Solvari Inc: SVR-A11-240 {240V} — CEC Inverter Specifications

Manufacturer: Solvari Inc Registry: CEC Verified Engineering Specification

Solvari Inc: SVR-A11-240 {240V} outputs 398 W AC at 240 V (1.7 A continuous, 15 A OCPD), ranking #1,785 of 2,343 CEC inverters at 96.28% efficiency with a 22-55 V MPPT window and 55 V DC limit. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

AC Output (Paco)
398 W
AC Voltage
240 V
Min PV Breaker
15 A (14 AWG Cu)
CEC Efficiency
96.28%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solvari Inc: SVR-A11-240 {240V} Compare Against Peer CEC Listings?

CEC efficiency rank (#1,785), 22-55 V MPPT tracking, and panel fit for Solvari Inc: SVR-A11-240 {240V}. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Operating at 240 V, Solvari Inc: SVR-A11-240 {240V} converts DC array energy at 96.28% CEC weighted efficiency (below overall CEC median; higher than 23.3% of peers) with a 55 V max DC input and 11.8109 A max input current for NEC 690.7 string safety. Compare this 398 W grid-tied PV inverter directly with Aptos Solar Technology LLC: MAC-400 {240V} (382 W). Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.

Where Does Solvari Inc: SVR-A11-240 {240V} Fall Across Listed CEC Models?

CEC inverter wattage histogram highlighting Solvari Inc: SVR-A11-240 {240V} at 398 W continuous AC output. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

AC Power Distribution Across Listed CEC Inverters (up to 25 kW)Shows where Solvari Inc: SVR-A11-240 {240V} (398 W AC) sits across CEC inverters. 190-2258 W AC: 584 entries1902258-4325 W AC: 158 entries4325-6392 W AC: 259 entries6392-8460 W AC: 270 entries63928460-10528 W AC: 258 entries10528-12595 W AC: 116 entries12595-14662 W AC: 17 entries1259514662-16730 W AC: 37 entries16730-18798 W AC: 7 entries18798-20865 W AC: 11 entries1879820865-22932 W AC: 5 entries22932-25000 W AC: 26 entries22932Median 7,680 W ACSolvari Inc: SVR-A: 398 W

What Dataset Percentiles Define Solvari Inc: SVR-A11-240 {240V}?

Dataset percentiles comparing Solvari Inc: SVR-A11-240 {240V} against 2,343 certified grid-support inverters nationwide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Solvari Inc: SVR-A11-240 {240V} Technical ThresholdsPercentile comparison for Solvari Inc: SVR-A11-240 {240V} AC output, weighted CEC efficiency, and OCPD sizing. 0% (Low)50% Median100% (Top)Rated AC Output398 WCEC Efficiency96.28%Backfeed Breaker15 A

What Do the Dataset Ranks Show for Solvari Inc: SVR-A11-240 {240V}?

Engineering highlights for Solvari Inc: SVR-A11-240 {240V} covering efficiency, 14 AWG Cu feeder, and panel compatibility. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Eff #1,785 / 2,343

96.28% CEC Weighted Efficiency

-0.40 pts vs the 96.68% 240 V median; overall power rank #1,986 (398 W, below CEC median; higher than 15.2% of peers).

NEC 705.12 Check

15 A Required Backfeed OCPD

125% x 1.7 A = 2.1 A -> 15 A standard OCPD using 14 AWG Cu (75 C).

MPPT Window

22 V - 55 V (Max 55 V DC)

Tracking span of 33.0 V; active in CEC directory (grid-tied PV inverter).

Panel Fit (240V)

PASS (120% Rule)

200A/200A panel allows 40A PV backfeed; 200A/175A derate allows 65A; 225A/200A allows 70A.

NEC 705.12 Backfeed OCPD & 120% Busbar Formula

I_cont = 398.0W / 240 V -> 1.7 A | Breaker >= 1.25 * 1.7 = 2.1 A -> 15 A

CEC Inverters.csv for Solvari Inc: SVR-A11-240 {240V}: Paco=398.0 W, Vac=240 V, Vdcmax=55.0 V, Eff=96.28%.

Result: Min 15 A breaker & 14 AWG Cu (75 C); 200A Bus / 200A Main: PASS (120% Rule).

What Are the Published CEC Specifications for Solvari Inc: SVR-A11-240 {240V}?

California Energy Commission Solar Equipment List parameters for Solvari Inc: SVR-A11-240 {240V} (grid-tied PV inverter) interconnection. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Solvari Inc: SVR-A11-240 {240V}.
ParameterMeasured / Listed ValueEngineering Significance
Max Continuous AC Power (Paco) 398 W Determines required backfeed OCPD size via 125% continuous rule
Nominal AC Voltage (Vac) 240 V 240V split-phase residential vs. 208V/480V/MV commercial
Max DC Input Voltage (Vdcmax) 55 V Hard ceiling for cold-weather PV string Voc under NEC 690.7
MPPT Operating Range 22 V - 55 V Optimal DC string Vmp window for full power harvest
Max Input DC Current (Idcmax) 11.8109 A Used to verify parallel string combiner limits
CEC Weighted Efficiency 96.28% Calculated AC/DC conversion ratio from CEC test protocol
Inverter Topology Hybrid: No (Grid-Tied PV) CEC Solar Equipment List grid-support certification

Can a Residential Panel Meet 120% Busbar Limits for Solvari Inc: SVR-A11-240 {240V}?

