Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Sun Gold Power Inc: SGN10KHB-48 {208V} — CEC Inverter Specifications

Manufacturer: Sun Gold Power Inc Registry: CEC Verified Engineering Specification

Sun Gold Power Inc: SGN10KHB-48 {208V} outputs 10,186 W AC at 208 V, commercial single-phase (49.0 A continuous, 70 A OCPD), ranking #1,604 of 2,343 CEC inverters at 96.46% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
10,186 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
70 A (4 AWG Cu)
CEC Efficiency
96.46%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sun Gold Power Inc: SGN10KHB-48 {208V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,604), 200-480 V MPPT tracking, and panel fit for Sun Gold Power Inc: SGN10KHB-48 {208V}.

Operating at 208 V, commercial single-phase, Sun Gold Power Inc: SGN10KHB-48 {208V} converts DC array energy at 96.46% CEC weighted efficiency (below overall CEC median; higher than 30.6% of peers) with a 480 V max DC input and 29.3331 A max input current for NEC 690.7 string safety. Compare this 10,186 W hybrid battery-capable inverter directly with Delta Electronics: S12_BDI {208V} (10,057 W). Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.

Where Does Sun Gold Power Inc: SGN10KHB-48 {208V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Sun Gold Power Inc: SGN10KHB-48 {208V} at 10,186 W continuous AC output. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Sun Gold Power Inc: SGN10KHB-48 {208V} (10,186 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSun Gold Power Inc: 10,186 W

What Dataset Percentiles Define Sun Gold Power Inc: SGN10KHB-48 {208V}?

Dataset percentiles comparing Sun Gold Power Inc: SGN10KHB-48 {208V} against 2,343 certified grid-support inverters nationwide. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sun Gold Power Inc: SGN10KHB-48 {208V} Technical ThresholdsPercentile comparison for Sun Gold Power Inc: SGN10KHB-48 {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output10,186 WCEC Efficiency96.46%Backfeed Breaker70 A

What Do the Dataset Ranks Show for Sun Gold Power Inc: SGN10KHB-48 {208V}?

Engineering highlights for Sun Gold Power Inc: SGN10KHB-48 {208V} covering efficiency, 4 AWG Cu feeder, and panel compatibility.

Eff #1,604 / 2,343

96.46% CEC Weighted Efficiency

+0.05 pts vs the 96.41% 208 V median; overall power rank #837 (10,186 W, top 35.8%; higher than 64.2% of peers).

NEC 705.12 Check

70 A Required Backfeed OCPD

125% x 49.0 A = 61.2 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; listed since 2025-09-02 (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 10185.8W / 208 V -> 49.0 A | Breaker >= 1.25 * 49.0 = 61.2 A -> 70 A

CEC Inverters.csv for Sun Gold Power Inc: SGN10KHB-48 {208V}: Paco=10185.8 W, Vac=208 V, Vdcmax=480.0 V, Eff=96.46%.

Result: Min 70 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Sun Gold Power Inc: SGN10KHB-48 {208V}?

California Energy Commission Solar Equipment List parameters for Sun Gold Power Inc: SGN10KHB-48 {208V} (hybrid battery-capable inverter) interconnection.

Official California Energy Commission (NREL SAM) test parameters for Sun Gold Power Inc: SGN10KHB-48 {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 10,186 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 29.3331 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.46% Calculated AC/DC conversion ratio from CEC test protocol
CEC Listing Date & Hybrid 2025-09-02 / Hybrid: Yes (Battery Capable) Utility interconnection approval metadata

What Switchgear Limits Apply to Sun Gold Power Inc: SGN10KHB-48 {208V} (208 V, commercial single-phase)?

Panelboard and switchgear backfeed allowances for Sun Gold Power Inc: SGN10KHB-48 {208V} (70 A OCPD). Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Evaluates Sun Gold Power Inc: SGN10KHB-48 {208V} (70 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 70 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 70 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 70 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 70 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 70 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Sun Gold Power Inc: SGN10KHB-48 {208V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Sun Gold Power Inc: SGN10KHB-48 {208V}. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Sun Gold Power Inc: SGN10KHB-48 {208V}?

Four alternative CEC inverters matched to Sun Gold Power Inc: SGN10KHB-48 {208V} (10,186 W AC), led by Delta Electronics: S12_BDI {208V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Delta Electronics: S12_BDI {208V}
Delta Electronics
10,057 W -129 W 208.0 V 480.0 V 96.7%
Altenergy Power System Inc: ELS-114 {208V}
Altenergy Power System Inc
10,011 W -175 W 208.0 V 60.0 V 92.83%
EG4 Electronics LLC: 18KPV-12LV {208V}
EG4 Electronics LLC
10,499 W +313 W 208.0 V 480.0 V 96.07%
Chint Power Systems America: CPS ECH96KTL/US {208V}
Chint Power Systems America
9,550 W -636 W 208.0 V 480.0 V 96.73%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Sun Gold Power Inc: SGN10KHB-48 {208V}?

Check Sun Gold Power Inc: SGN10KHB-48 {208V} (10,186 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Sun Gold Power Inc: SGN10KHB-48 {208V}.

Sun Gold Power Inc: SGN10KHB-48 {208V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (49.0 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.46%) and MPPT window (200-480 V) directly against Delta Electronics: S12_BDI {208V} (10,057 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sun Gold Power Inc: SGN10KHB-48 {208V} by Sun Gold Power Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Sun Gold Power Inc: SGN10KHB-48 {208V} require?

At 10,186 W continuous AC (208 V, commercial single-phase), continuous current is 49.0 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Sun Gold Power Inc: SGN10KHB-48 {208V} require?

At 10,186 W AC and 208 V, commercial single-phase, continuous line current is 49.0 A, requiring a 70 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Sun Gold Power Inc: SGN10KHB-48 {208V} compare to Delta Electronics: S12_BDI {208V}?

Sun Gold Power Inc: SGN10KHB-48 {208V} delivers 10,186 W AC at 96.46% CEC efficiency with a 480 V DC ceiling, while Delta Electronics: S12_BDI {208V} outputs 10,057 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.