Sun Gold Power Inc: SGS-12K18MAX {240V} outputs 11,990 W AC at 240 V (50.0 A continuous, 70 A OCPD), ranking #2,190 of 2,343 CEC inverters at 95.41% efficiency with a 275-450 V MPPT window and 450 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- AC Output (Paco)
- 11,990 W
- AC Voltage
- 240 V
- Min PV Breaker
- 70 A (4 AWG Cu)
- CEC Efficiency
- 95.41%
How Does Sun Gold Power Inc: SGS-12K18MAX {240V} Compare Against Peer CEC Listings?
CEC efficiency rank (#2,190), 275-450 V MPPT tracking, and panel fit for Sun Gold Power Inc: SGS-12K18MAX {240V}.
Sun Gold Power Inc: SGS-12K18MAX {240V} from Sun Gold Power Inc outputs 50.0 A continuous AC at 240 V (11,990 W AC, rank #735). Paired with 4 AWG Cu conductors and a 70 A OCPD, its 95.41% CEC efficiency compares closely with Chint Power Systems America: CPS ECH12KTL/US {240V} (11,990 W). Keep NEC 690.7 winter string Voc below 450 V DC.
Where Does Sun Gold Power Inc: SGS-12K18MAX {240V} Fall Across Listed CEC Models?
CEC inverter wattage histogram highlighting Sun Gold Power Inc: SGS-12K18MAX {240V} at 11,990 W continuous AC output. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Dataset Percentiles Define Sun Gold Power Inc: SGS-12K18MAX {240V}?
Dataset percentiles comparing Sun Gold Power Inc: SGS-12K18MAX {240V} against 2,343 certified grid-support inverters nationwide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for Sun Gold Power Inc: SGS-12K18MAX {240V}?
Engineering highlights for Sun Gold Power Inc: SGS-12K18MAX {240V} covering efficiency, 4 AWG Cu feeder, and panel compatibility.
95.41% CEC Weighted Efficiency
-1.27 pts vs the 96.68% 240 V median; overall power rank #735 (11,990 W, top 31.4%; higher than 68.6% of peers).
70 A Required Backfeed OCPD
125% x 50.0 A = 62.5 A -> 70 A standard OCPD using 4 AWG Cu (75 C).
275 V - 450 V (Max 450 V DC)
Tracking span of 175.0 V; active in CEC directory (hybrid battery-capable inverter).
Needs Derate / Tap 705.11
200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.
NEC 705.12 Backfeed OCPD & 120% Busbar Formula
I_cont = 11990.0W / 240 V -> 50.0 A | Breaker >= 1.25 * 50.0 = 62.5 A -> 70 A
CEC Inverters.csv for Sun Gold Power Inc: SGS-12K18MAX {240V}: Paco=11990.0 W, Vac=240 V, Vdcmax=450.0 V, Eff=95.41%.
Result: Min 70 A breaker & 4 AWG Cu (75 C); 200A Bus / 200A Main: Needs Derate / Tap 705.11.
What Are the Published CEC Specifications for Sun Gold Power Inc: SGS-12K18MAX {240V}?
California Energy Commission Solar Equipment List parameters for Sun Gold Power Inc: SGS-12K18MAX {240V} (hybrid battery-capable inverter) interconnection.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Max Continuous AC Power (Paco) | 11,990 W | Determines required backfeed OCPD size via 125% continuous rule |
| Nominal AC Voltage (Vac) | 240 V | 240V split-phase residential vs. 208V/480V/MV commercial |
| Max DC Input Voltage (Vdcmax) | 450 V | Hard ceiling for cold-weather PV string Voc under NEC 690.7 |
| MPPT Operating Range | 275 V - 450 V | Optimal DC string Vmp window for full power harvest |
| Max Input DC Current (Idcmax) | 34.6669 A | Used to verify parallel string combiner limits |
| CEC Weighted Efficiency | 95.41% | Calculated AC/DC conversion ratio from CEC test protocol |
| Inverter Topology | Hybrid: Yes (Battery Capable) | CEC Solar Equipment List grid-support certification |
Can a Residential Panel Meet 120% Busbar Limits for Sun Gold Power Inc: SGS-12K18MAX {240V}?