Panelboard and switchgear backfeed allowances for Solvari Inc: SVR-A11-240 {240V} (15 A OCPD). Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Evaluates Solvari Inc: SVR-A11-240 {240V} (15 A required OCPD at 240 V) across standard distribution busbars.
Panel Configuration120% Max BackfeedRequired PV OCPDCompliance Verdict
100A Bus / 100A Main 20 A 15 A PASS (120% Rule)
150A Bus / 150A Main 30 A 15 A PASS (120% Rule)
200A Bus / 200A Main 40 A 15 A PASS (120% Rule)
200A Bus / 175A Main 65 A 15 A PASS (120% Rule)
225A Bus / 200A Main 70 A 15 A PASS (120% Rule)

Which CEC PV Module Strings Pair With Solvari Inc: SVR-A11-240 {240V}?

Representative PV panel pairings verified under NEC 690.7 cold Voc for Solvari Inc: SVR-A11-240 {240V}. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sampled CEC PV modules aligned within 22.0-55.0 V MPPT and 55.0 V max DC at -10 C.
CEC ModuleSTC (W)-10 C VocValid String RangeMax String DC
Aptos Solar Technology LLC DNA-108-MFN10-440W 440.0 W 42.15 V 1 panel (micro/module) 0.44 kW
Boviet Solar Technology Co Ltd BVM7610M-425-H-HC-BF 425.0 W 44.75 V 1 panel (micro/module) 0.42 kW
CSI Solar Co Ltd CS6P-200P 200.0 W 40.6 V 1 panel (micro/module) 0.2 kW
Chint New Energy Technology Co Ltd CHSM72M(DG)/F-BH-515 515.0 W 53.76 V 1 panel (micro/module) 0.52 kW

Which Competing Grid-Support Inverters Compare to Solvari Inc: SVR-A11-240 {240V}?

Four alternative CEC inverters matched to Solvari Inc: SVR-A11-240 {240V} (398 W AC), led by Aptos Solar Technology LLC: MAC-400 {240V}.

Alternative CEC inverters at comparable AC output power and voltage class.
Alternative InverterAC OutputDeltaVacMax DCCEC Eff
Aptos Solar Technology LLC: MAC-400 {240V}
Aptos Solar Technology LLC
382 W -16 W 240.0 V 48.0 V 96.52%
Aptos Solar Technology LLC: MAC-400R {240V}
Aptos Solar Technology LLC
382 W -16 W 240.0 V 48.0 V 96.52%
Chilicon Power LLC: CP-250E-60/72-208/240-MC4 {240V}
Chilicon Power LLC
289 W -109 W 240.0 V 32.0 V 95.41%
Altenergy Power System Inc: YC600 {240V}
Altenergy Power System Inc
550 W +152 W 240.0 V 45.0 V 96.51%
What to Check & Best-Fit Scenarios

What Are the Interconnection Limits and Best-Fit Uses for Solvari Inc: SVR-A11-240 {240V}?

Check Solvari Inc: SVR-A11-240 {240V} (398 W AC, 15 A OCPD) against your main panel busbar, winter string Voc, and IEEE 1547 outage rules.

  • Anti-islanding shutdown: grid-tied inverters shut off within 2 seconds during blackouts under IEEE 1547 unless paired with a battery microgrid interconnect.
  • Busbar 120% limit: Module-level microinverter output eliminates high-voltage DC rooftop strings and connects via a 240V AC trunk circuit.
  • Cold Voc hard ceiling: never allow winter open-circuit PV string voltage to exceed 55 V DC on Solvari Inc: SVR-A11-240 {240V}.

Solvari Inc: SVR-A11-240 {240V} Panel & Wire Spec

Size 75 C copper conductors at 14 AWG Cu on a 15 A OCPD breaker (1.7 A continuous).

Alternative Inverter Comparison

Compare efficiency (96.28%) and MPPT window (22-55 V) directly against Aptos Solar Technology LLC: MAC-400 {240V} (382 W).

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Answers for Solvari Inc: SVR-A11-240 {240V} by Solvari Inc covering breaker sizing, MPPT limits, and 240 V interconnection.

What breaker and wire size does Solvari Inc: SVR-A11-240 {240V} require?

At 398 W continuous AC (240 V), continuous current is 1.7 A; 125% NEC 690.8/705.12 sizing requires a 15 A breaker and 14 AWG Cu (75 C) wire.

Does Solvari Inc: SVR-A11-240 {240V} fit a 200 A main panel under the 120% busbar rule?

A 200 A busbar with a 200 A main allows 40 A of solar backfeed. Requiring 15 A at 240 V means PASS (120% Rule).

How does Solvari Inc: SVR-A11-240 {240V} compare to Aptos Solar Technology LLC: MAC-400 {240V}?

Solvari Inc: SVR-A11-240 {240V} delivers 398 W AC at 96.28% CEC efficiency with a 55 V DC ceiling, while Aptos Solar Technology LLC: MAC-400 {240V} outputs 382 W at 240 V.

Sources

  1. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.