Output
585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.67% Aperture Efficiency
Power density 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.63 V at -10 C (556.3 V string) and 56.81 V at -20 C (10 max).
14 Panels = 8,190 W STC
Occupies 36.1 m2 (389 sq ft) producing 7,756 W PTC; NEC 690.8 OCPD floor is 22.4 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 51.5 * (1 + (-0.229/100) * (-10 - 25)) = 55.63 V | OCPD = 1.56 * 14.36 = 22.4 A
Inputs from CEC Modules.csv for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585: Voc=51.5 V, beta_Voc=-0.229%/C, Isc=14.36 A, STC=585.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (556.3 V); 14 panels for 8 kW (389 sq ft).
What Are the Published CEC Specifications for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 554.0 W (94.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 51.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.36 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 43.27 V / 13.52 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.229 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.67% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 (585.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.43 kW | 305 sq ft | $1,609 | $2,721 |
| 8 kW Class | 14 | 8.19 kW | 389 sq ft | $2,050 | $3,466 |
| 10 kW Class | 18 | 10.53 kW | 500 sq ft | $2,636 | $4,457 |
Which Sibling Wattage & Trim Variants Belong to This Chint New Energy Technology Co Ltd Series?
All closely matched Chint New Energy Technology Co Ltd wattages and cosmetic trims sharing the Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-575 | 575.0 W | 544.3 W | 51.1 V | 42.94 V | 22.29% |
| Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-580 | 580.0 W | 549.2 W | 51.3 V | 43.11 V | 22.48% |
| Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 | 585.0 W | 554.0 W | 51.5 V | 43.27 V | 22.67% |
| Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-590 | 590.0 W | 558.9 W | 51.7 V | 43.45 V | 22.87% |
| Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-595 | 595.0 W | 563.7 W | 51.9 V | 43.61 V | 23.06% |
How Many Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 Modules Fit in a Cold-Weather String?
Maximum series module counts for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.81 V | 10 panels | 568.1 V | 17 panels |
| -10 C (14 F) | 55.63 V | 10 panels | 556.3 V | 17 panels |
| 0 C (32 F) | 54.45 V | 11 panels | 599.0 V | 18 panels |
| 25 C (77 F STC) | 51.5 V | 11 panels | 566.5 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585?
Alternative CEC solar modules from competing brands near Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 (585.0 W), including CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-585.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-585 CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI |
585.0 W | Tie (0 W) | 51.5 V | 22.85% | 94.2% |
| Gautam Solar Pvt Ltd G2G1755-HAD Gautam Solar Pvt Ltd |
585.0 W | Tie (0 W) | 51.19 V | 22.79% | 95.1% |
| Gautam Solar Pvt Ltd G2X1755N-UHAD Gautam Solar Pvt Ltd |
585.0 W | Tie (0 W) | 51.19 V | 22.76% | 94.9% |
| CSI Solar Co Ltd CS6W-585TB-AG CSI Solar Co Ltd |
585.0 W | Tie (0 W) | 52.4 V | 23.31% | 95.0% |
What Are the Design Limits and Best-Fit Uses for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585?
Evaluate Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 (585.0 W STC, 51.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 reaches 56.81 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 8 kW Residential Fit
Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-585.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 554.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 by Chint New Energy Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 PTC wattage (554.0 W) lower than STC (585.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 554.0 W PTC (94.7% retention) across Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585's 2.58 m2 aperture.
Who should skip Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 panels (389 sq ft) leave unusable roof gaps vs. CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-585.
What is the 1,000 V commercial string limit for Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585?
On 1,000 V commercial inverters at -10 C (55.63 V cold Voc), Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 fits up to 17 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)