Panelboard and switchgear backfeed allowances for Sun Gold Power Inc: SGS-12K18MAX {240V} (70 A OCPD). Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
| Panel Configuration | 120% Max Backfeed | Required PV OCPD | Compliance Verdict |
|---|---|---|---|
| 100A Bus / 100A Main | 20 A | 70 A | Needs Derate / Tap 705.11 |
| 150A Bus / 150A Main | 30 A | 70 A | Needs Derate / Tap 705.11 |
| 200A Bus / 200A Main | 40 A | 70 A | Needs Derate / Tap 705.11 |
| 200A Bus / 175A Main | 65 A | 70 A | Needs Derate / Tap 705.11 |
| 225A Bus / 200A Main | 70 A | 70 A | PASS (120% Rule) |
Which CEC PV Module Strings Pair With Sun Gold Power Inc: SGS-12K18MAX {240V}?
Representative PV panel pairings verified under NEC 690.7 cold Voc for Sun Gold Power Inc: SGS-12K18MAX {240V}. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| CEC Module | STC (W) | -10 C Voc | Valid String Range | Max String DC |
|---|---|---|---|---|
| AXITEC AC-590TGB/144TS | 590.0 W | 56.24 V | 7 to 8 panels | 4.72 kW |
| Aptos Solar Technology LLC DNA-108-MFN10-440W | 440.0 W | 42.15 V | 9 to 10 panels | 4.4 kW |
| Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF | 425.0 W | 44.75 V | 8 to 10 panels | 4.25 kW |
| CSI Solar Co Ltd CS6P-200P | 200.0 W | 40.6 V | 10 to 11 panels | 2.2 kW |
Which Competing Grid-Support Inverters Compare to Sun Gold Power Inc: SGS-12K18MAX {240V}?
Four alternative CEC inverters matched to Sun Gold Power Inc: SGS-12K18MAX {240V} (11,990 W AC), led by Chint Power Systems America: CPS ECH12KTL/US {240V}.
| Alternative Inverter | AC Output | Delta | Vac | Max DC | CEC Eff |
|---|---|---|---|---|---|
| Chint Power Systems America: CPS ECH12KTL/US {240V} Chint Power Systems America |
11,990 W | Tie (0 W) | 240.0 V | 480.0 V | 96.59% |
| Amensolar Ess Co Ltd: N3H-X12US {240V} Amensolar Ess Co Ltd |
12,214 W | +224 W | 240.0 V | 430.0 V | 96.17% |
| Delta Electronics: S12_BDI {240V} Delta Electronics |
11,589 W | -401 W | 240.0 V | 480.0 V | 96.99% |
| Base Power Inc: MIN 11400TL-XH-US {240V} Base Power Inc |
11,520 W | -470 W | 240.0 V | 480.0 V | 97.76% |
What Are the Interconnection Limits and Best-Fit Uses for Sun Gold Power Inc: SGS-12K18MAX {240V}?
Check Sun Gold Power Inc: SGS-12K18MAX {240V} (11,990 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.
- Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
- Busbar 120% limit: Its 70 A backfeed breaker exceeds a 200A/200A panel's 40 A ceiling, requiring a 175 A main derate, 225 A busbar, or NEC 705.11 tap.
- Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 450 V DC on Sun Gold Power Inc: SGS-12K18MAX {240V}.
Sun Gold Power Inc: SGS-12K18MAX {240V} Panel & Wire Spec
Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (50.0 A continuous).
Alternative Inverter Comparison
Compare efficiency (95.41%) and MPPT window (275-450 V) directly against Chint Power Systems America: CPS ECH12KTL/US {240V} (11,990 W).
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Answers for Sun Gold Power Inc: SGS-12K18MAX {240V} by Sun Gold Power Inc covering breaker sizing, MPPT limits, and 240 V interconnection.
What breaker and wire size does Sun Gold Power Inc: SGS-12K18MAX {240V} require?
At 11,990 W continuous AC (240 V), continuous current is 50.0 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.
Does Sun Gold Power Inc: SGS-12K18MAX {240V} fit a 200 A main panel under the 120% busbar rule?
A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 70 A at 240 V means Needs Derate / Tap 705.11.
How does Sun Gold Power Inc: SGS-12K18MAX {240V} compare to Chint Power Systems America: CPS ECH12KTL/US {240V}?
Sun Gold Power Inc: SGS-12K18MAX {240V} delivers 11,990 W AC at 95.41% CEC efficiency with a 450 V DC ceiling, while Chint Power Systems America: CPS ECH12KTL/US {240V} outputs 11,990 W at 240 V.
Sources
- CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)