Skip to main content
WireAndSun
Calculators
CEC Grid-Support Inverter

Sun Gold Power Inc: SGN-11K15PRO {208V} — CEC Inverter Specifications

Manufacturer: Sun Gold Power Inc Registry: CEC Verified Engineering Specification

Sun Gold Power Inc: SGN-11K15PRO {208V} outputs 11,609 W AC at 208 V, commercial single-phase (55.8 A continuous, 70 A OCPD), ranking #1,604 of 2,343 CEC inverters at 96.46% efficiency with a 200-480 V MPPT window and 480 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
11,609 W
AC Voltage
208 V, commercial single-phase
Min PV Breaker
70 A (4 AWG Cu)
CEC Efficiency
96.46%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sun Gold Power Inc: SGN-11K15PRO {208V} Compare Against Peer CEC Listings?

How Sun Gold Power Inc Sun Gold Power Inc: SGN-11K15PRO {208V} compares on 96.46% efficiency, MPPT span, and 120% busbar interconnection.

With a 200-480 V MPPT tracking band and 480 V DC ceiling, Sun Gold Power Inc: SGN-11K15PRO {208V} handles 11,609 W continuous AC (6,609 W above the 5,000 W 208 V median). Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap. Installers comparing Sun Gold Power Inc against EcoFlow Inc: EF-PCS-24 {208V 115kW} (11,444 W) should verify whether active in CEC directory grid-support firmware meets local IEEE 1547 utility rules.

Where Does Sun Gold Power Inc: SGN-11K15PRO {208V} Fall Across Listed CEC Models?

Position of Sun Gold Power Inc: SGN-11K15PRO {208V} (11,609 W AC) relative to the 7,680 W CEC median inverter.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Sun Gold Power Inc: SGN-11K15PRO {208V} (11,609 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSun Gold Power Inc: 11,609 W

What Dataset Percentiles Define Sun Gold Power Inc: SGN-11K15PRO {208V}?

Percentile placement of Sun Gold Power Inc: SGN-11K15PRO {208V} across AC power class, conversion efficiency, and backfeed breaker size.

Sun Gold Power Inc: SGN-11K15PRO {208V} Technical ThresholdsPercentile comparison for Sun Gold Power Inc: SGN-11K15PRO {208V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output11,609 WCEC Efficiency96.46%Backfeed Breaker70 A

What Do the Dataset Ranks Show for Sun Gold Power Inc: SGN-11K15PRO {208V}?

Primary electrical sizing limits, efficiency ranks, and NEC 705.12 / 690.7 thresholds for Sun Gold Power Inc: SGN-11K15PRO {208V}.

Eff #1,604 / 2,343

96.46% CEC Weighted Efficiency

+0.05 pts vs the 96.41% 208 V median; overall power rank #750 (11,609 W, top 32.1%; higher than 67.9% of peers).

NEC 705.12 Check

70 A Required Backfeed OCPD

125% x 55.8 A = 69.8 A -> 70 A standard OCPD using 4 AWG Cu (75 C).

MPPT Window

200 V - 480 V (Max 480 V DC)

Tracking span of 280.0 V; active in CEC directory (hybrid battery-capable inverter).

Commercial / 3-Phase Fit

PASS (120% Commercial Busbar)

Evaluated for 208 V, commercial single-phase switchgear (200A Bus / 200A Main (208V) to 1,200A Bus / 1,200A Main (208V)) under NEC 705.12 / 705.11.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 11608.8W / 208 V -> 55.8 A | Breaker >= 1.25 * 55.8 = 69.8 A -> 70 A

CEC Inverters.csv for Sun Gold Power Inc: SGN-11K15PRO {208V}: Paco=11608.8 W, Vac=208 V, Vdcmax=480.0 V, Eff=96.46%.

Result: Min 70 A breaker & 4 AWG Cu (75 C); 1,200A Bus / 1,200A Main (208V): PASS (120% Commercial Busbar).

What Are the Published CEC Specifications for Sun Gold Power Inc: SGN-11K15PRO {208V}?

Official California Energy Commission electrical test parameters, AC voltage, and DC limits for Sun Gold Power Inc: SGN-11K15PRO {208V}.

Official California Energy Commission (NREL SAM) test parameters for Sun Gold Power Inc: SGN-11K15PRO {208V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 11,609 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 208 V, commercial single-phase 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 480 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 200 V - 480 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 33.4308 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.46% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: Yes (Battery Capable) CEC Solar Equipment List grid-support certification

What Switchgear Limits Apply to Sun Gold Power Inc: SGN-11K15PRO {208V} (208 V, commercial single-phase)?

Check whether Sun Gold Power Inc: SGN-11K15PRO {208V} (70 A breaker) fits without main breaker derate or supply-side taps.

Evaluates Sun Gold Power Inc: SGN-11K15PRO {208V} (70 A required OCPD at 208 V, commercial single-phase) across standard distribution busbars.
Switchboard / Interconnect120% Max BackfeedRequired PV OCPDCompliance Verdict
200A Bus / 200A Main (208V) 40 A 70 A Supply-Side Tap (705.11) / Dedicated Switchboard
400A Bus / 400A Main (208V) 80 A 70 A PASS (120% Commercial Busbar)
600A Bus / 600A Main (208V) 120 A 70 A PASS (120% Commercial Busbar)
800A Bus / 800A Main (208V) 160 A 70 A PASS (120% Commercial Busbar)
1,200A Bus / 1,200A Main (208V) 240 A 70 A PASS (120% Commercial Busbar)

Which CEC PV Module Strings Pair With Sun Gold Power Inc: SGN-11K15PRO {208V}?

Verified cold-weather (-10 C) series module counts matched to Sun Gold Power Inc: SGN-11K15PRO {208V}'s 480 V DC ceiling.

Sampled CEC PV modules aligned within 200.0-480.0 V MPPT and 480.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
AXITEC AC-590TGB/144TS 590.0 W 56.24 V 5 to 8 panels 4.72 kW
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 6 to 11 panels 4.84 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 6 to 10 panels 4.25 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 7 to 11 panels 2.2 kW

Which Competing Grid-Support Inverters Compare to Sun Gold Power Inc: SGN-11K15PRO {208V}?

Alternative CEC inverters comparable to Sun Gold Power Inc: SGN-11K15PRO {208V}, including EcoFlow Inc: EF-PCS-24 {208V 115kW} (11,444 W) at 208 V, commercial single-phase.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
EcoFlow Inc: EF-PCS-24 {208V 115kW}
EcoFlow Inc
11,444 W -165 W 208.0 V 480.0 V 96.52%
Chint Power Systems America: CPS ECH114KTL/US {208V}
Chint Power Systems America
11,350 W -259 W 208.0 V 480.0 V 96.63%
EG4 Electronics LLC: IV-13000-HYB-AW-FX-xx {208V}
EG4 Electronics LLC
11,325 W -284 W 208.0 V 440.0 V 96.79%
Chint Power Systems America: CPS ECH12KTL/US {208V}
Chint Power Systems America
12,000 W +391 W 208.0 V 480.0 V 96.63%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Sun Gold Power Inc: SGN-11K15PRO {208V}?

Check Sun Gold Power Inc: SGN-11K15PRO {208V} (11,609 W AC, 70 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Commercial 208 V, commercial single-phase switchgear interconnection uses 1,200A Bus / 1,200A Main (208V) or NEC 705.11 supply-side tap.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 480 V DC on Sun Gold Power Inc: SGN-11K15PRO {208V}.

Sun Gold Power Inc: SGN-11K15PRO {208V} Panel & Wire Spec

Size 75 C copper conductors at 4 AWG Cu on a 70 A OCPD breaker (55.8 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.46%) and MPPT window (200-480 V) directly against EcoFlow Inc: EF-PCS-24 {208V 115kW} (11,444 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Sun Gold Power Inc: SGN-11K15PRO {208V} by Sun Gold Power Inc covering breaker sizing, MPPT limits, and 208 V, commercial single-phase interconnection.

What breaker and wire size does Sun Gold Power Inc: SGN-11K15PRO {208V} require?

At 11,609 W continuous AC (208 V, commercial single-phase), continuous current is 55.8 A; 125% NEC 690.8/705.12 sizing requires a 70 A breaker and 4 AWG Cu (75 C) wire.

What commercial switchgear or feeder sizing does Sun Gold Power Inc: SGN-11K15PRO {208V} require?

At 11,609 W AC and 208 V, commercial single-phase, continuous line current is 55.8 A, requiring a 70 A OCPD and 1,200A Bus / 1,200A Main (208V) or NEC 705.11 interconnection.

How does Sun Gold Power Inc: SGN-11K15PRO {208V} compare to EcoFlow Inc: EF-PCS-24 {208V 115kW}?

Sun Gold Power Inc: SGN-11K15PRO {208V} delivers 11,609 W AC at 96.46% CEC efficiency with a 480 V DC ceiling, while EcoFlow Inc: EF-PCS-24 {208V 115kW} outputs 11,444 W at 208 V, commercial single-phase.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.